F-60

TROUBLESHOOTING & REPAIR

F-60

 

 

 

RETEST AFTER REPAIR

Retest a machine:

If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics.

OR

• If you repair or replace any electrical components.

ENGINE OUTPUT

Mode

No Load RPM

Load RPM

Low Idle

2150-2250

NA

High Idle

3700-3750

3100-3600

WELDER DC OUTPUT1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

 

 

 

Volts

 

 

 

Maximum

Maximum

65 - 72

21 - 26.5

205 - 240

 

 

 

 

 

 

 

WELDER AC OUTPUT1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

 

 

 

Volts

 

 

 

Maximum

Maximum

73 - 80

25 - 32

225 - 275

 

 

 

 

 

 

 

WELDER CV OUTPUT1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

 

 

 

Volts

 

 

 

Maximum

Wire Feed CV

29 - 33

19 - 22

200 - 220

 

 

 

 

 

 

 

AUXILIARY POWER RECEPTACLE OUTPUT1

 

230 Volt Receptacle

 

 

115 Volt Receptacle2

 

 

Open Circuit

Load Volts

 

Load Amps

Open Circuit

 

Load Volts

 

Load Amps

 

Voltage

 

 

 

Voltage

 

 

 

 

 

246 - 264

216 - 250

 

34 - 41.5

123- 132

 

114 - 126

 

35 - 42

 

 

FIELD AMPS AND VOLTS

 

 

 

 

 

Slip Ring Volts

 

Field Amps

 

28.0 - 46.0 VDC

 

6.5 - 7.5 VDC

 

 

 

 

 

1OUTPUT CONTROL switch set at MAXIMUM (position 10).

2Output values of each receptacle can vary within the range shown but must be within 2 volts of each other.

