ResMed Adapt SV System manual Mask setting flow/pressure characteristics, Glossary of symbols

Page 48

Mask setting: flow/pressure characteristics

 

60

 

50

(L/min)Flow

40

30

 

20

10

0

0

5

10

15

20

25

Pressure (cm H2O)

Glossary of symbols

Read the operating manual before using

Type CF equipment

AC switch

Class II equipment

Full Face Activa

Ultra

Vista

42

Image 48
Contents Vpap Adapt SV USA ENG Reorder number 26869/2 06 Page Contents Daily Weekly Periodically Air Filter Introduction Vpap Adapt SVUser/Owner Responsibility DefinitionsPage Page Page Quick Setup Guide Page Vpap Adapt SV System Vpap Adapt SV ComponentsMasks Air tubing fully assembledConnect the power cord Assembling the Vpap Adapt SV SystemAttach the mask to the air tubing Connecting a Humidifier HumidifiersHumidAire HumidAire 2i attached to the Vpap Adapt SVHumidAire Page ResLink Anti-bacterial FilterUsing DC Power to Run the Vpap Adapt SV Supplemental OxygenUsing the Vpap Adapt SV Standby ModeStarting Treatment Stopping TreatmentControl Panel Functions LCD screenStart/Stop key Up/Down keyAdjusting Settings Alarm LEDs and Alarm MuteLeft key green Right key redYou wish to change the setting for the mask you are using ExampleNavigating the Patient menu Using the Vpap Adapt SV MenusSettings Menu MaskLearn Circuit Ramp Cpap mode only Results MenuSmartStop Leak AlertOptions Menu Treatment Screens Servicing MenuPage Alarms Low Mask Pressure AlarmIf a low pressure alarm sounds Triggered byPower Fail Alarm High Pressure AlarmHigh Leak Alarm Insufficient Pressure Support Alarm Flow Blocked AlarmIf an insufficient pressure support alarm sounds If a flow blocked alarm soundsPage Cleaning and Maintenance DailyWeekly Air tubing assembly removed for cleaning PeriodicallyAir Filter ServicingHypoallergenic Air Filter Fitting the filterPage Troubleshooting Unusual mannerPage Alarms GlossaryPage Technical Specifications Inspiratory Trigger Characteristics IEC 601-1 classificationsPage Mask setting flow/pressure characteristics Glossary of symbolsEmissions test Compliance Next Portable and mobile RF communications Separation distance according to frequency of transmitter Limited Warranty Page Index