Philips M5066A Electromagnetic conformity, Electromagnetic emissions, Emissions test, Cispr

Page 61

HAdditional technical information required for European conformity

Electromagnetic conformity

Guidance and manufacturer’s declaration: The HeartStart is intended for use in the

electromagnetic environment specified in the tables below. The customer or user

of the HeartStart should assure that it is used in such an environment.

Electromagnetic emissions

Philips Medical Systems

emissions test

RF

CISPR 11

compliance

electromagnetic environment – guidance

Group 1 The HeartStart uses RF energy only for its internal function.

Class B Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.

The HeartStart is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.

H

H-1

Image 61
Contents Edition M5066AIntentionally blank Pads Cartridge Handle HeartStart Defibrillator M5066AOn/Off Button. Press this Information Button. ThisIntentionally blank Quick Reference Intentionally blank Important Note HeartStartIntentionally blank Edition history About this editionCopyright Authorized EU representativeIntentionally blank Contents Appendices Description Introduction to the HeartStartSudden Cardiac Arrest Indications for UseNational and local requirements Training and practiceFor more information Package contents Setting up the HeartStartHeartstart M5066A Pads Cartridge, place it in the storage area in the case Recommended accessories Overview Using the HeartStartPull the green handle Place the pads If a shock is needed Press the Shock buttonRemove the Infant/Child Pads Cartridge from its package Treating infants and childrenDo not Delay Treatment When emergency medical services arrivePhilips Medical Systems Heartstart M5066A After each use After using the HeartStartHeartStart data storage Heartstart M5066A Maintaining the HeartStart Routine MaintenancePeriodic checks Troubleshooting tips Cleaning the HeartStartDisposing of the HeartStart REF 68-PCHAT Accessories for the HeartStartHeartstart M5066A AED Glossary of termsCPR ECGNSA Smart NSA pause SCA Symbol Description Glossary of symbols/controlsDefibrillator and opens pads cartridge for use Lithium manganese dioxide battery Cartridge contents one set of two defibrillation pads Symbol Description Patient handling Contact with the patient PrecautionsRegularly for damage, according to directions Metal objects such as a bed frame or stretcherTechnical information HeartStart Defibrillator specificationsPhysical EnvironmentalCategory Sealing Controls and indicatorsCategory Waveform parameters Defibrillation WaveformDelivered Current a Energy JShock-to-shock cycle time Disarm AED modeNewborn 14 J/kg Category Function Shockable rhythms Non-shockable rhythms ECG analysis systemAnalysis protocol ECG analysis performance Battery M5070A Accessories specificationsCategory Specifications Battery type Prior to insertion Standby lifeWhole and may also endanger human health Environmental considerationsRegulations Parameter Speaker volume ConfigurationDevice options ECG out dataPatient treatment protocol options Standard NSA NSA pause type SettingsDuring a Smart NSA pause, Pause HeartStart Monitoring duringCPR4 Infants and children when an infant InstalledChild pads cartridge is installed Yes, NoHeartstart M5066A Testing Testing and troubleshootingTroubleshooting Green Ready light is solid HeartStart tells you Troubleshooting while the HeartStart is in useTo insert a pads cartridge HeartStart tells you To stop all motion Contact Philips for service if needed Troubleshooting while the HeartStart is not in useGreen Ready light is not on Behavior Electromagnetic emissions Electromagnetic conformityEmissions test CisprElectromagnetic immunity Separation distance according to frequency of transmitter m Environmental considerations Important warnings and remindersIntentionally blank Intentionally blank Intentionally blank Intentionally blank Intentionally blank REF M5066-91901
Related manuals
Manual 68 pages 2.08 Kb

M5066A specifications

The Philips M5066A is a state-of-the-art multi-parameter patient monitor designed to enhance healthcare delivery in various clinical settings. This versatile monitoring solution is widely utilized in hospitals, especially in critical care units and during transport, owing to its robust features and reliable performance.

One of the main features of the M5066A is its ability to monitor multiple vital signs simultaneously, including ECG, heart rate, invasive and non-invasive blood pressure, respiration rate, temperature, and saturation levels. This multi-parameter capability allows healthcare professionals to gain a comprehensive view of a patient’s health status, enabling timely interventions and improved patient outcomes.

The M5066A incorporates advanced technologies such as Philips’ proprietary IntelliVue technology, which enhances the accuracy and reliability of vital sign measurements. The monitor uses sophisticated algorithms to filter out noise and interferences, ensuring that the data presented to caregivers is both precise and actionable. The device also supports a range of connectivity options, allowing for seamless integration with hospital information systems and electronic medical records (EMRs). This connectivity facilitates the easy transfer and management of patient data, promoting better coordination of care.

Another significant characteristic of the M5066A is its user-friendly interface. The large, high-resolution display provides clear visuals of vital sign trends and parameters, enabling quick assessments by healthcare professionals. Customizable alarms and alerts can be programmed to suit specific patient needs, ensuring that caregivers are notified of critical changes in a timely manner.

The M5066A is also designed with patient comfort and safety in mind. The device's compact and lightweight design facilitates easy transport, while its durable construction ensures reliability in demanding environments. Furthermore, the monitor's battery backup allows for continuous monitoring even during power outages or when moving patients between departments.

In conclusion, the Philips M5066A multi-parameter patient monitor is a sophisticated tool that enhances patient monitoring by providing accurate, real-time data. Its advanced technologies, comprehensive monitoring capabilities, user-friendly interface, and focus on safety and comfort make it an invaluable asset in any clinical setting, helping healthcare providers deliver the highest standard of care.