Ericsson LBI-38823D manual Enter the desired storage location number

Page 34

5.Press the STO key (shifted *) to complete the storage procedure.

6.Double click the SHIFT/CLR button to exit the Special Call mode and return to the normal System/Group display.

Recalling Manually Stored Individual And Interconnect Numbers

1.Press the # key to recall the individual call list or the * key to specify the interconnect call list. The screen will blank and a tone will sound.

2.Enter the desired storage location number (0-9).

3.Press the RCL (shifted #) key and the radio will switch to the Special Call mode. If the number is from the individual call list the ID number will be displayed. If the number is from the interconnect call list, the last four digits of the telephone number will be displayed.

If the memory location is blank the radio will sound a low pitch tone after the RCL is pressed.

4.Individual - Once the desired individual call number is displayed in the GRP (Group) field, press and hold the PTT to initiate the call. The radio performs the necessary signalling required to obtain a working chan- nel.

Interconnect - Once the desired interconnect special call number is displayed in the GRP (Group) field, press and release thePTT to initiate the call. The radio performs the necessary signalling required to obtain a working channel.

5.Individual - When the signalling is successfully completed the "TX" and "BSY" flags turn on and the Call Originate tone sounds. Speak directly into the microphone. Release the PTT bar as soon as you stop talking and wait for a reply.

34

Image 34
Contents Ericssonz Page Table of Contents Emergency Operation Optional Dynamic Regrouping OptionalKeypad Lock System Model Only Introduction Dual Format PCS Radio Scan Model Dual Format PCS Radio System Model Controls ON/OFF SwitchDescription PTT ButtonScan Model Keypad SCAN-A/D HOME/ESPC STOAvailable on System Model radios only IndicatorsLock RCLStatus Indicators System And Group/Channel IndicatorsBSY Turn on Radio is in the Program modeSCN Carrier Control Timer Standard Tones Power-UpLow Battery Alert TonesAutokey Edacs Only Call ReceivedCall Queued Edacs Only System BusyOut Of Range/System Inoperative Error MessagesIntrinsically Safe Usage Option # Description Options and AccessoriesPictured on Options And Accessories Battery Packs FM Approved Battery PacksInstalling the Battery Pack Removing the Battery Pack Charging the Battery PacksInstalling the Battery Pack Rechargeable Battery Pack Disposal Swivel Mount Removal and ReplacementSwivel Mount Removal And Replacement When using two-way radios, remember the following rules Operating ProceduresOperating Tips Page NICKEL-CADMIUM Battery Warranty Receiving a Message Current System selectedSquelch Adjustment Using the Volume buttons, adjust the volume as necessarySending a Message Sending a Special Call Press and hold the SHFT/CLR buttonScan Model Radio System Model Radio Sending a Manually Entered Individual CallPage Sending a Manually Entered Interconnect Call Storing Individual And Interconnect Numbers Enter the desired storage location number Edacs Special Call Flowchart Add/Delete Groups Enable/Disable ScanScan Operation Wide Area And Priority System Scanning OptionalDynamic Regrouping Optional ProSoundDtmf Overdial HOME/EMERGENCY KEY Definition To enable an Emergency transmissionPressing the PTT bar to send the tones Emergency Operation Optional Receiving An Emergency CallHome Keypad Lock System Model OnlyPage GE-MARC Operation Sending a Message Sending a Special Call Sending a Preprogrammed Special Call In Conference Call Sending a Manually Entered Individual Call Sending a Manually Entered Interconnect Call Page Storing Individual And Interconnect Numbers Page Number will be displayed GE-MARC Special Call Flowchart Wide Area System Scan Direct ModeReceiving a Message Sending a Message Sending a Manually Entered Interconnect Call Add/Delete ChannelsScan must be disabled to add a channel to the scan list To delete Channels from the scan listThis page intentionally left blank Conventional Mode Operation Sending a Message After all the digits have been keyed in, release the PTT bar Page Frequency Band OPERATOR’S Name Emergency Group System System Number Name TRK/CNV GRP/CHN GRP/CHN USE Warranty Emergency Numbers

LBI-38823D specifications

The Ericsson LBI-38823D is a significant component in the realm of telecommunications technology, reflecting the advancement in infrastructure aimed at enhancing mobile network performance. As part of Ericsson's extensive portfolio, this product is designed to support various network requirements and enable operators to optimize their services effectively.

One of the primary features of the LBI-38823D is its compatibility with LTE networks, providing seamless integration for operators looking to enhance their existing infrastructures. The unit is engineered to facilitate high-speed data transmission while ensuring low latency, which is crucial for applications requiring real-time performance such as video streaming and online gaming.

In terms of technology, the LBI-38823D supports advanced functionalities like MIMO (Multiple Input Multiple Output), which significantly boosts data throughput and signal quality. MIMO technology utilizes multiple antennas at the transmitter and receiver ends, enabling the simultaneous transmission of multiple data streams. This results in an increase in capacity and reliability, which are essential for meeting the demands of a growing user base and the rising expectations for mobile services.

Another noteworthy characteristic is its support for Carrier Aggregation, a technique that combines different frequency bands to enhance network efficiency and user experience. By aggregating carriers, the Ericsson LBI-38823D enables operators to maximize their spectrum usage, leading to improved peak data rates and overall network performance.

Moreover, the LBI-38823D is built with robust security features, ensuring that data transmission remains secure against potential breaches. As cybersecurity becomes increasingly critical in telecommunications, this product has been designed to protect both operator networks and end-user information.

Designed for scalability, the LBI-38823D allows operators to expand their networks easily as demand grows. This flexibility makes it an ideal choice for service providers looking to future-proof their investments and ensure long-term viability.

Overall, the Ericsson LBI-38823D is a state-of-the-art solution that embodies the convergence of innovation and reliability in telecommunications. With its advanced features, support for cutting-edge technologies, and emphasis on security and scalability, it is well-positioned to meet the evolving needs of the telecommunications industry while enhancing user experience.