6 ENERGIZING

This section provides energizing (power-up) instructions for the Optipay™ CC A-66 Coin Changer.

Although the individual functions of the A-66 Coin Changer are pre-programmed by the manufacturer to customer specifications, the first time the device is activated, the four Tube Cassette change tubes must be filled with relevant coin types.

In many cases the Vending Machine’s controls will offer a filling function. In this case they should be used, because the control unit might not accept the filling level capacity of the Coin Changer.

If the Cash Box contains coins, it must be emptied, otherwise new coins directed to the Cash Box will not be counted.

To begin the energizing process:

1.Press the Plus key (See Figure 6-1 [4]). An audible signal will sound and the Green LED (See Figure 6-1 [1]) will begin flashing indicating that the Coin Changer is no longer in a standard operating mode and has now entered the filling level mode.

2.Insert the coin tubes.

The Coin Validator’s tube counter meters in the accepted coins, and the Coin Changer sorts the corresponding coin type into its pre- configured tube until either:

The full sensor is covered, or

The maximum coin number is configured, or

The float level is reached.

If the “float” function is active, tube coins inserted thereafter will not be accepted and will be directed to the return area tray.

Otherwise, they will be accepted and directed to the Cash Box.

If all the coin tubes are full:

3.Press the Plus key again.

Two audible signals will sound and the Green LED will light constantly indicating that the Coin Changer is no longer in the filling level mode and has returned to the operating mode.

If no coins are inserted in a 30 second time period, the Coin Changer will automatically return to the operating mode, without having to press the Plus key a second time.

Figure 6-1Coin Validator Keyboard

5900335 © 2005 JCM-American Corporation

6 - 1

Image 25
Contents OptipayTM CC Page Optipay CC Cleaning Transport Technical Data LOF List of FiguresThis page Intentionally Left Blank LOT List of TablesOptipay CC List of Tables General Information General InformationGeneral Information Concerning Coin Changer Service ToolsAdvantages PC Test StationUpdate Tools Configuration ToolsOptipay CC Protecting Yourself and the Equip- ment Safety InstructionsProper use This page Intentionally Left Blank Coin Validator DesignDevice Overview Return Lever DIP Switch BlockKeyboard Pilot LightsProduct Labels Payout UnitTube Cassette Payout Module MDB Vending Machine CableFilling Level Sensors Functions Configuring Change Tube Coin MaximumResetting the Tube Counter Configuring TokensSecurity Stock Considerations Inhibiting Certain Coin TypesMinimizing String Manipulation optional Individual Wake-up Time Consider- ationsThis page Intentionally Left Blank 1Coin Validator Removal InstallationInstallation 1Coin Validator Keyboard EnergizingThis page Intentionally Left Blank Emptying the Change Tubes to a Certain Fill Level OperationValidator Change Filling 2Coin Validator Switch Block Inhibiting Coin Types Using DIP Switch Block Settings1Opening and Closing the Coin Validator’s Access Panel CleaningThis page Intentionally Left Blank Transport This page Intentionally Left Blank Specifications Technical DataCE Certification This page Intentionally Left Blank Workshop Testing the Coin Changer ConfigurationWorkshop Testing and/or Configur- ing the Coin Changer PC Programming Station and Palm Pilot Handheld UseWinEMP Software Which Functions Can be Config- ured?PalmA66 Software PalmEMP Software1PC Programming Station Connection Connecting a Palm Pilot HandheldThis page Intentionally Left Blank Requirements Managing Coin and Configuration Set- tingsSet functions listed in -5 a through h Enabling the Bill Recycler Select Tab on Changer Service, Token Programming, and Currency Conversion Gramming within the menu 18Conversion Setting Mode Changer DiagnosticsDisclaimer IndexLED PalmE66 Numerics Testing requirements conditions for…Front Panel LED Indicators Trouble ShootingQuick Pilot Light Diagnosis Display Meaning Trouble Diagnosis Using a Palm Pilot Set- ting ModuleDisplay Meaning Trouble Optipay CC Trouble Shooting Glossary Coin ChangerGlossary of Terms Optipay CC Glossary May 5900335