Wet Leg Condition

Condensation of the gas above the liquid slowly causes the low side of the transmitter piping to fill with liquid. The pipe is purposely filled with a convenient reference fluid to eliminate this potential error. This is a wet leg condition.

The reference fluid will exert a head pressure on the low side of the transmitter. Zero elevation of the range must then be made. See Figure 2-20

Figure 2-20. Wet Leg Example.

X

Y

Z

LT

H L

Let X equal the vertical distance between the minimum and maximum measurable levels (500 in.).

Let Y equal the vertical distance between the transmitter datum line and the minimum measurable level (50 in.).

Let z equal the vertical distance between the top of the liquid in the wet leg and the transmitter datum line (600 in.).

Let SG1 equal the specific gravity of the fluid (1.0).

Let SG2 equal the specific gravity of the fluid in the wet leg (1.1).

Let h equal the maximum head pressure to be measured in inches of water. Let e equal the head pressure produced by Y expressed in inches of water. Let s equal head pressure produced by z expressed in inches of water.

Let Range equal e – s to h + e – s. Then h = (X)(SG1)

=500 x 1.0

=500 in H2O

e = (Y)(SG1)

=50 x 1.0

=50 inH2O

s= (z)(SG2)

=600 x 1.1

=660 inH20

Range = e – s to h + e – s.

