Friedrich SH15, SH20 operation manual Filter Information, Maintenance Checklist

Page 4

920-024-05 (12-04)

Filter Information

The filter in your Friedrich removes dust, pollen and other impurities from the air as they are drawn through the unit. The filter is permanent and reusable, and has a germicidal treatment which is not affected by washing.

A clogged, dirty filter reduces the air flow through the unit and reduces its efficiency. You should check the filter every seven to ten days, depending on the amount your unit is used. Clean the filter regularly.

FILTER RETAINER CLIPS

The fi lter can be removed for cleaning by opening the front of

the unit and releasing the fi lter from its retaining clips.

Maintenance Checklist

Won’t Cool

If the unit operates, but doesn’t cool, check to see that the con- trols are properly set. Inspect the filter and clean it thoroughly, if needed. Check to see if the chassis seal gasket is installed (refer to installation instructions).

coil should ice over while cooling, set the thermostat to the warm- est position until the ice on the coil is gone. Setting the thermostat to a slightly warmer position will probably keep ice from forming on the coil. A dirty filter will contribute to icing.

Won’t Run

If the unit does not operate at all, check that the power supply connections are tight. Check for blown fuses or tripped circuit breakers. Replace blown fuses with the proper size time-delay fuse. The nameplate on the unit shows the proper fuse size. After restoring power, wait three minutes before restarting the unit.

Inside Coil Freezes Up

Your Friedrich Hazardgard is designed not to freeze with outdoor temperatures as low as 45°F (7°C). Freezing should only occur when the outside air is damp and below 45°F (7°C). If the indoor

Cleaning

The front grille of your Friedrich, as well as the complete cabi- net may be cleaned with warm water and a mild detergent. The coils and base pan should be cleaned periodically for the most efficient operation. We suggest you call your Friedrich dealer for this service.

Lubrication

Fan motors are factory lubricated and sealed. No lubrication is required.

4

Image 4
Contents Hazardous Duty Room Air Conditioner Volt SH15 SH20Table of Contents Clean the filter frequently See General Maintenance Maintenance Checklist Filter InformationHazardgard Special Features Function Control PowerTemperature Control Control PanelModels SH15 and SH20 Electrical Requirements GroupsHazardgard Window Mount Installation Hardware Accessory DetailUnpacking The Unit Chassis Wiring and PreparationProvided Hardware Shell Cabinet Preparation BeforeShell Installation Sash Window Installations Shell Cabinet Installation Standard Sash WindowsTypical Installation Sill Plate Section a a Section B BShell Installation Through-the-wall Installations Wall PreparationSpecial Instructions For Extra Thick Walls Hole Size RequirementsBrick Veneer Construction Frame Wall ConstructionSolid Masonry Typical Installation Screw #12A X 2 LongChassis Installation StepDetail Hazardgard Room AIR Conditioners Limited Warranty Instrucciones de Instalacion y Funcionamiento Instrucciones Para Uso Y Mantenimiento Tabla De ContenidosInstrucciones Para La Instalacion Instrucciones Generales Informacion Sobre El Filtro Lista De Control Para El MantenimientoCaracteristicas Especiales Del Hazardgard Panel De ControlControl De Encendido Electricidad Control De La Temperatura¡Exclusiva Requerimientos Electricos Modelos SH15 y SH20Grupos Tamaño DEL Gabinete Lista DE Accesorios Número Descripción Cantidad De itemPreparacion y Instalacion Electrica Del Chasis Desempaque de la unidadHerramienta QUE SE Suministra Si la instalacion se hace a traves de la pared AntesdespuesFigura D Instalacion Tipica Del Filo Del Antepecho Figura G Dimension Chasis Terminada Pequeño Mediano Nota Estas SON LAS Dimensiones DEL Hueco TerminadoPreparacion De La Pared Instrucciones Especiales Para Paredes Extra GruesasConstruccion EN EL Marco DE LA ParedConstruccion EN Paredes DE LadrilloInstalacion Tipica Instalacion Del Chasis PasoFigura Q DetallePage Instructions d’installation et d’utilisation Instructions D’installation Table Des Matières920-024-05 Dépannage Panneau De Commande Commande De Fonction Mise En MarcheCommande De Température Caractéristiques Spéciales Des Appareils HazardgardExclusivité Alimentation Électrique Modèles SH 15 et SHGroupes Détail DES Accessoires Branchement Du Châssis Et Préparation Déballage De L’appareilQuincaillerie Fournie Installation dans une fenêtre à guillotine Installation à travers un murPréparation De L’enveloppe Avant AprèsInstallation de l’enveloppe fenêtre à guillotine standard Patte DE Support RÉFInstallation Typique De La Plaque De Seuil Coupe B B Dimensions Finies DE L’OUVERTURE Installation De Lenveloppe Installation À Travers Un MurPréparation Du Mur Construction Avec UN Cadre EN Bois Construction AvecInstallation Typique Boulon DE ScellementInstallation Du Châssis Détail Garantie Limite DUN AN Climatiseurs Hazardgard Friedrich
Related manuals
Manual 60 pages 10.39 Kb Manual 60 pages 9.21 Kb

SH20, SH15 specifications

The Friedrich SH15 and SH20 models are exemplary representatives of advanced heating solutions, designed to address the diverse needs in residential and commercial environments. Engineered with a focus on efficiency, performance, and user-friendliness, these heating systems make a strong case for modern heating technology.

One of the standout features of both the SH15 and SH20 is their energy efficiency. These models utilize state-of-the-art heat pump technology, which allows them to extract heat from the environment even in colder temperatures. This results in significantly lower energy consumption compared to traditional heating systems, leading to reduced utility bills and a lower carbon footprint. The SH15 is designed for smaller spaces, while the SH20 offers a bit more power, making it suitable for larger areas or homes with greater heating demands.

Both models incorporate advanced inverter technology, which adjusts the compressor speed depending on the heating requirements. This ensures that the units operate at optimal efficiency, providing consistent temperature control while minimizing energy waste. Inverter-driven systems contribute to quieter operation as well, which is ideal for residential settings where noise can be a concern.

User-friendliness is another hallmark of the Friedrich SH15 and SH20. Equipped with intuitive digital controls, users can easily set their preferred temperatures and schedules, allowing for personalized comfort. Moreover, both models support smart home integration, enabling remote access and control through mobile applications. This feature not only enhances convenience but also allows users to monitor energy usage and make adjustments on the fly.

Durability is a key characteristic of these heating systems. Constructed with high-quality materials, the SH15 and SH20 are designed to withstand harsh environmental conditions, ensuring long-lasting performance. They also feature advanced air filtration systems that improve indoor air quality by effectively removing allergens and other pollutants.

In summary, the Friedrich SH15 and SH20 embody the cutting-edge of heating technology, offering powerful, efficient, and user-friendly solutions for diverse heating needs. With their advanced features, smart technology integration, and robust construction, these models are well-suited for modern living, ensuring comfortable and environmentally responsible heating year-round.