Menu Selection and Settings
Menu Selection Setting Table
  | Func No. | Function | Setting Range | Default | 
  | 
  | Memory Group 1 Channels  | 1 ~ 99  | 01 ~ 99  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Memory Group 2 Channels  | 0 ~ 99  | OFF  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Memory Group 3 Channels  | 0 ~ 99  | OFF  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Memory Group 4 Channels  | 0 ~ 99  | OFF  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Memory Group 5 Channels  | 0 ~ 99  | OFF  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Quick Memory Channel Banks  | 1 ~ 5  | 5  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | –  | –  | –  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | [AuB] Auto Channel Up  | ON/OFF | OFF  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | EDSP | ON/OFF  | ON  | 
  | |
  | 2/4  | 4  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | Shuttle Jog Dial Speed  | 1 mS ~ 100 mS  | 50 mS  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | IF SHIFT/WIDTH Step Size  | 10/20 Hz  | 10 Hz  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Main   | 0.62(5)/1.25/2.50/5.00/10.00/20.00Hz  | 10.00 Hz  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | SUB   | 0.62(5)/1.25/2.50/5.00/10.00/20.00Hz  | 10.00 Hz  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Channel Step Size  | 1 ~ 100 kHz  | 10 kHz  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Quick Split Offset  | (±) 1 ~ 100 kHz  | 5 kHz  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Automatic Selection of the  | ON/OFF  | OFF  | 
  | |
  | 
  | AGC Decay Time  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | CLAR   | ON/OFF  | ON  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | CLAR Tuning Step Size  | 0.62(5)/1.25/2.50/5.00/10.00/20.00Hz  | 10.00 Hz  | 
  | |
  | Scan Pause  | ON/OFF  | ON  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Scan Resume Mode  | CAR STOP/CAR TIME/CAR SLOW | CAR STOP | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | –  | –  | –  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Memory Scan Speed (Dwell Time)  | 100 mS ~ 1000 mS (1S)  | 200 mS  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | VFO Scan Speed (Dwell Time)  | 1 mS ~ 100 mS  | 10 mS  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Auto Memory Write  | OFF/GROUP 1/ GROUPS ALL  | OFF  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Memory Scan Skip  | OFF/OFF  | OFF  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Scan Delay Time  | 1 S ~ 10 S  | 5 S  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Noise Blanker  | A1 ~ A15 & B1 ~ B15  | A12  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | NOTCH Mode  | IF NOTCH/AUTO DSP/SELECT  | IF NOTCH  | 
  | |
  | Frequency Display  | OFFSET/CARRIER  | OFFSET  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Display Resolution  | 10 Hz/100 Hz/1000 Hz (1 kHz)  | 10 Hz  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | ETS (Enchanced Tuning Scale)  | CLAR/DIAL  | CLAR  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Transverter Frequency Display  | OFF/50/144/430  | OFF  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Dimmer (Display Brightness)  | LOW/HI  | HI  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Panel Display Mode  | CLAR/CH FREQ/OFFSET/CW PITCH  | CLAR  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | SUB   | ON/OFF  | ON  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | MAIN   | OFF/10 mS ~ 2000 mS (2S)  | OFF  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | SUB   | OFF/10 mS ~ 2000 mS (2S)  | OFF  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | –  | –  | –  | 
  | |
  | RF Output Power (Limit)  | 200/75/10 W  | 200 W  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | Key & Panel Beeper  | ON/OFF  | ON  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
page 108  | 
 |