Optipay™ CC
A-66 Coin Changer
A p p e n d i x A
A TROUBLE SHOOTING
If a Coin Changer fault occurs, the pilot lights at the top of the Coin Validator will indicate the fault’s location.
The following JCM diagnostic service tools are available to detail diagnose the fault’s cause (see the "Diagnosis Using the Setting Module" area in this appendix, as well as the in related information located in sections 1 and 11 of this manual).
Front Panel LED Indicators
If the Green LED at the top of the Coin Validator is lit or is flashing, no faults are indicated and the device is working properly (See Figure
If the Yellow LED in the middle of the Coin Validator flashes there is a definite fault which generally can be easily remedied.
If the Red LED at the bottom of the Coin Validator flashes, a fault that must be remedied by a service technician is probable.
The label at the top of the Coin Validator may help in locating the fault and Table
Quick Pilot Light Diagnosis
Figure A-1 Quick Diagnosis with the Help of the Pilot Lights
Table
LED | Meaning | Trouble |
|
|
|
|
|
|
Green Lit | Coin changer | No error |
| operational |
|
Green | Filling level | No error |
Flashing | mode active |
|
Green & | Inserted coin | Check vending machine |
Yellow Lit | inhibited | settings (a possibility |
| from the | that high value coins |
| Vending | were inhibited as tube is |
| Machine | empty) |
Table
LED | Meaning | Trouble |
|
|
|
|
|
|
Green & | Inserted coin | Activate coin channel |
Red Lit | inhibited | using switching block or |
| from the | Palm Setting Module |
| Vending | with WinEMP© or Palm |
| Machine | Pilot® with PalmA66© |
Yellow | Return lever | Check return mecha- |
Flashes | pressed or | nism in Vending |
once | switch in Coin | Machine or |
| Validator | Service case |
| defective |
|
5900335 © 2005
A - 1