TROUBLESHOOTING & REPAIR | |||||
|
|
| |||
TROUBLESHOOTING GUIDE |
| Observe Safety Guidelines | |||
|
| detailed in the beginning of this manual. | |||
PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
| |
(SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION | ||
|
|
|
|
| |
|
| ENGINE PROBLEMS |
|
| |
Engine will not go to high idle when | 1. Make sure the welding cables | 1. Check for broken or faulty con- | |||
attempting to weld. | Welding out- | and connections are tight. | nections in the sensing leads | ||
put is normal when Idler Switch is |
| (#254 and #254A). | Make sure | ||
in “HIGH” position. Automatic idle |
| their connections are tight at | |||
function works properly when the |
| the Electrode Output Terminal | |||
auxiliary power is loaded. |
| and also at the Polarity Switch. | |||
|
|
| See Wiring Diagram. | ||
|
|
| 2. Make sure the leads are looped | ||
|
|
| three times through the current | ||
|
|
| sensor on the Printed Circuit | ||
|
|
| Board. |
| |
|
|
| |||
Engine will not go to high idle when | 1. Make sure the welding cables | 1. Check for broken or faulty con- | |||
attempting to weld or when the | and connections are tight. | nections in the sensing leads. | |||
auxiliary power is loaded. Welding | 2. Automatic idler may not func- | (#254 and #254A). | Make sure | ||
output and auxiliary power output | their connections | are tight at | |||
tion if the auxiliary power is | |||||
is normal when Idler Switch is in | the Electrode Terminal and also | ||||
loaded to less than 150 Watts. | |||||
the “HIGH” position. |
| at the Polarity Switch. See | |||
|
| ||||
|
|
| Wiring Diagram. |
| |
|
|
| 2. Check lead #3, making sure it is | ||
|
|
| looped through the current sen- | ||
|
|
| sor on the Printed Circuit Board. | ||
|
|
| 3. The Printed Circuit Board may | ||
|
|
| be faulty. Replace. |
| |
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call