Goodman Mfg RT6100004R13 manual 036

Page 11

PRODUCT IDENTIFICATION

 

 

 

 

 

G

S

C

14

036

1

A

A

BRAND:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MINOR

G: Goodman® Brand /

 

 

 

 

 

 

 

 

 

 

 

REVISION:

Amana® Brand Distinctions

 

 

 

 

 

 

 

 

 

 

 

A: Initial Release

 

SEER:

 

 

 

A: Amana® Brand

 

 

10: 10 SEER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V: Value

 

 

13: 13 SEER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14: 14 SEER

 

 

 

 

 

MAJOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REVISION:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A: Initial Release

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOMINAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITY:

 

 

 

 

 

PRODUCT

 

 

 

 

 

018: 1.5 Tons

 

 

 

 

 

CATEGORY:

 

 

 

 

 

024: 2 Tons

 

 

 

 

 

S: Split System

 

 

 

 

 

030: 2.5 Tons

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036: 3 Tons

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042: 3.5 Tons

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048: 4 Tons

 

 

 

 

 

 

 

 

UNIT TYPE:

 

 

 

 

 

 

 

C: Condenser R-22

 

 

060: 5 Tons

 

 

 

 

 

 

 

 

H: Heat Pump R-22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL:

 

 

 

 

 

 

 

 

 

 

 

 

1:

208-230V/1ph/60Hz

 

 

 

 

 

 

 

 

 

 

 

 

3:

208-230v/3ph/60Hz

 

 

 

 

 

 

 

 

 

 

 

 

4:

460v/3ph/60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

PKF

PRODUCT CATEGORY:

C: Split System

UNIT TYPE:

E:Commercial Air Conditioner

K:Air Cojditioner

P:Heat Pump

036

2

A

REVISION:

A: Revision

ELECTRICAL:

1:208-230V/1ph/60Hz

2:220-240V/1ph/50 Hz

3:208-230v/3ph/60Hz

4:308/415V/3ph/50Hz

 

NOMINAL CAPACITY:

 

018: 1.5 Tons

048:

4

Tons

024:

2

Tons

060:

5

Tons

030: 2.5

Tons

070:

5

Tons

036:

3

Tons

090: 7.5 Tons

042: 3.5

Tons

120:

10 Tons

 

 

 

 

 

 

11

Image 11
Contents Service Instructions Important Information Table of ContentsSafe Refrigerant Handling Split System Air Conditioners R-22 Product IdentificationSplit System Air Conditioners R-22 Split System Heat Pumps R-22 Product Identification Single Piece Air Handlers Single Piece Air Handlers MBR/MBE Air Handlers 036 036 120 3642 1824 ASC01 AccessoriesCPKF24 CPKF36 CPKF42 CPKF48 CPKF60 CPKF61 Expansion Valve Kits FSK01A Coil Accessories Condensing Unit Product DesignProduct Design Heating System OperationCooling Cycle System Operation Indoor Coil Outdoor Thermostatic Expansion Valve Description AFE18-60A Control BoardCOOLING/HP Analysis Chart Troubleshooting ChartServicing Table of Contents Servicing Checking Voltage Checking WiringChecking THERMOSTAT, WIRING, and Anticipator 3A Thermostat and Wiring3C Heating Anticipator 3B Cooling AnticipatorChecking Cycle Protector Checking Time Delay RelayTesting Coil Circuit Checking Transformer Control CircuitChecking Contactor Contacts Testing Compressor ContactorTesting FAN Relay Checking Contactor AND/OR RelaysApplies to ASC13 & ASH13 Copeland Comfort Alert DiagnosticsRed Trip Diagnostics TableChecking Capacitor Hard Start KIT WiringTesting Capacitor Resistance Checking Loss of Charge Protector16B Checking FAN and Blower Motor ECM Motors Testing Capacitance15B Capacitance Check 16A Checking FAN and Blower Motor Windings PSC Motors16C Checking ECM Motor Windings 16D ECM CFM AdjustmentsChart on Next Chart from Previous Itc h GE X13TM Motor Connections 16E Checking GE X13TM MotorsChecking Compressor 17A Resistance TestCompressor Ground Test Testing Compressor Windings17B Ground Test 17D Operation TestChecking Reversing Valve and Solenoid Testing Crankcase Heater Optional ItemTesting Defrost Control Testing Defrost ThermostatAR*F & MBR With Single Stage Heat Pumps 40 AR*F & MBR Electronic Blowers Time Delay RelaySequence of Operation AR*F & MBR With Single Stage Condensers41 AEP* & MBE with Single Stage CON Densers AEP* & MBE Electronic Blower Time Delay Relay41A AEP* & MBE with Single Stage Heat Pumps Electric Heater Optional Item 61A Checking Heater Limit Controls Temperature Rise F @ CFMRefrigeration Repair Practice Leak Testing Nitrogen or NITROGEN-TRACED61B Checking Heater Fuse Link Optional Electric Heaters Checking Heater ElementsEvacuation EvacuationCharging An inaccurately charged system will cause future prob- lems Checking Compressor Efficiency105B Thermostatic Expansion Valve Thermostatic Expansion Valves OverfeedingUnderfeeding SuperheatChecking Expansion Valve Operation Checking SubcoolingCompressor Burnout Overcharge of RefrigerantChecking Restricted Liquid Line NON-CONDENSABLESRefrigerant Piping Suction Line Drier Clean-Up MethodInstallation Requirements System Charging Reversing Valve ReplacementStatic Pressure Drop AIR Handler External StaticCoil Static Pressure Drop Total External StaticALL Fuel System Control Board AFE18-60A Accessories Wiring DiagramsALL Fuel System AFE18-60A Control Board 10kw and Below, One Stage Electric Heat OT/EHR18-60 #2 GRD PLM PLF XFMR-R XFMR-C After Installing Optional Heat KIT, Mark AN X Provided Above HKR Heat Kit GRD PLM PLF Accessories Wiring Diagrams