Ericsson LBI-38823D manual Removing the Battery Pack, Charging the Battery Packs

Page 20

REMOVING THE BATTERY PACK

1.Ensure the ON/OFF switch on the battery pack is in the off position.

2.Press down on the battery release latch and slide the battery pack out in the direction of the release latch. See Figure 8.

CHARGING THE BATTERY PACKS

New batteries or batteries that have been stored for a long period of time, should be fully charged before placing into service. When the battery pack requires charging the "BT" indicator in the LCD will turn on and the radio will sound a low pitch tone every 130 seconds.

Rechargeable batteries in some applications can develop a condition of reduced capacity, sometimes called "Memory Effect". This condition may occur when:

1.The battery is continuously overcharged for long periods of time.

2.A regularly performed duty cycle allows the battery to expend only a limited portion of its capacity.

If the rechargeable battery is only sparingly or seldom used and is left on continuous charge for one or two months at a time, it could experience reduced capacity. This would severely reduce the life of the battery between charges.

The most common method of producing this limited capacity is regu- larly performing short duty cycles; when the battery is operated so that only a portion (<50%) of its capacity is expended. This type of operation can cause the battery to become temporarily inactive and show severe decrease in the ability to deliver at full rated capacity.

Any rechargeable battery showing signs of reduced capacity, should be taken to a qualified Service Technician to be carefully checked before being returned under warranty or scrapped.

20

Image 20
Contents Ericssonz Page Table of Contents Keypad Lock System Model Only Dynamic Regrouping OptionalEmergency Operation Optional Introduction Dual Format PCS Radio Scan Model Dual Format PCS Radio System Model Switch DescriptionControls ON/OFF PTT ButtonScan Model Keypad HOME/E SPCSCAN-A/D STOIndicators LockAvailable on System Model radios only RCLBSY System And Group/Channel IndicatorsStatus Indicators SCN Radio is in the Program modeTurn on Standard Tones Power-Up Low BatteryCarrier Control Timer Alert TonesCall Received Call Queued Edacs OnlyAutokey Edacs Only System BusyIntrinsically Safe Usage Error MessagesOut Of Range/System Inoperative Pictured on Options and Accessories Option # Description Options And Accessories Installing the Battery Pack Battery PacksBattery Packs FM Approved Removing the Battery Pack Charging the Battery PacksInstalling the Battery Pack Rechargeable Battery Pack Disposal Swivel Mount Removal and ReplacementSwivel Mount Removal And Replacement Operating Tips Operating ProceduresWhen using two-way radios, remember the following rules Page NICKEL-CADMIUM Battery Warranty Receiving a Message Current System selectedSending a Message Using the Volume buttons, adjust the volume as necessarySquelch Adjustment Scan Model Radio Press and hold the SHFT/CLR buttonSending a Special Call System Model Radio Sending a Manually Entered Individual CallPage Sending a Manually Entered Interconnect Call Storing Individual And Interconnect Numbers Enter the desired storage location number Edacs Special Call Flowchart Enable/Disable Scan Scan OperationAdd/Delete Groups Wide Area And Priority System Scanning OptionalDtmf Overdial ProSoundDynamic Regrouping Optional To enable an Emergency transmission Pressing the PTT bar to send the tonesHOME/EMERGENCY KEY Definition Emergency Operation Optional Receiving An Emergency CallHome Keypad Lock System Model OnlyPage GE-MARC Operation Sending a Message Sending a Special Call Sending a Preprogrammed Special Call In Conference Call Sending a Manually Entered Individual Call Sending a Manually Entered Interconnect Call Page Storing Individual And Interconnect Numbers Page Number will be displayed GE-MARC Special Call Flowchart Receiving a Message Direct ModeWide Area System Scan Sending a Message Sending a Manually Entered Interconnect Call Add/Delete ChannelsScan must be disabled to add a channel to the scan list To delete Channels from the scan listThis page intentionally left blank Conventional Mode Operation Sending a Message After all the digits have been keyed in, release the PTT bar Page Frequency Band OPERATOR’S Name Emergency Group System System Number Name TRK/CNV GRP/CHN GRP/CHN USE Warranty Emergency Numbers