C. Crane A-66 manual Set functions listed in -5 a through h

Page 40

Section 12

Optipay™CC

PALM PILOT® USAGE

a

 

b

 

c

 

d

 

e

 

f

 

g

 

h

 

j

i

Figure 12-5Operating Modes

4.Set functions listed in Figure 12-5 “a” through “h”.

Select the desired settings and click Send (See Figure 12-5 i) to program the Coin Changer or Cancel (See Figure 12-5 j) to return to the Settings screen.

a). Inventory check box functions are:

Blocked Inventory keypad is disabled

Enabled by machine control

Inventory keypad can be enabled by the Vending Machine. This requires a service pass code

Enabled Inventory keypad enabled

b). Payout security stock allowed Check to enable the machine to pay the entire contents of the change tubes.

c). Accumulate credit Low value coins are inserted until a credit value is reached. The Coin Changer then sends the value to the VMC.

d). Float up function on Enable to allow float up levels. Coin “float” values are set on the “Coin Settings” page.

e). With high string protection Enabling high string protection will cause the Coin Changer to send the next 100 coins to the cashbox if the string sensor is triggered.

f). Tube Counter with security stock Check Tube Counter’s security stock, including the security stock values, to transmit tube contents to the VMC.

g). No correction of tube counters to disable the automatic Coin Changer Coin Tube Sensors.

m). “Tube empty” function for bills Check this function to disable acceptance of high value bills when the Coin Changer is empty.

5.Select Inhibit Mask… on the screen to enable or disable coin/bill acceptance (See Figure 12-6 a).

a). Select the tick box next to each denomin- ation that is to be disabled (See Figure 12- 6 b).

a

b

c

Figure 12-6Inhibit Coin Channels Mode

b). Select to program the Coin

Changer or to return to the

screen (See Figure 12-6 c). 6. Setting the Changer’s “Float Level”.

a). Configure the “Float Level” for each coin denomination by using the triangular “up” and “down” pointing arrows on the screen (See Figure 12-7 a).

b). Click to program the Coin Changer (See Figure 12-7 b).

a

b

Figure 12-7Float Level Mode

5900335 © 2005 JCM-American Corporation

1 2 - 2

Image 40
Contents OptipayTM CC Page Optipay CC Cleaning Transport Technical Data List of Figures LOFThis page Intentionally Left Blank List of Tables LOTOptipay CC List of Tables General Information General InformationService Tools General Information Concerning Coin ChangerAdvantages PC Test StationConfiguration Tools Update ToolsOptipay CC Protecting Yourself and the Equip- ment Safety InstructionsProper use This page Intentionally Left Blank Coin Validator DesignDevice Overview DIP Switch Block Return LeverKeyboard Pilot LightsProduct Labels Payout UnitTube Cassette Payout Module MDB Vending Machine CableFilling Level Sensors Configuring Change Tube Coin Maximum FunctionsConfiguring Tokens Resetting the Tube CounterSecurity Stock Considerations Inhibiting Certain Coin TypesIndividual Wake-up Time Consider- ations Minimizing String Manipulation optionalThis page Intentionally Left Blank Installation 1Coin Validator RemovalInstallation Energizing 1Coin Validator KeyboardThis page Intentionally Left Blank Emptying the Change Tubes to a Certain Fill Level OperationValidator Change Filling Inhibiting Coin Types Using DIP Switch Block Settings 2Coin Validator Switch BlockCleaning 1Opening and Closing the Coin Validator’s Access PanelThis page Intentionally Left Blank Transport This page Intentionally Left Blank Specifications Technical DataCE Certification This page Intentionally Left Blank Configuration Workshop Testing the Coin ChangerWorkshop Testing and/or Configur- ing the Coin Changer PC Programming Station and Palm Pilot Handheld UseWhich Functions Can be Config- ured? WinEMP SoftwarePalmA66 Software PalmEMP SoftwareConnecting a Palm Pilot Handheld 1PC Programming Station ConnectionThis page Intentionally Left Blank Managing Coin and Configuration Set- tings RequirementsSet functions listed in -5 a through h Enabling the Bill Recycler Select Tab on Changer Service, Token Programming, and Currency Conversion Gramming within the menu Changer Diagnostics 18Conversion Setting ModeIndex DisclaimerLED PalmE66 Testing requirements conditions for… NumericsFront Panel LED Indicators Trouble ShootingQuick Pilot Light Diagnosis Diagnosis Using a Palm Pilot Set- ting Module Display Meaning TroubleDisplay Meaning Trouble Optipay CC Trouble Shooting Coin Changer GlossaryGlossary of Terms Optipay CC Glossary May 5900335