Goodman Mfg RT6100004R13 manual 120

Page 13

PRODUCT IDENTIFICATION

C

E

120

PRODUCT CATEGORY:

C: Split System

UNIT TYPE:

E:Commercial Air Conditioner

K:Air Cojditioner

P:Heat Pump

5

A

REVISION:

A: Revision

ELECTRICAL:

1:208-230V/1ph/60Hz

2:220-240V/1ph/50 Hz

3:208-230v/3ph/60Hz

4:308/415V/3ph/50Hz

 

NOMINAL CAPACITY:

 

018: 1.5 Tons

048:

4

Tons

024:

2

Tons

060:

5

Tons

030: 2.5

Tons

070:

5

Tons

036:

3

Tons

090: 7.5 Tons

042: 3.5

Tons

120:

10

Tons

 

 

 

 

 

 

THIS NOMENCLATURE IS TO BE USED TRHOUGH JULY 2006

 

A

R U

F

 

 

 

 

 

 

Product Type

A: Single Piece Air Handler

Application

C:Ceiling Mount PSC Motor

D:Downflow PSC Motor

E:Multi-Position Variable Speed Motor

R:Multi-Position PSC Motor

W:Wall Mount PSC Motor

Cabinet Finish

U: Unpainted

P: Painted

N: Uncased

Expansion Device

F: Flowrater

3642

1

A

A

 

 

 

 

 

Minor Revision

A: Initial Release

Major Revision

A: Initial Release

Electrical

1: 208/230V, 1 Phase, 60 Hz

Nominal Capacity Range @ 13 SEER

Multi-Position & Downflow Applications 3642: 3 - 3 1/2 tons

1830: 1 1/2 - 3 1/2 tons

1729: 1 1/2 - 2 1/2 Tons 10 SEER (for export systems) Ceiling Mount & Wall Mount Applications

1805: Nominal Cooling Capacity

Electric Heat kw - 1 1/2 tons Cooling/5 kw Electric Heat 2405: Nominal Cooling Capacity

Electric Heat kw - 2 Tons Cooling/5 kw Electric Heat 3608: Nominal Cooling Capacity

Electric Heat kw - 3 Tons Cooling/8 kw Electric Heat

13

Image 13
Contents Service Instructions Important Information Table of ContentsSafe Refrigerant Handling Split System Air Conditioners R-22 Product IdentificationSplit System Air Conditioners R-22 Split System Heat Pumps R-22 Product Identification Single Piece Air Handlers Single Piece Air Handlers MBR/MBE Air Handlers 036 036 120 3642 1824 ASC01 AccessoriesCPKF24 CPKF36 CPKF42 CPKF48 CPKF60 CPKF61 Expansion Valve Kits FSK01A Coil Accessories Condensing Unit Product DesignProduct Design Heating System OperationCooling Cycle System Operation Indoor Coil Outdoor Thermostatic Expansion Valve Description AFE18-60A Control BoardCOOLING/HP Analysis Chart Troubleshooting ChartServicing Table of Contents Checking THERMOSTAT, WIRING, and Anticipator Checking Voltage Checking Wiring3A Thermostat and Wiring Servicing3C Heating Anticipator 3B Cooling AnticipatorTesting Coil Circuit Checking Time Delay RelayChecking Transformer Control Circuit Checking Cycle ProtectorTesting FAN Relay Testing Compressor ContactorChecking Contactor AND/OR Relays Checking Contactor ContactsApplies to ASC13 & ASH13 Copeland Comfort Alert DiagnosticsRed Trip Diagnostics TableTesting Capacitor Resistance Hard Start KIT WiringChecking Loss of Charge Protector Checking Capacitor15B Capacitance Check Testing Capacitance16A Checking FAN and Blower Motor Windings PSC Motors 16B Checking FAN and Blower Motor ECM Motors16C Checking ECM Motor Windings 16D ECM CFM AdjustmentsChart on Next Chart from Previous Itc h Checking Compressor 16E Checking GE X13TM Motors17A Resistance Test GE X13TM Motor Connections17B Ground Test Testing Compressor Windings17D Operation Test Compressor Ground TestTesting Defrost Control Testing Crankcase Heater Optional ItemTesting Defrost Thermostat Checking Reversing Valve and SolenoidSequence of Operation 40 AR*F & MBR Electronic Blowers Time Delay RelayAR*F & MBR With Single Stage Condensers AR*F & MBR With Single Stage Heat Pumps41 AEP* & MBE with Single Stage CON Densers AEP* & MBE Electronic Blower Time Delay Relay41A AEP* & MBE with Single Stage Heat Pumps Electric Heater Optional Item 61A Checking Heater Limit Controls Temperature Rise F @ CFM61B Checking Heater Fuse Link Optional Electric Heaters Leak Testing Nitrogen or NITROGEN-TRACEDChecking Heater Elements Refrigeration Repair PracticeCharging EvacuationEvacuation An inaccurately charged system will cause future prob- lems Checking Compressor Efficiency105B Thermostatic Expansion Valve Underfeeding OverfeedingSuperheat Thermostatic Expansion ValvesChecking Expansion Valve Operation Checking SubcoolingChecking Restricted Liquid Line Overcharge of RefrigerantNON-CONDENSABLES Compressor BurnoutRefrigerant Piping Suction Line Drier Clean-Up MethodInstallation Requirements System Charging Reversing Valve ReplacementCoil Static Pressure Drop AIR Handler External StaticTotal External Static Static Pressure DropALL Fuel System AFE18-60A Control Board Accessories Wiring DiagramsALL Fuel System Control Board AFE18-60A 10kw and Below, One Stage Electric Heat OT/EHR18-60 #2 GRD PLM PLF XFMR-R XFMR-C After Installing Optional Heat KIT, Mark AN X Provided Above HKR Heat Kit GRD PLM PLF Accessories Wiring Diagrams