Philips M5066A owner manual Nsa

Page 34

B-2

 

 

fibrillation

A disturbance of the normal heart rhythm that results in chaotic, disorganized

 

activity that cannot effectively pump blood. Ventricular fibrillation (fibrillation in

 

the lower chambers of the heart) is associated with sudden cardiac arrest.

HeartStart Event Review

A suite of data management software applications for use by trained personnel to

 

review and analyze HeartStart Defibrillator patient use and by authorized

 

personnel to alter HeartStart configuration. Information is available from Philips

 

Medical Systems on the internet at http://www.medical.philips.com/goto/

 

eventreview.

i-button

A blue “information” button on the front of the HeartStart Defibrillator. If the

 

i-button is pressed during the 30 seconds it flashes during a patient care pause, the

 

HeartStart provides CPR Coaching;* if the i-button is pressed when it is flashing

 

and the HeartStart is chirping, the HeartStart provides troubleshooting guidance.

 

At other times, if the i-button is pressed and held until it beeps once, the

 

HeartStart provides summary information about its last clinical use and device

 

status. When the i-button is on solid (not flashing), it indicates the user may safely

 

touch the patient.

infrared

A method of sending information using a special part of the light spectrum. It is

communications

used to transmit information between the HeartStart Defibrillator and a computer

 

running HeartStart Event Review software.

NSA

“No Shock Advised,” a decision made by the HeartStart Defibrillator that a shock

 

is not needed, based on analysis of the patient’s heart rhythm.

NSA pause

A pause provided by the HeartStart Defibrillator following an NSA decision. The

 

pause can be configured to a “standard” NSA pause or a “SMART” NSA pause.

 

During a standard NSA pause the defibrillator performs no background

 

monitoring of patient rhythm. During a SMART NSA pause, the defibrillator

 

conducts background monitoring and, if it detects an artifact-free shockable

 

rhythm, will exit the pause and begin rhythm analysis. If the HeartStart detects

 

artifact such as that created by CPR, or if the user presses the i-button for CPR

 

Coaching during a SMART NSA pause, the defibrillator will not exit the pause for

 

rhythm analysis in order to allow CPR to be completed uninterrupted.

non-shockable rhythm

A heart rhythm that the HeartStart Defibrillator determines is not appropriate for

 

defibrillation.

On/Off button

A green button located on the front of the HeartStart Defibrillator. Pressing the

 

On/Off button when the defibrillator is in standby mode turns the defibrillator on;

 

pressing and holding the On/Off button for one second when the defibrillator is on

 

turns the defibrillator off and disarms the defibrillator. In addition, pressing the

 

 

 

 

* Pressing the i-button for CPR Coaching during a SMART NSA pause turns off

 

background monitoring.

HEARTSTART M5066A

 

 

