C. Crane A-66 manual Requirements, Managing Coin and Configuration Set- tings

Page 39

OptipayCC

A-66 Coin Changer

S e c t i o n 1 2

12PALM PILOT® USAGE A66US Changer Program Usage

This section describes the use of a Palm Pilot® to configure the Optipay™ CC A-66 Coin Changer

using PalmA66© and/or PalmEMP© software.

Requirements

A Palm Pilot® Handheld – All M100, 500 and Tungsten Series handhelds (See Figure 12-1)

Centaur Changer Communication Cable

JCM A66US Changer Program for the Palm Pilot®*

PC with Windows 2000 or XP O/S

Palm Pilot® Application Suite

Hot Sync Cradle or Cable*.

*Refer to the Palm Pilot® user’s manual for program installation and Hot Sync instructions.

a

Figure 12-2Palm A66US Selection

Managing Coin and Configuration Set- tings

1.Turn on the Palm Pilot® and select the JCM Palm A66US application (See Figure 12-2).

2.Select the Settings tab on the main menu screen (See Figure 12-3 a).

3.Select the Operating modestab on the

menu screen (See Figure 12-4 a).

a

Figure 12-3Selecting Settings

a

Figure 12-1Typical M100/500 Series Palm

Figure 12-4Selecting Mode

Pilot® Handheld & Software

5900335 © 2005 JCM-American Corporation

1 2 - 1

Image 39
Contents OptipayTM CC Page Optipay CC Cleaning Transport Technical Data LOF List of FiguresThis page Intentionally Left Blank LOT List of TablesOptipay CC List of Tables General Information General InformationPC Test Station Service ToolsGeneral Information Concerning Coin Changer AdvantagesUpdate Tools Configuration ToolsOptipay CC Safety Instructions Protecting Yourself and the Equip- mentProper use This page Intentionally Left Blank Design Coin ValidatorDevice Overview Pilot Lights DIP Switch BlockReturn Lever KeyboardPayout Unit Product LabelsTube Cassette MDB Vending Machine Cable Payout ModuleFilling Level Sensors Functions Configuring Change Tube Coin MaximumInhibiting Certain Coin Types Configuring TokensResetting the Tube Counter Security Stock ConsiderationsMinimizing String Manipulation optional Individual Wake-up Time Consider- ationsThis page Intentionally Left Blank 1Coin Validator Removal InstallationInstallation 1Coin Validator Keyboard EnergizingThis page Intentionally Left Blank Operation Emptying the Change Tubes to a Certain Fill LevelValidator Change Filling 2Coin Validator Switch Block Inhibiting Coin Types Using DIP Switch Block Settings1Opening and Closing the Coin Validator’s Access Panel CleaningThis page Intentionally Left Blank Transport This page Intentionally Left Blank Technical Data SpecificationsCE Certification This page Intentionally Left Blank PC Programming Station and Palm Pilot Handheld Use ConfigurationWorkshop Testing the Coin Changer Workshop Testing and/or Configur- ing the Coin Changer PalmEMP Software Which Functions Can be Config- ured? WinEMP Software PalmA66 Software1PC Programming Station Connection Connecting a Palm Pilot HandheldThis page Intentionally Left Blank Requirements Managing Coin and Configuration Set- tingsSet functions listed in -5 a through h Enabling the Bill Recycler Select Tab on Changer Service, Token Programming, and Currency Conversion Gramming within the menu 18Conversion Setting Mode Changer DiagnosticsDisclaimer IndexLED PalmE66 Numerics Testing requirements conditions for…Trouble Shooting Front Panel LED IndicatorsQuick Pilot Light Diagnosis Display Meaning Trouble Diagnosis Using a Palm Pilot Set- ting ModuleDisplay Meaning Trouble Optipay CC Trouble Shooting Glossary Coin ChangerGlossary of Terms Optipay CC Glossary May 5900335