Vertex Standard FT-1000MP manual CW nor, DAtAnAr2, Sub-FiL, RttY-SHF, RttY-PoL, RttY-ton, RtY-FdSP

Page 104

Menu Selection and Settings

5-2 CW nor

5-7 455-250

CW Normal Filters - Selects the CW filters used when the front-panel [NOR] switch is selected (while in the CW mode).

8.2- Sets the 2nd IF to the optional 2.0 kHz filter, and the 3rd IF to the 2.4 kHz filter.

455 - Sets the 2nd IF to the 2.4 kHz filter, and the 3rd IF to the optional 2.0 kHz filter.

8.2-455 - Sets the 2nd IF and 3rd IF filters to 2.0 kHz filter options.

Note: If you have not installed the optional 2.0 kHz filters (or if you disable the optional 2.0 kHz filters by menu selection 5-1and/or 5-5), the received signal will pass through the standard 2.4 kHz filter.

5-3 8.2-250

2nd IF 250 Hz Filter - Enables/disables the optional 250 Hz IF filter (Yaesu P/N YF-114CN).

5-4 dAtAnAr2

DATA Narrow 2 Filters - Selects the filters used when the front-panel [NAR2] switch is selected (while in the DATA mode).

8.2- Sets the 2nd IF to the optional 250 Hz filter, and the 3rd IF to the optional 500 Hz filter.

455 - Sets the 2nd IF to the 500 Hz filter, and the 3rd IF to the optional 250 Hz filter.

8.2-455 - Set the 2nd IF and 3rd IF filters to the 250 Hz filter options.

Note (1): If you have not installed the optional 2nd IF 500 Hz filter (or if you disable the filter by menu se- lections 5-3), the received signal will pass through the supplied 500 Hz filter.

Note (2): If you have not installed the optional 3rd IF 500 Hz filter (or if you disable the filter by menu se- lections 5-6), the received signal will pass through the supplied 2.4 kHz filter.

Note (3): If you have not installed the optional 3rd IF 250 Hz filter (or if you disable the filter by menu se- lections 5-7), the received signal will pass through the supplied 2.4 kHz (or optional 500 Hz) filter.

5-5 455-2.0

3rd IF 2.0 kHz Filter - Enables/disables the op- tional 2.0 kHz IF filter (Yaesu P/N YF-110SN).

3rd IF 250 Hz Filter - Enables/disables the optional 250 Hz IF filter (Yaesu P/N YF-110CN).

5-8 Sub-FiL

SUB VFO Filter - Enables/disables optional SUB VFO-B 2nd IF 500-Hz CW filter (Collins YF-115C).

5-9 t-FiL

TX EDSP Filter - Selects either a 6.0-kHz or 2.4- kHz digital bandpass filter for early-stage transmit au- dio tailoring.

6-0 rttY-SHF

RTTY Frequency Shift - Selects 170, 425, or 850 Hz standard frequency shift for FSK RTTY operation.

Important Note! - If changing RTTY shift to other than 170 Hz, be sure to re-calibrate the tuning meter as outlined on page 85. The calibration routine is simple, and ensures your center tuning indication matches the tone pair.

6-1 rttY-PoL

RTTY Polarity - Selects normal or reverse Mark/ Space polarity for RTTY operation. Normal operation utilizes a 2125-Hz mark frequency, while reverse uses 2295 Hz. See the table on page 17 for a list of stan- dard tone pairs.

6-2 rttY-ton

RTTY Tone - Selects high or low mark tone for RTTY operation. See the table on page 17 for a com- parison of high/low tone pairs.

6-3 rtY-FdSP

RTTY Frequency Display - Selects the type of dis- play offset that appears during RTTY operation.

Offset - Displays the RTTY BFO offset.

Carrier - Displays the actual carrier frequency.

6-4 PAc-FdSP

Packet Frequency Display Offset - You can off- set the frequency readout to display the center fre- quency between the two transmitted carriers (tone pairs). Rotate the MAIN VFO-A knob to adjust the dis- play offset, or else set to 0.00 to display the actual car- rier frequency. See menu selection 6-5below for tone pair selection.

