Vertex Standard FT-1000MP manual Rpt, 8AH, Vfo, 8CH, 8DH, 8EH, F7H, F9H

Page 98

CAT System Computer Control

Opcode Command Chart (3)

 

Command

Parameter Bytes

Opcode

 

Parameter Description

 

 

 

 

 

 

 

 

 

 

or Key

1st

2rd

3rd

4th

5th

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TUNER

T

81H

Switch Antenna Tuner ON (T = 01H) or OFF (T = 00H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tuner Start

82H

Start Antenna Tuning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dual Operation

D

83H

Switch Dual Receive ON (D = 01H) or OFF (D = 00H)

 

 

 

 

 

 

 

 

 

 

 

[RPT]

R

84H

Switch Simplex Operation (R = 00H), Minus Shift (R = 01H),

 

 

or Plus Shift (R = 02H) for Repeater Operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[AuB]

85H

Copy Data Display in VFO-A or VFO-B.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set SUB

 

 

 

 

 

Enter new operating frequency in F1 ~ F4, in BCD format:

 

 

VFO-B

F1

F2

F3

F4

8AH

 

 

see text for example.

 

 

 

 

 

 

Operating Freq.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Select filter bandwidth for selected IF (see below):

 

 

BANDWIDTH

 

 

 

 

 

8.2 MHz

 

455 kHz

 

VFO

 

 

 

 

 

 

 

THRU: X4 = 09

6.0 kHz: X4 = 84

Both: X1 = 00

 

 

 

 

 

 

 

 

 

 

2ud & 3rd IF

X1

X4

8CH

2.4 kHz: X4 = 00 2.4 kHz: X4 = 80

VFO-A: X1 = 01

 

 

Filter Selection

 

 

 

 

 

2.0 kHz: X4 = 01

2.0 kHz: X4 = 81

VFO-B: X1 = 02

 

 

 

 

 

 

 

 

500 Hz: X4 = 02

500 Hz: X4 = 82

 

 

 

 

 

 

 

 

 

 

500 Hz: X4 = 03

500 Hz: X4 = 83

 

 

 

 

 

 

 

 

 

 

 

 

 

MEM. Channel

S

X

8DH

Tag memory channels 1 thruogh 99 (X = 01H ~ 6CH), to be

 

 

Scan Skip

skipped (S = 01H) or included (S = 00H) while scanning.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step VFO-A

T

8EH

Step frequency of VFO-A UP (T = 00H) or DOWN (T = 01H)

 

 

UP/DOWN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Select one of 33 CTCSS subaudible tones

 

 

 

 

 

 

 

 

where E = 00H ~ 20H

 

 

 

 

 

 

 

 

 

 

 

 

E = 00H

67.0 Hz

 

E = 0BH 118.8 Hz

E = 16H 173.8 Hz

 

 

 

 

 

 

 

 

E = 01H

71.9 Hz

 

E = 0CH 123.0 Hz

E = 17H 179.9 Hz

 

 

 

 

 

 

 

 

E = 02H

77.0 Hz

 

E = 0DH 127.3 Hz

E = 18H 186.2 Hz

 

 

CTCSS

 

 

 

 

 

E = 03H

82.5 Hz

 

E = 0EH 131.8 Hz

E = 19H 192.8 Hz

 

 

Encoder

E

E

E

E

90H

E = 04H

88.5 Hz

 

E = 0FH 136.5 Hz

E = 1AH 203.5 Hz

 

 

Tone Frequency

 

 

 

 

 

E = 05H

94.8 Hz

 

E = 10H

141.3 Hz

E = 1BH 210.7 Hz

 

 

Select

 

 

 

 

 

E = 06H 100.0 Hz

 

E = 11H

146.2 Hz

E = 1CH 218.1 Hz

 

 

 

 

 

 

 

 

E = 07H 103.5 Hz

 

E = 12H 151.4 Hz

E = 1DH 225.7 Hz

 

 

 

 

 

 

 

 

E = 08H 107.2 Hz

 

E = 13H 156.7 Hz

E = 1EH 233.6 Hz

 

 

 

 

 

 

 

 

E = 09H 110.9 Hz

E = 14H 162.2 Hz

E = 1FH 241.8 Hz

 

 

 

 

 

 

 

 

E = 0AH 114.8 Hz

E = 15H 167.9 Hz

E = 20H 250.3 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instruct radio to return digitized indications of various meter

 

 

 

 

 

 

 

 

level readings and front panel control settings (4 repeated

 

 

 

 

 

 

 

 

bytes, and F7H) selected by:

 

 

 

 

 

 

 

 

 

 

 

M = 00H Main S-Meter

M = 87H TUN Meter

 

 

Read Meter &

 

 

 

 

 

M = 01H Sub S-Meter

M = F0H Shuttle Jog Dial

 

