Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
INSTALLATION | ||
|
|
|
TABLE lll
ELECTRICAL DEVICE USE WITH THE RANGER® 10,000 or RANGER® 10,000 PLUS.
Type | Common Electrical Devices | Possible Concerns |
|
|
|
|
|
Resistive | Heaters, toasters, incandescent | NONE |
|
| light bulbs, electric range, hot |
|
|
| pan, skillet, coffee maker. |
|
|
|
|
|
|
Capacitive | TV sets, radios, microwaves, | Voltage spikes or high voltage |
|
| appliances with electrical control. | regulation can cause the capac- |
|
|
| itative elements to fail. Surge |
|
|
| protection, transient protection, |
|
|
| and additional loading is recom- |
|
|
| mended for 100% |
|
|
| operation. DO NOT RUN |
|
|
| THESE DEVICES WITHOUT |
|
|
| ADDITIONAL RESISTIVE |
|
|
| TYPE LOADS. |
|
|
|
|
|
Inductive | These devices require large |
| |
| drills, well pumps, grinders, small | current inrush for starting. |
|
| refrigerators, weed and hedge | Some synchronous motors may |
|
| trimmers | be frequency sensitive to attain |
|
|
| maximum output torque, but |
|
|
| they SHOULD BE SAFE from |
|
|
| any frequency induced failures. |
|
|
|
|
|
Capacitive/Inductive | Computers, high resolution TV sets, | An inductive type line condition- |
|
| complicated electrical equipment. | er along with transient and |
|
|
| surge protection is required, |
|
|
| and liabilities still exist. DO |
|
|
| NOT USE THESE DEVICES |
|
|
| WITH A RANGER® 10,000 |
|
|
|
|
|
The Lincoln Electric Company is not responsible for any damage to electrical components improperly connect- ed to the RANGER® 10,000 or RANGER® 10,000 PLUS.
RANGER® 10,000 & RANGER® 10,000 PLUS