SECTION
| DO NOT USE |
POSITIVE (+) | NEGATIVE |
Terminal/Post | Terminal/Post |
POSITIVE (+)
Terminal/Post
NEGATIVE
Terminal/Post
U1 Batteries
POSITIVE (+) Terminal/Post | NEGATIVE | DO NOT USE | |
Terminal/Post and Clamp | |||
(Note position of clamp) |
| ||
|
|
NEGATIVE
Terminal/Post and Clamp
Group 22NF Batteries | POSITIVE (+) Terminal/Post |
| |
| (Note position of clamp) |
FIGURE 11.6 Connecting Battery Cables
Perform one (1) of the following methods for connecting the battery cable(s):
•Dual U1 Batteries - Use direct mount method described on page 54. Refer to FIGURE 11.7.
•Dual Group 22NF Batteries with Mounting Holes in the Terminal(s)/Post(s) - Use direct mount method described on page 54. Refer to FIGURE 11.7.
•Dual Group 22NF Batteries without Mounting Holes in the Terminal(s)/Post(s) - Use battery clamp method described on page 57. Refer to FIGURE 11.8 and FIGURE 11.9.
Direct Mount Method
NOTE: For this procedure, refer to FIGURE 11.7.
1.Install battery terminal cap(s) onto battery cable(s):
A.Dual U1 Batteries
i.ORANGE battery terminal cap onto RED battery cable.
ii.GREY battery terminal cap onto BLACK battery cable.
B.Dual Group 22NF BATTERIES
i.RED battery terminal cap onto RED battery cable.
ii.BLACK battery terminal cap onto BLACK battery cable.
P9000™ XDT | 54 | Part No. 1118386 |