Philips Medical Systems

Image 34
Contents M5066A EditionIntentionally blank On/Off Button. Press this HeartStart Defibrillator M5066APads Cartridge Handle Information Button. ThisIntentionally blank Quick Reference Intentionally blank HeartStart Important NoteIntentionally blank Copyright About this editionEdition history Authorized EU representativeIntentionally blank Contents Appendices Sudden Cardiac Arrest Introduction to the HeartStartDescription Indications for UseNational and local requirements Training and practiceFor more information Setting up the HeartStart Package contentsHeartstart M5066A Pads Cartridge, place it in the storage area in the case Recommended accessories Using the HeartStart OverviewPull the green handle Place the pads Press the Shock button If a shock is neededTreating infants and children Remove the Infant/Child Pads Cartridge from its packageWhen emergency medical services arrive Do not Delay TreatmentPhilips Medical Systems Heartstart M5066A After each use After using the HeartStartHeartStart data storage Heartstart M5066A Maintaining the HeartStart Routine MaintenancePeriodic checks Troubleshooting tips Cleaning the HeartStartDisposing of the HeartStart Accessories for the HeartStart REF 68-PCHATHeartstart M5066A CPR Glossary of termsAED ECGNSA Smart NSA pause SCA Symbol Description Glossary of symbols/controlsDefibrillator and opens pads cartridge for use Lithium manganese dioxide battery Cartridge contents one set of two defibrillation pads Symbol Description Patient handling Regularly for damage, according to directions PrecautionsContact with the patient Metal objects such as a bed frame or stretcherPhysical HeartStart Defibrillator specificationsTechnical information EnvironmentalControls and indicators Category SealingDelivered Defibrillation WaveformCategory Waveform parameters Current a Energy JShock-to-shock cycle time Disarm AED modeNewborn 14 J/kg Category Function Shockable rhythms Non-shockable rhythms ECG analysis systemAnalysis protocol ECG analysis performance Category Specifications Battery type Accessories specificationsBattery M5070A Prior to insertion Standby lifeWhole and may also endanger human health Environmental considerationsRegulations Device options ConfigurationParameter Speaker volume ECG out dataPatient treatment protocol options During a Smart NSA pause, Pause HeartStart NSA pause type SettingsStandard NSA Monitoring duringCPR4 Child pads cartridge is installed InstalledInfants and children when an infant Yes, NoHeartstart M5066A Testing Testing and troubleshootingTroubleshooting Green Ready light is solid HeartStart tells you Troubleshooting while the HeartStart is in useTo insert a pads cartridge HeartStart tells you To stop all motion Contact Philips for service if needed Troubleshooting while the HeartStart is not in useGreen Ready light is not on Behavior Emissions test Electromagnetic conformityElectromagnetic emissions CisprElectromagnetic immunity Separation distance according to frequency of transmitter m Important warnings and reminders Environmental considerationsIntentionally blank Intentionally blank Intentionally blank Intentionally blank Intentionally blank REF M5066-91901
Related manuals
Manual 68 pages 2.08 Kb

M5066A specifications

The Philips M5066A is a state-of-the-art multi-parameter patient monitor designed to enhance healthcare delivery in various clinical settings. This versatile monitoring solution is widely utilized in hospitals, especially in critical care units and during transport, owing to its robust features and reliable performance.

One of the main features of the M5066A is its ability to monitor multiple vital signs simultaneously, including ECG, heart rate, invasive and non-invasive blood pressure, respiration rate, temperature, and saturation levels. This multi-parameter capability allows healthcare professionals to gain a comprehensive view of a patient’s health status, enabling timely interventions and improved patient outcomes.

The M5066A incorporates advanced technologies such as Philips’ proprietary IntelliVue technology, which enhances the accuracy and reliability of vital sign measurements. The monitor uses sophisticated algorithms to filter out noise and interferences, ensuring that the data presented to caregivers is both precise and actionable. The device also supports a range of connectivity options, allowing for seamless integration with hospital information systems and electronic medical records (EMRs). This connectivity facilitates the easy transfer and management of patient data, promoting better coordination of care.

Another significant characteristic of the M5066A is its user-friendly interface. The large, high-resolution display provides clear visuals of vital sign trends and parameters, enabling quick assessments by healthcare professionals. Customizable alarms and alerts can be programmed to suit specific patient needs, ensuring that caregivers are notified of critical changes in a timely manner.

The M5066A is also designed with patient comfort and safety in mind. The device's compact and lightweight design facilitates easy transport, while its durable construction ensures reliability in demanding environments. Furthermore, the monitor's battery backup allows for continuous monitoring even during power outages or when moving patients between departments.

In conclusion, the Philips M5066A multi-parameter patient monitor is a sophisticated tool that enhances patient monitoring by providing accurate, real-time data. Its advanced technologies, comprehensive monitoring capabilities, user-friendly interface, and focus on safety and comfort make it an invaluable asset in any clinical setting, helping healthcare providers deliver the highest standard of care.