=50 – 660 to 500 + 50 – 660

=–610 to –110 inH20

ZERO ELEVATION Manual background 20

mA dc

4

-610

-110

0

inH2O

2-32

Image 42
Contents with FOUNDATION Fieldbus Protocol Reference ManualRosemount 2051 Pressure Transmitter Page Rosemount Rosemount 2051 PressureTransmitter with FOUNDATION Fieldbus Reference ManualPage SECTION 3 Configuration Table of ContentsSECTION 1 Introduction SECTION 2 Installation RosemountAPPENDIX A Reference Data SECTION Operation and MaintenanceSECTION 5 Troubleshooting RosemountRosemount APPENDIX B Approval InformationAPPENDIX C Block Information Reference ManualRosemount Reference ManualTOC-4 Introduction USING THIS MANUAL SERVICE SUPPORTSection RosemountMODELS COVERED RosemountReference Manual Section InstallationOVERVIEW SAFETY MESSAGES Warnings RosemountMECHANICAL GENERALCONSIDERATIONS ENVIRONMENTAL2051C Coplanar Flange Dimensional Drawing INSTALLATION PROCEDURESDimensional Drawings RosemountReference Manual Coplanar Flange Mounting Configurations withRosemount 00809-0200-4101,Rev AA2051C Coplanar with Traditional Flange RosemountReference Manual Rosemount Traditional Flange Mounting Configurations withOptional Brackets for 2-in.Pipe or Panel Mounting Reference ManualRosemount 2051T Dimensional Drawings2051T with Rosemount 306 Integral Manifold Reference ManualPipe Mounting RosemountReference Manual Panel Mounting2051L Liquid Level RosemountReference Manual Mount the Transmitter RosemountReference Manual Rosemount Reference Manual00809-0200-4101,Rev AA July Rosemount Reference Manual00809-0200-4101,Rev AA July Rosemount Reference Manual00809-0200-4101,Rev AA July Reference Manual Figure 2-6.Traditional Flange Bolt ConfigurationsRosemount 00809-0200-4101,Rev AA JulyImpulse Piping RosemountReference Manual Rosemount Reference ManualFlow Process Connections RosemountReference Manual Rosemount Reference Manual00809-0200-4101,Rev AA July Housing Rotation RosemountReference Manual Rosemount LCD DisplayTagging Reference ManualRosemount Conduit InstallationELECTRICAL Reference ManualWiring RosemountReference Manual Transient Protection Terminal Block RosemountReference Manual JumpersSecurity RosemountReference Manual Grounding RosemountReference Manual Rosemount Figure 2-17.External Ground AssemblyExternal Ground Assembly Reference ManualRosemount HAZARDOUS LOCATIONS CERTIFICATIONSROSEMOUNT 305, 306 AND 304 MANIFOLDS Reference ManualManifold Installation Procedure Rosemount Rosemount 305 Integral Manifold InstallationProcedure Rosemount 306 Integral Conventional Manifold Installation ProcedureIntegral Manifold Operation RosemountReference Manual Rosemount Reference Manual00809-0200-4101,Rev AA July Rosemount LIQUID LEVEL MEASUREMENTOpen Vessels Closed Vessels Reference ManualRosemount Reference Manual00809-0200-4101,Rev AA July Rosemount Reference Manual00809-0200-4101,Rev AA July Rosemount Reference ManualSection ConfigurationOVERVIEW SAFETY MESSAGES Warnings RosemountGENERAL BLOCK INFORMATION Modes DEVICE CAPABILITIES Link Active SchedulerCapabilities RosemountRosemount RESOURCE BLOCK FEATURES and FEATURES SELSimulation Reference ManualMAX_NOTIFY RosemountReference Manual Rosemount Configure the AI blockANALOG INPUT AI FUNCTION BLOCK Reference ManualConfiguration Examples RosemountReference Manual Rosemount Reference Manual00809-0200-4101,Rev AA July Rosemount Reference Manual00809-0200-4101,Rev AA July Rosemount FilteringLow Cutoff Reference ManualRosemount Process Alarms Alarm PriorityStatus Options Reference ManualAdvanced Features LCD BLOCK RosemountReference Manual Rosemount Reference Manual00809-0200-4101,Rev AA July Rosemount Section 4 Operation and MaintenanceOVERVIEW SAFETY MESSAGES Warnings Reference ManualSTATUS Master Reset Method Simulation RosemountReference Manual Rosemount CALIBRATION Sensor CalibrationUpper and Lower Trim Methods Reference ManualRosemount Sensor Calibration, Zero Trim MethodFactory Calibration Method Reference ManualRosemount Section 5 TroubleshootingOVERVIEW SAFETY MESSAGES Warnings Reference ManualReference Manual TROUBLESHOOTING GUIDESRosemount 00809-0200-4101,Rev AA JulyReference Manual Figure 5-2.Problems with communications flowchartRosemount 00809-0200-4101,Rev AA JulyReference Manual Table 5-1.Troubleshooting guideRosemount 00809-0200-4101,Rev AA JulyRESOURCE BLOCK RosemountReference Manual SENSOR TRANSDUCER BLOCK RosemountReference Manual Reference Manual LCD TRANSDUCER BLOCKRosemount ANALOG INPUT AI FUNCTION BLOCKReference Manual 1.Put Resource block into OOS Out of ServiceRosemount 00809-0200-4101,Rev