PRODUCT IDENTIFICATION

 

MBR/MBE Air Handlers

Model #

Description

 

 

MBR****AA-1AA

Modular Blower R Multi-Position PSC Motor. Introduces module blower with PSC

blower motor.

 

 

 

MBE****AA-1AA

Modular Blower E Multi-Position Variable-Speed. Introduces module blower with

variable speed blower motor.

 

 

 

MBE****AA-1BA

Modular Blower E Multi-Position Variable-Speed.Revision introduces new models

adding lower kw hit kits on the S&R plate

 

 

 

 

 

 

Evaporator Coils

Model #

 

 

Description

 

 

 

 

CAUF*****6AA

C Indoor Coil A Upflow/Downflow Uncased Flowrator. Introduces 13 SEER CAUF

 

 

 

Dayton Upflow/Downflow coils.

 

 

 

CAUF*****6BA

C Indoor Coil A Upflow/Downflow Uncased Flowrator. Revision releases Burr Oak

 

 

 

Louvered Fin in place of the Wavy Fin currently in production.

 

 

 

CAPF*****6AA

C Indoor Coil A Upflow/Downflow Painted Flowrator. Introduces 13 SEER CAPF

 

 

 

Dayton Upflow/Downflow coils.

 

 

 

CAPF*****6BA

C Indoor Coil A Upflow/Downflow Painted Flowrator. Revision releases Burr Oak

 

 

 

Louvered Fin in place of the Wavy Fin currently in production.

 

 

 

CAPF/CAUF36***CA

C Indoor Coil A Upflow/Downflow [Painted or Uncased] Flowrator. Revision

 

 

 

redesigns for performance improvement from 2 row to 3 row.

 

 

 

CHPF*****6AA

C Indoor Coil Horizontal A Coil Painted Flowrator. Release 13 SEER CHPF

horizontal A coil.

 

 

 

 

C Indoor Coil Horizontal A Coil Painted Flowrator. Release 13 SEER CHPF

CHPF*****6BA

horizontal A coil. Revision releases Burr Oak Louvered Fin in place of the Wavy

Fin currently in production. The rows change by one, (i.e. 4 row to 3 row; 3 row to

 

 

2 row) where applicable.

 

 

 

 

CHPF1824A6CA

 

 

 

CHPF2430B6CA

 

 

 

CHPF3636B6CA

C Indoor Coil Horizontal A Coil Painted Flowrator. 13 SEER CHPF horizontal A

CHPF3642C6CA

coil, revision has louver fins & replaces copper tube hairpins with aluminum

CHPF3642D6CA

hairpins.

CHPF3743C6BA

 

 

 

CHPF3743D6BA

 

 

 

CHPF4860D6DA

 

 

 

CSCF*****6AA

C Indoor Coil S Horizontal Slab Coil C Upainted Flowrator. Release 13 SEER

CSCF slab horizontal coil.

 

 

 

 

C Indoor Coil S Horizontal Slab Coil C Upainted Flowrator. Revision releases Burr

CSCF*****6BA

Oak Louvered Fin in place of the Wavy Fin currently in production. The rows

 

change by one, (i.e. 4 row to 3 row; 3 row to 2 row) where applicable.

 

 

 

 

10

Image 10
Contents Service Instructions Table of Contents Important InformationSafe Refrigerant Handling Product Identification Split System Air Conditioners R-22Split System Air Conditioners R-22 Split System Heat Pumps R-22 Product Identification Single Piece Air Handlers Single Piece Air Handlers MBR/MBE Air Handlers 036 036 120 3642 1824 Accessories ASC01CPKF24 CPKF36 CPKF42 CPKF48 CPKF60 CPKF61 Expansion Valve Kits FSK01A Coil Accessories Product Design Condensing UnitProduct Design System Operation HeatingCooling Cycle System Operation Indoor Coil Outdoor Thermostatic Expansion Valve AFE18-60A Control Board DescriptionTroubleshooting Chart COOLING/HP Analysis ChartServicing Table of Contents 3A Thermostat and Wiring Checking Voltage Checking WiringChecking THERMOSTAT, WIRING, and Anticipator Servicing3B Cooling Anticipator 3C Heating AnticipatorChecking Transformer Control Circuit Checking Time Delay RelayTesting Coil Circuit Checking Cycle ProtectorChecking Contactor AND/OR Relays Testing Compressor ContactorTesting FAN Relay Checking Contactor ContactsCopeland Comfort Alert Diagnostics Applies to ASC13 & ASH13Diagnostics Table Red TripChecking Loss of Charge Protector Hard Start KIT WiringTesting Capacitor Resistance Checking Capacitor16A Checking FAN and Blower Motor Windings PSC Motors Testing Capacitance15B Capacitance Check 16B Checking FAN and Blower Motor ECM Motors16D ECM CFM Adjustments 16C Checking ECM Motor WindingsChart on Next Chart from Previous Itc h 17A Resistance Test 16E Checking GE X13TM MotorsChecking Compressor GE X13TM Motor Connections17D Operation Test Testing Compressor Windings17B Ground Test Compressor Ground TestTesting Defrost Thermostat Testing Crankcase Heater Optional ItemTesting Defrost Control Checking Reversing Valve and SolenoidAR*F & MBR With Single Stage Condensers 40 AR*F & MBR Electronic Blowers Time Delay RelaySequence of Operation AR*F & MBR With Single Stage Heat PumpsAEP* & MBE Electronic Blower Time Delay Relay 41 AEP* & MBE with Single Stage CON Densers41A AEP* & MBE with Single Stage Heat Pumps Electric Heater Optional Item Temperature Rise F @ CFM 61A Checking Heater Limit ControlsChecking Heater Elements Leak Testing Nitrogen or NITROGEN-TRACED61B Checking Heater Fuse Link Optional Electric Heaters Refrigeration Repair PracticeCharging EvacuationEvacuation Checking Compressor Efficiency An inaccurately charged system will cause future prob- lems105B Thermostatic Expansion Valve Superheat OverfeedingUnderfeeding Thermostatic Expansion ValvesChecking Subcooling Checking Expansion Valve OperationNON-CONDENSABLES Overcharge of RefrigerantChecking Restricted Liquid Line Compressor BurnoutSuction Line Drier Clean-Up Method Refrigerant PipingInstallation Requirements Reversing Valve Replacement System ChargingTotal External Static AIR Handler External StaticCoil Static Pressure Drop Static Pressure DropALL Fuel System AFE18-60A Control Board Accessories Wiring DiagramsALL Fuel System Control Board AFE18-60A 10kw and Below, One Stage Electric Heat OT/EHR18-60 #2 GRD PLM PLF XFMR-R XFMR-C After Installing Optional Heat KIT, Mark AN X Provided Above HKR Heat Kit GRD PLM PLF Accessories Wiring Diagrams