 

F7H

M = 80H PO Meter

 

M = F1H CW Pitch Setting

 

 

Panel Controls

 

 

 

 

 

 

 

 

M = 81H ALC Meter

M = F2H Remote Control A/D Level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M = 83H IC Meter

 

M = F3H SHIFT Setting

 

 

 

 

 

 

 

 

M = 84H VCC Meter

M = F4H WIDTH Setting

 

 

 

 

 

 

 

 

M = 85H SWR Meter

M = F5H EDSP Contour Selection

 

 

 

 

 

 

 

 

M = 86H MIC Meter

M = F6H EDSP NR Selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set offset for RPT shift, valid values are

 

 

 

Repeater

X1

X2

X3

X4

F9H

0 ~ 500 kHz in 1-kHz step. Use BCD format for X2 ~ X4.

 

 

Offset

X1 is 10’s & 100’s of Hz

 

X2 is 1’s & 10’s of kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X3 is must be 00H, 01H, or 02H X4 is must be 00H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

page 96

MARK-V FT-1000MP Operating Manual

Image 98
Contents Vertex Standard Yaesu Europe B.VTabel of Contents General Description MARK-V FT-1000MP Operating ManualMARK-V FT-1000MP Operating Manual Transmitter SpecificationsGeneral ReceiverPLUG/CONNECTOR Pinout Diagrams Accessories & Options Supplied AccessoriesOptional Sub Receiver Filter If Crystal Filter OptionsOptional Main Receiver Filters Available OptionsGround Connections Safety PrecautionsPower Connections RF Field Exposure Advisory & Electromagnetic Compatibility Antenna PrecautionsElectrical Shock Prevention Preliminary Inspection General SetupFP-29 Transceiver LocationAntenna Considerations Adjusting the Front FeetMemory Backup RG-8XQSK Accessory InstallationLinear Amplifier Interfacing Operation with QSK AmplifiersOperation with NON-QSK Amplifiers FL-2100SERIES or Others About ALC Transverter Operation Digital Modem TNC, WEATHERFAX, ETC. Interfacing Digital Modes with a TNC Or Computer Sound Card PSK-31MARK-V FT-1000MP TNC Accessory Installation Accessory Installation Other DIGITAL/RECORDING Device Interfacing FeaturesConfiguration Suggestions CW KEY/PADDLE and Computer Keying Interface SuggestionsLarge Receive Antennas Antenna ConnectionsPersonal Computer Interfacing for Contest SOFTWARE, ETC Front Panel Controls SUB AF Knob AF Gain RF Gain KnobRF PWR Knob Moni KnobCLASS-A Button Mode Selection ButtonsEdsp Filters Fast ButtonShuttle Jog and VRF & Idbt Buttons Main VFO-A Tuning KnobMain VFO-A RX & TX Switch-LED AF REV ButtonVFO & Memory Control Band KeypadSUB SQL Knob SUB VFO-B RX & TX Switch-LEDLock Button CW and Electronic Keyer ControlsNB Button NOR NAR ModeBandwidth Buttons NOR/NAR1/NAR2 Buttons 2nd and 3rd if Filter BandwidthVRF/MEM CH Knob VRF IndicatorTuner Button VRF/MEM CH Knob SequenceLCD Bargraph Meter Indications Wait Sub Receiver ModeMEM F HI SWRTOP Panel Access & Controls 12. CW PKTRtty Additional NoteCW Sidetone Trimmer Rear Panel Controls & ConnectorsRemote Jack Packet DIN JackBand Data DIN Jack DC in JackBefore Starting OperationKey Beeper Menu ProgrammingSpecial Note for CW Mode Reverse CW sideband Mode SelectionFast Button Operation VFO KnobShuttle Jog VRF/MEM CHMicrophone Up/Dwn Buttons Display SettingsPanel Up/Down Buttons VFO Channel SteppingVFO Selection & Receiver Muting Alternate VFO Operation Front & RearevfoToggle VFOs Keypad Frequency EntryRTTY/PKT Tuning Signal Tuning Meter IndicationsCW Tuning AM Synchronous Tuning SUB-DISPLAY Mode Selection Expanded Tuning ScaleAM Synchronous Tuning Meter Frequency Band Range MHz AM Broadcast ReceptionGeneral Coverage Reception Dealing with Interference Receiver Front End Configuration For illustrative purposesWide Band and Tuned Preamp Selection VRF Variable RF FRONT-END FilterAGC Automatic Gain Control Selection RF Gain SettingIPO Intercept Point Optimization If Filter Bandwidth Selection There are two banks of select Main receiver VFO-A if Bandwidth Filter SelectionNoise Blanker