RANGER® 10,000 & RANGER® 10,000 PLUS

Image 100
Contents Ranger 10,000 /10,000 Plus Powered equipment SafetyFor Engine ARC Rays can burn Fumes and GasesCylinder may explode If damaged Welding and Cutting Sparks can cause fire or ExplosionIii Précautions DE Sûreté Master Table of Contents for ALL Sections Installation Section Table of ContentsSection A-1 Installation Height Width Depth WeightHorsepower Operating Speed RPM Safety Precautions Spark ArresterMachine Grounding TowingPRE-OPERATION Service GasolineVehicle Mounting Can cause fire or explosionWelding Output Cables Total Combined Length of Electrode and Work CablesAngle of Operation LiftingConnection of Lincoln Electric Wire Feeders InstructionsStacking Welder OperationAuxiliary Power 120/240 Volt Dual Voltage ReceptacleDuplex Receptacles Motor StartingThese Devices Without Additional Resistive Type Loads Not USE These Devices With a Ranger 10,000Simultaneous Welding and Power Standby Power ConnectionsFigure A.1 Ranger 10,000 & Ranger 10,000 Plus Section B-1 Operation SectionOperation Operation Engine SwitchWelder Controls Function and Operation Polarity Switch Range SwitchKohler Honda Robin / Subaru 20 H.P. Command Control DialSTARTING/SHUTDOWN Instructions BREAK-IN PeriodStarting the Engine Stopping the EngineStick Constant Current Welding Wire Feed Welding Processes Constant VoltageTIG Constant Current Welding Start Switch Wire FEED, LN-15 Summary of Welding ProcessesAccessories Section Section C-1Accessories Optional Equipment Field InstalledRecommended Equipment StickTIG Welding Plasma CuttingRanger 10,000 & Ranger 10,000 Plus Maintenance Section Section D-1Safety Precautions MaintenanceKohler Honda AIR Cleaner and Other Maintenance OIL Filter ChangeEngine Adjustments BatteryOverspeed is Hazardous Slip RingsPre-Cleaner Oil FilterAir Filter ElementFigure D.1 Major Component Location Section E-1 Theory of Operation SectionTheory of Operation BATTERY, STARTER, ENGINE, ROTOR, STATOR, and Idler Solenoid Theory of OperationRotor Field Feedback and Auxiliary Power Figure E.3 Rotor Field Feedback and Auxiliary PowerWeld WINDING, REACTOR, Range Switch Figure E.4 Weld WINDING, REACTOR, and Range SwitchOutput BRIDGE, Choke Polarity SWITCH, and Output Terminals Ranger 10,000 & Ranger 10,000 Plus Troubleshooting & Repair Section Section F-1Troubleshooting & Repair HOW to USE Troubleshooting GuidePC Board Troubleshooting Procedures Electric ShockTroubleshooting Guide Output ProblemsOutput Problems Field Winding Voltage Test Adjustment Test Troubleshooting Guide Output Problems Engine Problems Make sure the leads are looped Charging Circuit Test Welding Problems Ranger 10,000 & Ranger 10,000 Plus Test Description Rotor Voltage TestMaterials Needed Test Procedure Rotor Resistance Test Rotor Resistance Test Figure F.2 Location of Rotor Slip RingsTroubleshooting & Repair Ranger 10,000 & Ranger 10,000 Plus Auxiliary and Field Winding Test To test the 115 VAC winding Auxiliary and Field Winding TestTo test the 230 VAC winding To test the field winding Ranger 10,000 & Ranger 10,000 Plus Output Rectifier Bridge Test Output Rectifier Bridge Test 26TROUBLESHOOTING & REPAIRF-26Figutpure F.4 Locationctifof Output Rectifier Leads Charging Circuit Test Charging Circuit Test Figure F.5 Location of Voltage RegulatorEngine Throttle Adjustment Test Engine Throttle Adjustment Test Figure F.6 Blower Paddle Marked for STROBE-TACH MethodFigure F.7 Oscilloscope Method Normal Open Circuit Voltage Waveform 115 VAC Supply Scope SettingsHigh Idle no Load Output Control AT Maximum Machine Loaded Typical DC Weld Output Waveform CV ModeMachine Loaded to 200 Amps AT 20 VDC Typical DC Weld Output Waveform CC Mode Machine Loaded to 200 Amps AT 26 VDCTypical AC Weld Output Waveform Machine Loaded to 225 Amps AT 25 VDCAbnormal Open Circuit Weld Voltage Waveform CV Mode Abnormal Open Circuit DC Weld Voltage Waveform Normal Open Circuit Weld Voltage Waveform CV Mode Normal Open Circuit DC Weld Voltage Waveform CC Mode Normal Open Circuit AC Weld Voltage Waveform Ranger 10,000 & Ranger 10,000 Plus Brush Removal and Replacement DescriptionBrush Removal and Replacement ProcedureSlip Rings Figure F.9 Brush LEADS/BRUSHES Retained with Cable TIERanger 10,000 & Ranger 10,000 Plus Printed Circuit Board Removal Replacement Printed Circuit Board Removal and Replacement Figure F.10 Printed Circuit Board LocationReplacement Printed Circuit Board RemovalRanger 10,000 & Ranger 10,000 Plus Output Rectifier Bridge Removal Replacement Remove the case top, then reinstall the fuel cap Output Rectifier Bridge RemovalSection TOC Ranger 10,000 & Ranger 10,000 Plus ENGINE/ROTOR Removal and Replacement InstructionsENGINE/ROTOR Removal Figure F.12 Component LOCATIONS, ENGINE/ROTOR RemovalEngine and Rotor Removal Procedure Rotor Removal Procedure Figure F.13 Engine and Rotor Removed from Stator THRU-BOLTReplacement KIT S20788 Reassembly ProcedureRetest After Repair Electrical Diagrams Electrical Diagrams SectionSection G-1 Electrical Diagrams Wiring Diagram Code 11041 only -M20226Wiring Diagram Code 11095 only M20301 Ranger 10,000 HondaRanger 10,000 Wiring Diagram Code 11398 M21269 Ranger 10,000 Plus Schematic Entire Machine Codes 11395 and 11398 L13105 L13105Schematic Entire Machine CDE 11394 L13103 L13103Schematic Entire Machine Code 11095 & 11253 only L12257 Schematic Entire Machine Code 11151 only L12249-1 L12249Electrical Diagrams Electrical Diagrams