5-6 455-500

3rd IF 500 Hz Filter - Enables/disables the optional 500 Hz IF filter (Collins YF-115C).

page 102

MARK-V FT-1000MP Operating Manual

Image 104
Contents Vertex Standard Yaesu Europe B.VTabel of Contents General Description MARK-V FT-1000MP Operating ManualMARK-V FT-1000MP Operating Manual Specifications GeneralTransmitter ReceiverPLUG/CONNECTOR Pinout Diagrams Accessories & Options Supplied AccessoriesIf Crystal Filter Options Optional Main Receiver FiltersOptional Sub Receiver Filter Available OptionsGround Connections Safety PrecautionsPower Connections RF Field Exposure Advisory & Electromagnetic Compatibility Antenna PrecautionsElectrical Shock Prevention General Setup FP-29Preliminary Inspection Transceiver LocationAdjusting the Front Feet Memory BackupAntenna Considerations RG-8XAccessory Installation Linear Amplifier InterfacingQSK Operation with QSK AmplifiersOperation with NON-QSK Amplifiers FL-2100SERIES or Others About ALC Transverter Operation Digital Modem TNC, WEATHERFAX, ETC. Interfacing Digital Modes with a TNC Or Computer Sound Card PSK-31MARK-V FT-1000MP TNC Accessory Installation Accessory Installation Features Configuration SuggestionsOther DIGITAL/RECORDING Device Interfacing CW KEY/PADDLE and Computer Keying Interface SuggestionsLarge Receive Antennas Antenna ConnectionsPersonal Computer Interfacing for Contest SOFTWARE, ETC Front Panel Controls AF Gain RF Gain Knob RF PWR KnobSUB AF Knob Moni KnobMode Selection Buttons Edsp FiltersCLASS-A Button Fast ButtonMain VFO-A Tuning Knob Main VFO-A RX & TX Switch-LEDShuttle Jog and VRF & Idbt Buttons AF REV ButtonVFO & Memory Control Band KeypadSUB VFO-B RX & TX Switch-LED Lock ButtonSUB SQL Knob CW and Electronic Keyer ControlsNOR NAR Mode Bandwidth Buttons NOR/NAR1/NAR2 ButtonsNB Button 2nd and 3rd if Filter BandwidthVRF Indicator Tuner ButtonVRF/MEM CH Knob VRF/MEM CH Knob SequenceLCD Bargraph Meter Indications Sub Receiver Mode MEM FWait HI SWRTOP Panel Access & Controls PKT Rtty12. CW Additional NoteRear Panel Controls & Connectors Remote JackCW Sidetone Trimmer Packet DIN JackBand Data DIN Jack DC in JackOperation Key BeeperBefore Starting Menu ProgrammingSpecial Note for CW Mode Reverse CW sideband Mode SelectionVFO Knob Shuttle JogFast Button Operation VRF/MEM CHDisplay Settings Panel Up/Down ButtonsMicrophone Up/Dwn Buttons VFO Channel SteppingAlternate VFO Operation Front & Rearevfo Toggle VFOsVFO Selection & Receiver Muting Keypad Frequency EntryRTTY/PKT Tuning Signal Tuning Meter IndicationsCW Tuning AM Synchronous Tuning SUB-DISPLAY Mode Selection Expanded Tuning ScaleAM Synchronous Tuning Meter Frequency Band Range MHz AM Broadcast ReceptionGeneral Coverage Reception Receiver Front End Configuration For illustrative purposes Wide Band and Tuned Preamp SelectionDealing with Interference VRF Variable RF FRONT-END FilterAGC Automatic Gain Control Selection RF Gain SettingIPO Intercept Point Optimization If Filter Bandwidth Selection There are two banks of select Main receiver VFO-A if Bandwidth Filter SelectionNoise Blanker Width Action Using Width control to reduce QRM Width ControlSHIFT/WIDTH Tuning Steps Using if Shift to reduce QRMIf Shift Action Notch FilterAdvice on QRM Reduction Clarifier RX/TX Offset TuningClarifier Settings Offset Display ModeTransmitting Antenna SelectionBand TX Range Selecting AntennasSSB Transmission Important NoteTransmitter Monitor Microphone Tone Selection RF Speech