ResMed Adapt SV System manual Results Menu, SmartStop, Leak Alert, Ramp Cpap mode only

Page 29

7.When the function is complete, a screen will appear saying that the circuit has been learned successfully. The next menu item is then displayed. Commence treatment as described in “Starting Treatment” on page 17.

If there is a problem with the circuit a screen saying ’Invalid circuit’ will be displayed instead of the progress screen. Check that all the connections between the pieces of equipment are secure. You may need to return to the previous chapter of this manual to check that you have set up the system correctly.

SmartStop

Turn the SmartStop function on or off. When SmartStop is on, the

VPAP Adapt SV will automatically turn itself off when the mask is removed.

Note: The unit will automatically ’SmartStart’ whenever you start to breathe into the mask.

Leak Alert

Turn Leak Alert on or off. Leak Alert sounds an alarm when you have a high leak from your mask. You can then adjust the mask on your face to remove the leak. If Leak Alert is turned off, an extra leak alert message will be displayed at the end of a session if high leak occurred. The message will be displayed until a key is pressed.

Ramp (CPAP mode only)

Ramp time is the length of time taken for the air pressure to build up to the maximum pressure set by your clinician. This setting allows you to increase or decrease the ramp time in 5-minute intervals.

If you find that you are still awake when the air pressure starts to build you may wish to increase the Ramp time.

Results Menu

This menu has a series of screens showing information about your most recent treatment session. If enabled by your clinician the following data may be viewed:

Mask-fit

Average Pressure

Usage.

Using the VPAP Adapt SV

23

Image 29
Contents Vpap Adapt SV USA ENG Reorder number 26869/2 06 Page Contents Daily Weekly Periodically Air Filter Vpap Adapt SV IntroductionUser/Owner Responsibility DefinitionsPage Page Page Quick Setup Guide Page Vpap Adapt SV Components Vpap Adapt SV SystemAir tubing fully assembled MasksAssembling the Vpap Adapt SV System Connect the power cordAttach the mask to the air tubing Humidifiers Connecting a HumidifierHumidAire 2i attached to the Vpap Adapt SV HumidAireHumidAire Page Anti-bacterial Filter ResLinkSupplemental Oxygen Using DC Power to Run the Vpap Adapt SVStandby Mode Using the Vpap Adapt SVStarting Treatment Stopping TreatmentLCD screen Control Panel FunctionsStart/Stop key Up/Down keyAlarm LEDs and Alarm Mute Adjusting SettingsLeft key green Right key redExample You wish to change the setting for the mask you are usingMenus Navigating the Patient menu Using the Vpap Adapt SVLearn Circuit Settings MenuMask Results Menu Ramp Cpap mode onlySmartStop Leak AlertOptions Menu Servicing Menu Treatment ScreensPage Low Mask Pressure Alarm AlarmsIf a low pressure alarm sounds Triggered byHigh Leak Alarm Power Fail AlarmHigh Pressure Alarm Flow Blocked Alarm Insufficient Pressure Support AlarmIf an insufficient pressure support alarm sounds If a flow blocked alarm soundsPage Weekly Cleaning and MaintenanceDaily Periodically Air tubing assembly removed for cleaningServicing Air FilterHypoallergenic Air Filter Fitting the filterPage Unusual manner TroubleshootingPage Glossary AlarmsPage Technical Specifications IEC 601-1 classifications Inspiratory Trigger CharacteristicsPage Glossary of symbols Mask setting flow/pressure characteristicsEmissions test Compliance Next Portable and mobile RF communications Separation distance according to frequency of transmitter Limited Warranty Page Index