Goodman Mfg RT6100004R13 manual Split System Air Conditioners R-22

Page 5

PRODUCT IDENTIFICATION

Split System Air Conditioners R-22

Model #

Description

 

 

GSC140**1AA

Goodman® Brand Split Condenser 14 Seer condensing units. Introduces Goodman®

Brand 14 Seer AC R-22 models.

 

 

 

GSC140**1AB

Goodman® Brand Split Condenser 14 Seer condensing units. New revisions have screw

locations moved in the top panel, base pans, louvers, and control box covers.

 

 

 

GSC140**1AC

Goodman® Brand Split Condenser 14 Seer condensing units. Release models

containing the Broad Ocean motor 0131M00060 and 0131M00061

 

 

 

GSC140**1AD

Goodman® Brand Split Condenser 14 Seer condensing units. Revise condenser coils by

removing (1) hairpin. Reducing refrigerant quantities by 6 ounces.

 

 

 

GSC14018-421BA

Goodman® Brand Split Condenser 14 Seer condensing units. Conversion of existing

models using 3/8" diameter tube coils to 5 mm coils.

 

 

 

 

Split System Air Conditioners R-22

 

 

 

Model #

 

Description

 

 

 

ASC130**1AA

Amana® Brand Split Condenser 13

Seer condensing units. Initial release new models of

Amana® Brand Deluxe 13 Seer AC R-22 conditioners.

 

ASC130**1AB

Amana® Brand Split Condenser 13

Seer condensing units. Move location of screw hole.

 

 

 

ASC130**1AC

Amana® Brand Split Condenser 13

Seer condensing units. Introduces horizontal style

louvers.

 

 

 

ASC1301**1AD

Amana® Brand Split Condenser 13 Seer condensing units. Remove 1 hairpin from coil.

 

 

ASC130601BD

Special High Feature Split XCondenser 14 Seer condensing units.. Remove 1

hairpin from coil. Reduce refrigerant quantities by 6 ounces.

 

 

 

 

 

Split System Air Conditioners R-22

 

 

Model #

Description

 

 

VSC13018-601AA

Value Split Condenser 13 Seer condensing units. Introduces Value 13 Seer AC R-22

models. 2 year part & 5 year compressor warranty in Bahama Beige.

 

 

 

5

Image 5
Contents Service Instructions Important Information Table of ContentsSafe Refrigerant Handling Split System Air Conditioners R-22 Product IdentificationSplit System Air Conditioners R-22 Split System Heat Pumps R-22 Product Identification Single Piece Air Handlers Single Piece Air Handlers MBR/MBE Air Handlers 036 036 120 3642 1824 ASC01 AccessoriesCPKF24 CPKF36 CPKF42 CPKF48 CPKF60 CPKF61 Expansion Valve Kits FSK01A Coil Accessories Condensing Unit Product DesignProduct Design Heating System OperationCooling Cycle System Operation Indoor Coil Outdoor Thermostatic Expansion Valve Description AFE18-60A Control BoardCOOLING/HP Analysis Chart Troubleshooting ChartServicing Table of Contents Checking THERMOSTAT, WIRING, and Anticipator Checking Voltage Checking Wiring3A Thermostat and Wiring Servicing3C Heating Anticipator 3B Cooling AnticipatorTesting Coil Circuit Checking Time Delay RelayChecking Transformer Control Circuit Checking Cycle ProtectorTesting FAN Relay Testing Compressor ContactorChecking Contactor AND/OR Relays Checking Contactor ContactsApplies to ASC13 & ASH13 Copeland Comfort Alert DiagnosticsRed Trip Diagnostics TableTesting Capacitor Resistance Hard Start KIT WiringChecking Loss of Charge Protector Checking Capacitor15B Capacitance Check Testing Capacitance16A Checking FAN and Blower Motor Windings PSC Motors 16B Checking FAN and Blower Motor ECM Motors16C Checking ECM Motor Windings 16D ECM CFM AdjustmentsChart on Next Chart from Previous Itc h Checking Compressor 16E Checking GE X13TM Motors17A Resistance Test GE X13TM Motor Connections17B Ground Test Testing Compressor Windings17D Operation Test Compressor Ground TestTesting Defrost Control Testing Crankcase Heater Optional ItemTesting Defrost Thermostat Checking Reversing Valve and SolenoidSequence of Operation 40 AR*F & MBR Electronic Blowers Time Delay RelayAR*F & MBR With Single Stage Condensers AR*F & MBR With Single Stage Heat Pumps41 AEP* & MBE with Single Stage CON Densers AEP* & MBE Electronic Blower Time Delay Relay41A AEP* & MBE with Single Stage Heat Pumps Electric Heater Optional Item 61A Checking Heater Limit Controls Temperature Rise F @ CFM61B Checking Heater Fuse Link Optional Electric Heaters Leak Testing Nitrogen or NITROGEN-TRACEDChecking Heater Elements Refrigeration Repair PracticeEvacuation EvacuationCharging An inaccurately charged system will cause future prob- lems Checking Compressor Efficiency105B Thermostatic Expansion Valve Underfeeding OverfeedingSuperheat Thermostatic Expansion ValvesChecking Expansion Valve Operation Checking SubcoolingChecking Restricted Liquid Line Overcharge of RefrigerantNON-CONDENSABLES Compressor BurnoutRefrigerant Piping Suction Line Drier Clean-Up MethodInstallation Requirements System Charging Reversing Valve ReplacementCoil Static Pressure Drop AIR Handler External StaticTotal External Static Static Pressure DropALL Fuel System Control Board AFE18-60A Accessories Wiring DiagramsALL Fuel System AFE18-60A Control Board 10kw and Below, One Stage Electric Heat OT/EHR18-60 #2 GRD PLM PLF XFMR-R XFMR-C After Installing Optional Heat KIT, Mark AN X Provided Above HKR Heat Kit GRD PLM PLF Accessories Wiring Diagrams