PRODUCT IDENTIFICATION

 

Single Piece Air Handlers

 

Model #

Description

 

 

 

 

 

 

A Single Piece E Multi-Position Variable-Speed Painted Flowrator. Introducation of

AEPF****16AA

new 13 SEER Air Handler Models. All Models will be suitable for use with R-22 and

 

R-410A

 

AEPF****16BA

A Single Piece E Multi-Position Variable-Speed Painted Flowrator. Revision

introduces new models adding lower kw hit kits on the S&R plate

 

 

 

 

 

AEPF****16BB

A Single Piece E Multi-Position Variable-Speed Painted Flowrator. Revision

replaces the current spot welded blower housing with the same cinched or crimped

 

design used on the 80% furnace line.

 

AEPF****16CA

A Single Piece E Multi-Position Variable-Speed Painted Flowrator. Revision

replaces all ARPFcoils using wavy fin with louver enhanced fin.

 

 

 

 

 

AEPF****1BA

A Single Piece E Multi-Position Variable-Speed Painted Flowrator Introduction of R-

22 Only Air Handlers.

 

 

 

 

 

AEPF313716AA

A Single Piece E Multi-Position Variable-Speed Painted Flowrator (AEPF) and A

Single Piece S Multi-Position EEM motor Painted Flowrator (ASPF). Introduction of

ASPF313716AA

3-Ton Air Handler units with 3-row coil.

 

 

 

 

 

ASPF****16AA

A Single Piece S Multi-Position EEM motor Painted Flowrator. Introduces new

ASPF Air Handlers

 

 

 

 

 

 

A Single Piece S Multi-Position EEM motor Painted Flowrator. Revision introuces

ASPF****16BA

modified ASPF control scheme, to ensure blower operation during and after call for

 

heat on units with heat kits and replacing wavy fin with louver enhanced fin on coil

 

 

 

AWUF****1AA

A Single Piece Air Handler Wall Mount Unpainted Flowrator. Introduces

13 SEER

Dayton wall mount air handlers

 

 

 

AWUF****16AA

A Single Piece Air Handler Wall Mount Unpainted Flowrator. Introduces

13 SEER

Dayton wall mount air handlers. All Models will be suitable for use with R-22 and R-

 

410A

 

AWUF3005-101AA

A Single Piece Air Handler Wall Mount Unpainted Flowrator. Introduces

13 SEER

Dayton wall mount air handlers using a Burr Oak Louvered Fin coil.

 

 

 

 

 

AWUF****1BA

A Single Piece Air Handler Wall Mount Unpainted Flowrator. Revision replaces

current wavey fin design with new louvered fin design

 

 

 

 

 

AWUF370**16AA

A Single Piece Air Handler Wall Mount Unpainted Flowrator. Introduction of

AWUF37 Air Handlers for use with R-22 and R410A.

 

 

 

AWUF****16BA

A Single Piece Air Handler Ceiling Mount N Uncased Flowrater. Revision has

 

 

 

 

louver fins & replaces copper tube hairpins with aluminum hairpins.

 

 

 

 

 

ACNF****1AA

A Single Piece Air Handler Ceiling Mount N Uncased Flowrater. Revision release

all models of 13 SEER Dayton uncased air handlers.

 

 

 

 

 

 

 

ACNF****16AA

A Single Piece Air Handler Ceiling Mount N Uncased Flowrater. Revision release

 

 

 

all models of 13 SEER Dayton uncased air handlers.All Models will be suitable for

 

use with R-22 and R-410A

 

ACNF****1BA

A Single Piece Air Handler Ceiling Mount N Uncased Flowrater. Revision replaces

 

 

 

 

current wavey fin design with new louvered fin design

 

 

 

 

 

AH**-1*

A Single Piece Air Handler Hydronic Air Handler. Revision replaces the time delay

relay in the AH air handlers with the UTEC time delay control board.

 

 

 

9

Image 9
Contents Service Instructions Important Information Table of ContentsSafe Refrigerant Handling Split System Air Conditioners R-22 Product IdentificationSplit System Air Conditioners R-22 Split System Heat Pumps R-22 Product Identification Single Piece Air Handlers Single Piece Air Handlers MBR/MBE Air Handlers 036 036 120 3642 1824 ASC01 AccessoriesCPKF24 CPKF36 CPKF42 CPKF48 CPKF60 CPKF61 Expansion Valve Kits FSK01A Coil Accessories Condensing Unit Product DesignProduct Design Heating System OperationCooling Cycle System Operation Indoor Coil Outdoor Thermostatic Expansion Valve Description AFE18-60A Control BoardCOOLING/HP Analysis Chart Troubleshooting ChartServicing Table of Contents Checking THERMOSTAT, WIRING, and Anticipator Checking Voltage Checking Wiring3A Thermostat and Wiring Servicing3C Heating Anticipator 3B Cooling AnticipatorTesting Coil Circuit Checking Time Delay RelayChecking Transformer Control Circuit Checking Cycle ProtectorTesting FAN Relay Testing Compressor ContactorChecking Contactor AND/OR Relays Checking Contactor ContactsApplies to ASC13 & ASH13 Copeland Comfort Alert DiagnosticsRed Trip Diagnostics TableTesting Capacitor Resistance Hard Start KIT WiringChecking Loss of Charge Protector Checking Capacitor15B Capacitance Check Testing Capacitance16A Checking FAN and Blower Motor Windings PSC Motors 16B Checking FAN and Blower Motor ECM Motors16C Checking ECM Motor Windings 16D ECM CFM AdjustmentsChart on Next Chart from Previous Itc h Checking Compressor 16E Checking GE X13TM Motors17A Resistance Test GE X13TM Motor Connections17B Ground Test Testing Compressor Windings17D Operation Test Compressor Ground TestTesting Defrost Control Testing Crankcase Heater Optional ItemTesting Defrost Thermostat Checking Reversing Valve and SolenoidSequence of Operation 40 AR*F & MBR Electronic Blowers Time Delay RelayAR*F & MBR With Single Stage Condensers AR*F & MBR With Single Stage Heat Pumps41 AEP* & MBE with Single Stage CON Densers AEP* & MBE Electronic Blower Time Delay Relay41A AEP* & MBE with Single Stage Heat Pumps Electric Heater Optional Item 61A Checking Heater Limit Controls Temperature Rise F @ CFM61B Checking Heater Fuse Link Optional Electric Heaters Leak Testing Nitrogen or NITROGEN-TRACEDChecking Heater Elements Refrigeration Repair PracticeEvacuation ChargingEvacuation An inaccurately charged system will cause future prob- lems Checking Compressor Efficiency105B Thermostatic Expansion Valve Underfeeding OverfeedingSuperheat Thermostatic Expansion ValvesChecking Expansion Valve Operation Checking SubcoolingChecking Restricted Liquid Line Overcharge of RefrigerantNON-CONDENSABLES Compressor BurnoutRefrigerant Piping Suction Line Drier Clean-Up MethodInstallation Requirements System Charging Reversing Valve ReplacementCoil Static Pressure Drop AIR Handler External StaticTotal External Static Static Pressure DropAccessories Wiring Diagrams ALL Fuel System AFE18-60A Control BoardALL Fuel System Control Board AFE18-60A 10kw and Below, One Stage Electric Heat OT/EHR18-60 #2 GRD PLM PLF XFMR-R XFMR-C After Installing Optional Heat KIT, Mark AN X Provided Above HKR Heat Kit GRD PLM PLF Accessories Wiring Diagrams