Goodman Mfg RT6100004R13 manual 036

Page 12

PRODUCT IDENTIFICATION

C

KF

036

PRODUCT CATEGORY:

C: Split System

UNIT TYPE:

E:Commercial Air Conditioner

K:Air Cojditioner

P:Heat Pump

2

A

REVISION:

A: Revision

ELECTRICAL:

1:208-230V/1ph/60Hz

2:220-240V/1ph/50 Hz

3:208-230v/3ph/60Hz

4:308/415V/3ph/50Hz

 

 

NOMINAL CAPACITY:

 

 

 

018: 1.5 Tons

048:

4

Tons

 

 

024:

2

Tons

060:

5

Tons

 

 

030: 2.5

Tons

070:

5

Tons

 

 

036:

3

Tons

090: 7.5 Tons

 

 

042: 3.5

Tons

120:

10 Tons

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

KL

PRODUCT CATEGORY:

C: Split System

UNIT TYPE:

E:Commercial Air Conditioner

K:Air Cojditioner

P:Heat Pump

036

2

A

REVISION:

A: Revision

ELECTRICAL:

1:208-230V/1ph/60Hz

2:220-240V/1ph/50 Hz

3:208-230v/3ph/60Hz

4:308/415V/3ph/50Hz

 

NOMINAL CAPACITY:

 

018: 1.5 Tons

048:

4

Tons

024:

2

Tons

060:

5

Tons

030: 2.5

Tons

070:

5

Tons

036:

3

Tons

090: 7.5 Tons

042: 3.5

Tons

120:

10

Tons

 

 

 

 

 

 

12

Image 12
Contents Service Instructions Table of Contents Important InformationSafe Refrigerant Handling Product Identification Split System Air Conditioners R-22Split System Air Conditioners R-22 Split System Heat Pumps R-22 Product Identification Single Piece Air Handlers Single Piece Air Handlers MBR/MBE Air Handlers 036 036 120 3642 1824 Accessories ASC01CPKF24 CPKF36 CPKF42 CPKF48 CPKF60 CPKF61 Expansion Valve Kits FSK01A Coil Accessories Product Design Condensing UnitProduct Design System Operation HeatingCooling Cycle System Operation Indoor Coil Outdoor Thermostatic Expansion Valve AFE18-60A Control Board DescriptionTroubleshooting Chart COOLING/HP Analysis ChartServicing Table of Contents Checking Voltage Checking Wiring Checking THERMOSTAT, WIRING, and Anticipator3A Thermostat and Wiring Servicing3B Cooling Anticipator 3C Heating AnticipatorChecking Time Delay Relay Testing Coil CircuitChecking Transformer Control Circuit Checking Cycle ProtectorTesting Compressor Contactor Testing FAN RelayChecking Contactor AND/OR Relays Checking Contactor ContactsCopeland Comfort Alert Diagnostics Applies to ASC13 & ASH13Diagnostics Table Red TripHard Start KIT Wiring Testing Capacitor ResistanceChecking Loss of Charge Protector Checking CapacitorTesting Capacitance 15B Capacitance Check16A Checking FAN and Blower Motor Windings PSC Motors 16B Checking FAN and Blower Motor ECM Motors16D ECM CFM Adjustments 16C Checking ECM Motor WindingsChart on Next Chart from Previous Itc h 16E Checking GE X13TM Motors Checking Compressor17A Resistance Test GE X13TM Motor ConnectionsTesting Compressor Windings 17B Ground Test17D Operation Test Compressor Ground TestTesting Crankcase Heater Optional Item Testing Defrost ControlTesting Defrost Thermostat Checking Reversing Valve and Solenoid40 AR*F & MBR Electronic Blowers Time Delay Relay Sequence of OperationAR*F & MBR With Single Stage Condensers AR*F & MBR With Single Stage Heat PumpsAEP* & MBE Electronic Blower Time Delay Relay 41 AEP* & MBE with Single Stage CON Densers41A AEP* & MBE with Single Stage Heat Pumps Electric Heater Optional Item Temperature Rise F @ CFM 61A Checking Heater Limit ControlsLeak Testing Nitrogen or NITROGEN-TRACED 61B Checking Heater Fuse Link Optional Electric HeatersChecking Heater Elements Refrigeration Repair PracticeEvacuation ChargingEvacuation Checking Compressor Efficiency An inaccurately charged system will cause future prob- lems105B Thermostatic Expansion Valve Overfeeding UnderfeedingSuperheat Thermostatic Expansion ValvesChecking Subcooling Checking Expansion Valve OperationOvercharge of Refrigerant Checking Restricted Liquid LineNON-CONDENSABLES Compressor BurnoutSuction Line Drier Clean-Up Method Refrigerant PipingInstallation Requirements Reversing Valve Replacement System ChargingAIR Handler External Static Coil Static Pressure DropTotal External Static Static Pressure DropAccessories Wiring Diagrams ALL Fuel System AFE18-60A Control BoardALL Fuel System Control Board AFE18-60A 10kw and Below, One Stage Electric Heat OT/EHR18-60 #2 GRD PLM PLF XFMR-R XFMR-C After Installing Optional Heat KIT, Mark AN X Provided Above HKR Heat Kit GRD PLM PLF Accessories Wiring Diagrams