TROUBLESHOOTING & REPAIR | |||||||
|
|
|
|
|
| ||
TROUBLESHOOTING GUIDE |
|
|
|
| Observe Safety Guidelines | ||
|
|
|
|
| detailed in the beginning of this manual. | ||
PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
| |||
(SYMPTOMS) |
| MISADJUSTMENT(S) |
| COURSE OF ACTION | |||
|
|
|
|
|
| ||
|
|
| OUTPUT PROBLEMS |
|
| ||
No weld output, the auxiliary | 1. | Check the open circuit voltage | 1. Disconnect lead W1 from the | ||||
power |
| (OCV) at the welder output ter- | Output Bridge (D1) and check | ||||
normally. Engine runs normally. |
| minals, engine at high idle (3650 | for the presence of 80VAC from | ||||
|
|
| RPM). Normal maximum is 73 | lead W1 to lead W2 on the main | |||
|
|
| to 80VAC. | Normal DC maxi- | stator winding. See wiring dia- | ||
|
|
| mum is 67 to 72VDC. | If the | gram. If the AC voltage is NOT | ||
|
|
| OCV is OK then proceed to | present, the winding in the sta- | |||
|
|
| Step #2. If the OCV is not pre- | tor may be faulty. | Check the | ||
|
|
| sent at the welder output termi- | winding for continuity and test | |||
|
|
| nals, contact your local Lincoln | to be sure it is NOT grounded to | |||
|
|
| Authorized | Field | Service | the stator iron. Replace if nec- | |
|
|
| Facility. |
|
| essary. If the correct AC volt- | |
|
| 2. | Check the | welding | cables, | age is present, proceed to step | |
|
| #2. |
| ||||
|
|
| clamps and electrode holder for |
| |||
|
|
|
|
| |||
|
|
| loose or broken connections. | 2. Check the Reactor, Range | |||
|
|
|
|
|
| Switch (S1) and | associated |
|
|
|
|
|
| wires for loose or faulty connec- | |
|
|
|
|
|
| tions. Check the reactor wind- | |
|
|
|
|
|
| ing for continuity and test to be | |
|
|
|
|
|
| sure it is NOT grounded to the | |
|
|
|
|
|
| reactor iron. |
|
|
|
|
|
|
| 3. Check the Choke (L1), Polarity | |
|
|
|
|
|
| Switch (S2) and | associated |
|
|
|
|
|
| wires for loose or faulty connec- | |
|
|
|
|
|
| tions. Check the choke winding | |
|
|
|
|
|
| for continuity and test to be | |
|
|
|
|
|
| sure it is NOT grounded to the | |
|
|
|
|
|
| choke iron. |
|
|
|
|
|
|
| 4. Check the weld output termi- | |
|
|
|
|
|
| nals and associated wires for | |
|
|
|
|
|
| loose or faulty connections. | |
|
|
|
|
|
| 5. Perform the Output Bridge | |
|
|
|
|
|
| Test. |
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call