Width Action Using Width control to reduce QRM Width ControlIf Shift Action SHIFT/WIDTH Tuning StepsUsing if Shift to reduce QRM Notch FilterAdvice on QRM Reduction Clarifier RX/TX Offset TuningClarifier Settings Offset Display ModeBand TX Range TransmittingAntenna Selection Selecting AntennasSSB Transmission Important NoteTransmitter Monitor Class-A Operation Microphone Tone SelectionRF Speech Processor Carrier Point OffsetCW Transmission VOX Operation Voice-Actuated T/R Switching OperationStraight-Key Operation CW Straight Key and Paddle Connections Electronic Keyer OperationACS Auto Character Spacing Keyer Settings CW Pitch Setting and Spot ToneBaud Packet Digital Mode OperationRtty Operation AM TransmissionTNC Tone Pair Tone Center Frequency Packet OperationBaud FM Packet FM Repeater Operation FM TransmissionMain and Sub VFO Audio Dual ReceptionUsing Headphones for Dual Receive Headphone Audio AdjustmentsSplit Frequency Operation Split Operation ModeSUB VFO-B Settings VFO Tracking Sideband Diversity ReceptionBandwidth Diversity Reception Memory Features Memory StructureRegarding the VRF/MEM CH Knob Basic Memory Storage ProcedureAuto Channel-Up Memory ProgrammingMemory Checking Memory TuningRecalling & Operating on Memory Channels Copying Between Memories Limiting Memory Group OperationCopying a Selected Memory to VFO-A Grouping Memories QMB Quick Memory Bank Operation Memory Scanning Auto Memory WriteVFO Scanning Memory Scan SkipMemory Masking Scan Resume ModeScan Skip Disable Programmed Memory Scanning PMS Memories P1 ~ P9 Advanced Features Edsp Functions Edsp ModulationEdsp Contours Edsp RX Audio EnhancementEdsp Auto Multiple Notch Action Edsp Noise ReducerEdsp Auto Multiple Notch Filter Important Note About Edsp Introduction FeaturesRemote Control Operation Contest Keyer ControlUser Message Memories 1 Contest Number MemoryCQ or ID Memory Message StorageTune Mode Contest Keyer OperationIII. Main VFO-A Control II. VFO/MEMORY ControlComments USER-CUSTOMIZED Operating ModeOverview Sub VFO B Dial Main VFO a DialDVS-2 Controls Segment Message Recording PlaybackMessage Recording No Function SegmentMessage Transmission Receiver Recording withSelecting Receiver Audio Message MonitorPhone Patch Operation OperationTuning Meter RE-CALIBRATION Packet TuningOpcode CAT 5-BYTE Command StructureOverview CAT Data Protocol CAT Data Byte FormatDATA/ARGUMENT Bytes Constructing and Sending CAT Commands50 H 03 H 00 H 81 H 09 H 0A HStatus Flags Bytes 1~ Status Update Data OrganizationDownloading Memory Channel Data ByteStatus Flag Byte #2 Contents Status Flag Byte #1 ContentsStatus Flag Byte #4 Contents Status Flag Byte #5 ContentsMemory Channel Data Hex Codes Byte Data Record Structure Rtty PKT Coding Examples 0CH Opcode Command Chart0AH 0EHEdsp Command Parameter Bytes Opcode Or Key 1st 2rd 3rd 4th 5th70H 75HVFO RPT8AH 8CHFAH Byte Format F = 00H Byte Format F = 01HGrP3-cH GrP1-cHGrP2-cH GrP4-cHDiAL-SPd Auto-uPEdSP SJ-SPEEdSc-dL-ti Auto-inScAn-ALL NotcHBEEP SP-HoLdNot Used RF out BEEP-FSub-FiL CW norDAtAnAr2 FiLTonE SEt PAc-tonENot Used CtcSS RPt-SHFtLock-SEL Rc-FuncFASt-SEt PA-cntTunEr USEr-SEtSub-AGc CAr oFStCustom Frequency & Display Offset Information 1st Fc = F + 70.455 BFO kHzKHz 500 Hz 250 Hz PKT-F UserMenu Selection Setting Table Func No Function Setting Range DefaultSEPARATE/BALANCE Separate Main VFO-A/SUB VFO-BMONO/STEREO 1/STEREO Stereo NORMAL/REVERSE NormalDefault User Function Settings LSB USB CW USB CW LSB Rtty LSB Rtty USB PKT LSBTX PLL Easy Set Mode SettingsRX PLL Installing Internal Accessories TCXO-6 InstallationMain Receiver 2ND and 3RD if Filters Filter InstallationInstallation SUB Receiver CW Narrow FilterMemory BACK-UP Switch Lithium Battery ReplacementInternal 13.8V Fuse Replacement POWER-ON Microprocessor Reset Procedures MARK-V FT-1000MP Operating Manual