Philips M5066A owner manual Accessories for the HeartStart, REF 68-PCHAT

Page 31

Philips Medical Systems

A

A Accessories for the HeartStart

Accessories* for the HeartStart Defibrillator available separately from your Philips representative or on-line at www.medical.philips.com/heartstart include:

Battery (spare recommended) [REF: M5070A]

Pads

Adult SMART Pads Cartridge (spare recommended) [REF: M5071A]

Infant/Child SMART Pads Cartridge [REF: M5072A]

Carry Cases

Standard carry case, with paramedic’s scissors and room for spare pad cartridge and battery [REF: M5075A]

Slim carry case, with paramedic’s scissors [REF: M5076A]

Plastic waterproof hardshell carry case [REF: YC]

Fast Response Kit (pouch containing a pocket mask, a disposable razor, 2 pairs of gloves, a pair of paramedic’s scissors, and an absorbent wipe)

[REF: 68-PCHAT]

Data Management Software

HeartStart Configure PDA software [REF: 989803143041]

HeartStart CaseCapture PDA software [REF: 989803143051]

HeartStart Review Express Connect [REF: 861311 option A01]

HeartStart Event Review, single PC license [REF: M3834A]

HeartStart Event Review, organization-wide license [REF: 989803141811]

HeartStart Event Review Pro, single PC license [REF: 861276 option A01]

HeartStart Event Review Pro, three-PC license [REF: 861276 option A02]

HeartStart Event Review Pro, organization-wide license [REF: 861276 option A03]

Infrared cable for use with HeartStart Event Review software [REF: ACT-IR]

HeartStart Defibrillator Quick Reference [REF: M5066-97800]

* Certain accessories require a prescription in the United States.

A-1

Image 31
Contents Edition M5066AIntentionally blank Information Button. This HeartStart Defibrillator M5066APads Cartridge Handle On/Off Button. Press thisIntentionally blank Quick Reference Intentionally blank Important Note HeartStartIntentionally blank Authorized EU representative About this editionEdition history CopyrightIntentionally blank Contents Appendices Indications for Use Introduction to the HeartStartDescription Sudden Cardiac ArrestNational and local requirements Training and practiceFor more information Package contents Setting up the HeartStartHeartstart M5066A Pads Cartridge, place it in the storage area in the case Recommended accessories Overview Using the HeartStartPull the green handle Place the pads If a shock is needed Press the Shock buttonRemove the Infant/Child Pads Cartridge from its package Treating infants and childrenDo not Delay Treatment When emergency medical services arrivePhilips Medical Systems Heartstart M5066A After each use After using the HeartStartHeartStart data storage Heartstart M5066A Maintaining the HeartStart Routine MaintenancePeriodic checks Troubleshooting tips Cleaning the HeartStartDisposing of the HeartStart REF 68-PCHAT Accessories for the HeartStartHeartstart M5066A ECG Glossary of termsAED CPRNSA Smart NSA pause SCA Symbol Description Glossary of symbols/controlsDefibrillator and opens pads cartridge for use Lithium manganese dioxide battery Cartridge contents one set of two defibrillation pads Symbol Description Patient handling Metal objects such as a bed frame or stretcher PrecautionsContact with the patient Regularly for damage, according to directionsEnvironmental HeartStart Defibrillator specificationsTechnical information PhysicalCategory Sealing Controls and indicatorsCurrent a Energy J Defibrillation WaveformCategory Waveform parameters DeliveredShock-to-shock cycle time Disarm AED modeNewborn 14 J/kg Category Function Shockable rhythms Non-shockable rhythms ECG analysis systemAnalysis protocol ECG analysis performance Prior to insertion Standby life Accessories specificationsBattery M5070A Category Specifications Battery typeWhole and may also endanger human health Environmental considerationsRegulations ECG out data ConfigurationParameter Speaker volume Device optionsPatient treatment protocol options Monitoring during NSA pause type SettingsStandard NSA During a Smart NSA pause, Pause HeartStartCPR4 Yes, No InstalledInfants and children when an infant Child pads cartridge is installedHeartstart M5066A Testing Testing and troubleshootingTroubleshooting Green Ready light is solid HeartStart tells you Troubleshooting while the HeartStart is in useTo insert a pads cartridge HeartStart tells you To stop all motion Contact Philips for service if needed Troubleshooting while the HeartStart is not in useGreen Ready light is not on Behavior Cispr Electromagnetic conformityElectromagnetic emissions Emissions testElectromagnetic immunity Separation distance according to frequency of transmitter m Environmental considerations Important warnings and remindersIntentionally blank Intentionally blank Intentionally blank Intentionally blank Intentionally blank REF M5066-91901