Connect the mask system to the free end of the long air tubing. The final assembly should look like this:

Switch on the HumidAire and the VPAP Adapt SV.

WARNING

Make sure that the power cords and plugs are in good condition and the equipment is not damaged.

Perform the Air Circuit Learn function (see page 22).

For information about filling and maintaining your humidifier, refer to the HumidAire User’s Manual.

The VPAP Adapt SV is now ready for use with the HumidAire. See “Starting Treatment” on page 17.

CAUTIONS

! Set up the HumidAire and the VPAP Adapt SV unit so that the tubing to the mask runs higher than the machines. This will prevent condensation build-up.

If condensation appears in the mask, turn the humidifier settings down.

14

Image 20
Contents Vpap Adapt SV USA ENG Reorder number 26869/2 06 Page Contents Daily Weekly Periodically Air Filter Introduction Vpap Adapt SVUser/Owner Responsibility DefinitionsPage Page Page Quick Setup Guide Page Vpap Adapt SV System Vpap Adapt SV ComponentsMasks Air tubing fully assembledConnect the power cord Assembling the Vpap Adapt SV SystemAttach the mask to the air tubing Connecting a Humidifier HumidifiersHumidAire HumidAire 2i attached to the Vpap Adapt SVHumidAire Page ResLink Anti-bacterial FilterUsing DC Power to Run the Vpap Adapt SV Supplemental OxygenUsing the Vpap Adapt SV Standby ModeStarting Treatment Stopping TreatmentControl Panel Functions LCD screenStart/Stop key Up/Down keyAdjusting Settings Alarm LEDs and Alarm MuteLeft key green Right key redYou wish to change the setting for the mask you are using ExampleNavigating the Patient menu Using the Vpap Adapt SV MenusLearn Circuit Settings MenuMask Ramp Cpap mode only Results MenuSmartStop Leak AlertOptions Menu Treatment Screens Servicing MenuPage Alarms Low Mask Pressure AlarmIf a low pressure alarm sounds Triggered byHigh Leak Alarm Power Fail AlarmHigh Pressure Alarm Insufficient Pressure Support Alarm Flow Blocked AlarmIf an insufficient pressure support alarm sounds If a flow blocked alarm soundsPage Weekly Cleaning and MaintenanceDaily Air tubing assembly removed for cleaning PeriodicallyAir Filter ServicingHypoallergenic Air Filter Fitting the filterPage Troubleshooting Unusual mannerPage Alarms GlossaryPage Technical Specifications Inspiratory Trigger Characteristics IEC 601-1 classificationsPage Mask setting flow/pressure characteristics Glossary of symbolsEmissions test Compliance Next Portable and mobile RF communications Separation distance according to frequency of transmitter Limited Warranty Page Index