ProcessorClass-A Operation Carrier Point OffsetCW Transmission VOX Operation Voice-Actuated T/R Switching OperationStraight-Key Operation CW Straight Key and Paddle Connections Electronic Keyer OperationACS Auto Character Spacing Keyer Settings CW Pitch Setting and Spot ToneDigital Mode Operation Rtty OperationBaud Packet AM TransmissionTNC Tone Pair Tone Center Frequency Packet OperationBaud FM Packet FM Repeater Operation FM TransmissionMain and Sub VFO Audio Dual ReceptionUsing Headphones for Dual Receive Headphone Audio AdjustmentsSplit Frequency Operation Split Operation ModeSUB VFO-B Settings VFO Tracking Sideband Diversity ReceptionBandwidth Diversity Reception Memory Features Memory StructureBasic Memory Storage Procedure Auto Channel-UpRegarding the VRF/MEM CH Knob Memory ProgrammingMemory Checking Memory TuningRecalling & Operating on Memory Channels Copying Between Memories Limiting Memory Group OperationCopying a Selected Memory to VFO-A Grouping Memories QMB Quick Memory Bank Operation Auto Memory Write VFO ScanningMemory Scanning Memory Scan SkipMemory Masking Scan Resume ModeScan Skip Disable Programmed Memory Scanning PMS Memories P1 ~ P9 Advanced Features Edsp Modulation Edsp ContoursEdsp Functions Edsp RX Audio EnhancementEdsp Auto Multiple Notch Action Edsp Noise ReducerEdsp Auto Multiple Notch Filter Important Note About Edsp Features Remote Control OperationIntroduction Contest Keyer ControlContest Number Memory CQ or ID MemoryUser Message Memories 1 Message StorageTune Mode Contest Keyer OperationIII. Main VFO-A Control II. VFO/MEMORY ControlUSER-CUSTOMIZED Operating Mode OverviewComments Sub VFO B Dial Main VFO a DialDVS-2 Controls Message Recording Playback Message RecordingSegment No Function SegmentReceiver Recording with Selecting Receiver AudioMessage Transmission Message MonitorPhone Patch Operation OperationTuning Meter RE-CALIBRATION Packet TuningCAT 5-BYTE Command Structure Overview CAT Data ProtocolOpcode CAT Data Byte FormatConstructing and Sending CAT Commands 50 H 03 H 00 H 81 H 09 HDATA/ARGUMENT Bytes 0A HStatus Update Data Organization DownloadingStatus Flags Bytes 1~ Memory Channel Data ByteStatus Flag Byte #1 Contents Status Flag Byte #4 ContentsStatus Flag Byte #2 Contents Status Flag Byte #5 ContentsMemory Channel Data Hex Codes Byte Data Record Structure Rtty PKT Coding Examples Opcode Command Chart 0AH0CH 0EHCommand Parameter Bytes Opcode Or Key 1st 2rd 3rd 4th 5th 70HEdsp 75HRPT 8AHVFO 8CHFAH Byte Format F = 00H Byte Format F = 01HGrP1-cH GrP2-cHGrP3-cH GrP4-cH Auto-uP EdSP DiAL-SPd SJ-SPEEdAuto-in ScAn-ALLSc-dL-ti NotcHSP-HoLd Not Used RF outBEEP BEEP-FCW nor DAtAnAr2Sub-FiL FiLPAc-tonE Not Used CtcSSTonE SEt RPt-SHFtRc-Func FASt-SEtLock-SEL PA-cntUSEr-SEt Sub-AGcTunEr CAr oFStCustom Frequency & Display Offset Information 1st Fc = F + 70.455 BFO kHzKHz 500 Hz 250 Hz PKT-F UserMenu Selection Setting Table Func No Function Setting Range DefaultMain VFO-A/SUB VFO-B MONO/STEREO 1/STEREO StereoSEPARATE/BALANCE Separate NORMAL/REVERSE NormalDefault User Function Settings LSB USB CW USB CW LSB Rtty LSB Rtty USB PKT LSBTX PLL Easy Set Mode SettingsRX PLL Installing Internal Accessories TCXO-6 InstallationFilter Installation InstallationMain Receiver 2ND and 3RD if Filters SUB Receiver CW Narrow FilterMemory BACK-UP Switch Lithium Battery ReplacementInternal 13.8V Fuse Replacement POWER-ON Microprocessor Reset Procedures MARK-V FT-1000MP Operating Manual