AA JulyRosemount DISASSEMBLY PROCEDURES Remove from ServiceRemove Terminal Block Reference ManualRemove the Electronics Board RosemountReference Manual Reassemble the 2051C Process Flange REASSEMBLY PROCEDURES Attach theElectronics Board Install the Terminal Block RosemountInstall the Drain/Vent Valve RosemountReference Manual Appendix A PERFORMANCE SPECIFICATIONSConformance To Specification ±3σ Sigma Reference DataLine Pressure Effect per 1000 psi 6,9 MPa Long Term StabilityDynamic Performance RosemountMounting Position Effects Vibration Effect Power Supply EffectAmbient Temperature Effect per 50F 28C Electromagnetic Compatibility EMCProtocols FUNCTIONAL SPECIFICATIONS Range and Sensor LimitsService RosemountRosemount Reference Manual00809-0200-4101,Rev AA July Overpressure Limits RosemountReference Manual Rosemount Static Pressure Limit Burst Pressure LimitsTemperature Limits Reference ManualRosemount Humidity Limits Volumetric Displacement DampingFailure Mode Alarm Reference Manual2051T Process Wetted Parts PHYSICAL SPECIFICATIONS Electrical ConnectionsProcess Connections 2051C Process Wetted Parts 2051L Process Wetted PartsNon-WettedParts for 2051C/T/L RosemountReference Manual Table A-5.2051L Weights without Options Shipping WeightsTable A-4.Transmitter Weights without Options Table A-6.Transmitter Options WeightsORDERING INFORMATION RosemountReference Manual Rosemount Reference ManualAlternate Process Connection: Flange2 Rosemount Reference ManualCSA FISCO Intrinsically Safe Rosemount Reference ManualA-15 Rosemount Reference ManualGGage AAbsolute Rosemount Reference ManualFM Intrinsically Safe, Division Special Certifications Q4 Calibration Certificate RosemountReference Manual Prior-usecertificate of FMEDA dataRosemount Reference Manual4 -300to 300 psi/3 psi -20,7to 20,7 bar/0,2 bar Rosemount Reference ManualSyltherm XLT ATEX Flameproof, Intrinsic Safety, Type n, Dust RosemountReference Manual OPTIONS RosemountReference Manual Rosemount Reference Manual00809-0200-4101,Rev AA July Rosemount Reference Manual00809-0200-4101,Rev AA July Reference Manual SPARE PARTSRosemount LCD Display, FOUNDATION fieldbusRosemount Reference ManualNickel-platedcarbon steel Rosemount Reference ManualGage Flange and Adapter Bolt Kit Set of Rosemount Reference ManualA-28 Warnings OVERVIEW SAFETY MESSAGESAppendix B Approval Information Approved Manufacturing LocationsHazardous Locations Certifications European Directive InformationFIELDBUS PROTOCOL RosemountRosemount Reference Manual00809-0200-4101,Rev AA July Rosemount Reference Manual00809-0200-4101,Rev AA July Rosemount Reference Manual00809-0200-4101,Rev AA July Rosemount Reference Manual00809-0200-4101,Rev AA July Rosemount Reference Manual00809-0200-4101,Rev AA July APPROVAL DRAWINGS Factory Mutual FM RosemountReference Manual Rosemount Reference ManualRosemount Reference ManualB-10 Rosemount Reference ManualB-11 Rosemount Reference ManualB-12 Rosemount Reference ManualB-13 Rosemount Reference ManualB-14 Rosemount Reference ManualB-15 Rosemount Reference ManualB-16 Rosemount Reference ManualB-17 Rosemount Reference ManualB-18 Rosemount Reference ManualB-19 Rosemount Reference ManualB-20 Reference Manual Canadian Standards Association CSARosemount B-21Rosemount Reference ManualB-22 Rosemount Reference ManualB-23 Rosemount Reference ManualB-24 Rosemount Reference ManualB-25 Rosemount Reference ManualB-26 Rosemount Reference ManualB-27 Rosemount Reference ManualB-28 Rosemount Reference ManualB-29 Rosemount Reference ManualB-30 TRANSDUCER BLOCK Overview Appendix CBlock Information RosemountParameters and Descriptions RosemountReference Manual Rosemount Reference ManualPRIMARY_VALUE_RANGE Rosemount Reference Manual00809-0200-4101,Rev AA July Rosemount Reference Manual00809-0200-4101,Rev AA July Rosemount TroubleshootingOverview Reference ManualParameters and Descriptions RosemountReference Manual 00809-0200-4101,Rev AA JulyRosemount Reference ManualFLANGE_MTL Rosemount Reference ManualREM_SEAL_FILL Rosemount Reference ManualSimulate_STATE Reference Manual Block ErrorsRosemount 00809-0200-4101,Rev AA JulyRosemount Reference Manual00809-0200-4101,Rev AA July Rosemount Reference ManualMode will not leave Rosemount Reference ManualC-14 Index RosemountReference Manual Rosemount Reference Manual00809-0200-4101,Rev AA July Rosemount Reference Manual00809-0200-4101,Rev AA July Rosemount Reference ManualIndex-4 Rosemount Reference Manual00809-0200-4101,Rev AA July NOTES Rosemount Reference ManualPage Rosemount ¢00809-0100-4801V¤Reference Manual