ResMed Adapt SV System manual Options Menu

Page 30

Mask-fit

Gives a rating of how well the mask was fitting during your last session on the VPAP Adapt SV. The stars indicate how good the fit was (more stars = better fit).

Star rating

Definition

 

 

*****

Excellent

 

 

****-

Very good

 

 

***--

Good

 

 

**---

Adjust mask

 

 

*----

Adjust mask

 

 

HIGH LEAK

Adjust mask

 

 

Average Pressure

Provides information on the average air pressure during your most recent session on the VPAP Adapt SV.

Usage

Tells you how long the VPAP Adapt SV was in use during your most recent session.

Options Menu

The Options menu allows you to change:

Smart Data (Auto Appear)

Backlight

Language.

Smart Data

If the SMART DATA - AUTO APPEAR option is set to ON, the screens available under the Results menu will be displayed automatically for approximately 20 minutes after your session is completed. After this time the data will still be available in the Results menu.

If you want to turn off AUTO APPEAR, select ’enter’ in the SMART DATA screen by pressing the Left key. The AUTO APPEAR screen will be displayed. Select ’change’ by pressing the Left key and you will switch from ON to OFF (similarly, you can turn it from OFF to ON). Your clinician may also turn off AUTO APPEAR.

Backlight

On: Display a permanent backlight for the LCD.

Auto: Backlight turns off if no button has been pressed for two minutes.

Language

Change the language of the LCD display. Languages available are: English, French, German, Italian, Spanish, Portuguese, Swedish, Dutch.

24

Image 30
Contents Vpap Adapt SV USA ENG Reorder number 26869/2 06 Page Contents Daily Weekly Periodically Air Filter User/Owner Responsibility IntroductionVpap Adapt SV DefinitionsPage Page Page Quick Setup Guide Page Vpap Adapt SV System Vpap Adapt SV ComponentsMasks Air tubing fully assembledConnect the power cord Assembling the Vpap Adapt SV SystemAttach the mask to the air tubing Connecting a Humidifier HumidifiersHumidAire HumidAire 2i attached to the Vpap Adapt SVHumidAire Page ResLink Anti-bacterial FilterUsing DC Power to Run the Vpap Adapt SV Supplemental OxygenStarting Treatment Using the Vpap Adapt SVStandby Mode Stopping TreatmentStart/Stop key Control Panel FunctionsLCD screen Up/Down keyLeft key green Adjusting SettingsAlarm LEDs and Alarm Mute Right key redYou wish to change the setting for the mask you are using Example Navigating the Patient menu Using the Vpap Adapt SV MenusSettings Menu MaskLearn Circuit SmartStop Ramp Cpap mode onlyResults Menu Leak AlertOptions Menu Treatment Screens Servicing MenuPage If a low pressure alarm sounds AlarmsLow Mask Pressure Alarm Triggered byPower Fail Alarm High Pressure AlarmHigh Leak Alarm If an insufficient pressure support alarm sounds Insufficient Pressure Support AlarmFlow Blocked Alarm If a flow blocked alarm soundsPage Cleaning and Maintenance DailyWeekly Air tubing assembly removed for cleaning PeriodicallyHypoallergenic Air Filter Air FilterServicing Fitting the filterPage Troubleshooting Unusual mannerPage Alarms GlossaryPage Technical Specifications Inspiratory Trigger Characteristics IEC 601-1 classificationsPage Mask setting flow/pressure characteristics Glossary of symbolsEmissions test Compliance Next Portable and mobile RF communications Separation distance according to frequency of transmitter Limited Warranty Page Index