ENGINE PROBLEMS

 

 

Engine will not go to high idle when

1. Make sure the welding cables

1. Check for broken or faulty con-

attempting to weld.

Welding out-

and connections are tight.

nections in the sensing leads

put is normal when Idler Switch is

 

(#254 and #254A).

Make sure

in “HIGH” position. Automatic idle

 

their connections are tight at

function works properly when the

 

the Electrode Output Terminal

auxiliary power is loaded.

 

and also at the Polarity Switch.

 

 

 

See Wiring Diagram.

 

 

 

2. Make sure the leads are looped

 

 

 

three times through the current

 

 

 

sensor on the Printed Circuit

 

 

 

Board.

 

 

 

 

Engine will not go to high idle when

1. Make sure the welding cables

1. Check for broken or faulty con-

attempting to weld or when the

and connections are tight.

nections in the sensing leads.

auxiliary power is loaded. Welding

2. Automatic idler may not func-

(#254 and #254A).

Make sure

output and auxiliary power output

their connections

are tight at

tion if the auxiliary power is

is normal when Idler Switch is in

the Electrode Terminal and also

loaded to less than 150 Watts.

the “HIGH” position.

 

at the Polarity Switch. See

 

 

 

 

 

Wiring Diagram.

 

 

 

 

2. Check lead #3, making sure it is

 

 

 

looped through the current sen-

 

 

 

sor on the Printed Circuit Board.

 

 

 

3. The Printed Circuit Board may

 

 

 

be faulty. Replace.

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.

RANGER® 10,000 & RANGER® 10,000 PLUS

Image 51
Contents Ranger 10,000 /10,000 Plus Safety Powered equipmentFor Engine Fumes and Gases ARC Rays can burnWelding and Cutting Sparks can cause fire or Explosion Cylinder may explode If damagedIii Précautions DE Sûreté Master Table of Contents for ALL Sections Table of Contents Installation SectionSection A-1 Height Width Depth Weight InstallationHorsepower Operating Speed RPM Towing Safety PrecautionsSpark Arrester Machine GroundingCan cause fire or explosion PRE-OPERATION ServiceGasoline Vehicle MountingLifting Welding Output CablesTotal Combined Length of Electrode and Work Cables Angle of OperationWelder Operation Connection of Lincoln Electric Wire FeedersInstructions StackingMotor Starting Auxiliary Power120/240 Volt Dual Voltage Receptacle Duplex ReceptaclesNot USE These Devices With a Ranger 10,000 These Devices Without Additional Resistive Type LoadsStandby Power Connections Simultaneous Welding and PowerFigure A.1 Ranger 10,000 & Ranger 10,000 Plus Operation Section Section B-1Operation Engine Switch OperationWelder Controls Function and Operation Control Dial Polarity SwitchRange Switch Kohler Honda Robin / Subaru 20 H.P. CommandStopping the Engine STARTING/SHUTDOWN InstructionsBREAK-IN Period Starting the EngineWire Feed Welding Processes Constant Voltage Stick Constant Current WeldingTIG Constant Current Welding Summary of Welding Processes Start Switch Wire FEED, LN-15Section C-1 Accessories SectionOptional Equipment Field Installed AccessoriesPlasma Cutting Recommended EquipmentStick TIG WeldingRanger 10,000 & Ranger 10,000 Plus Section D-1 Maintenance SectionMaintenance Safety PrecautionsKohler Honda OIL Filter Change AIR Cleaner and Other MaintenanceSlip Rings Engine AdjustmentsBattery Overspeed is HazardousElement Pre-CleanerOil Filter Air FilterFigure D.1 Major Component Location Theory of Operation Section Section E-1Theory of Operation Theory of Operation BATTERY, STARTER, ENGINE, ROTOR, STATOR, and Idler SolenoidFigure E.3 Rotor Field Feedback and Auxiliary Power Rotor Field Feedback and Auxiliary PowerFigure E.4 Weld WINDING, REACTOR, and Range Switch Weld WINDING, REACTOR, Range SwitchOutput BRIDGE, Choke Polarity SWITCH, and Output Terminals Ranger 10,000 & Ranger 10,000 Plus Section F-1 Troubleshooting & Repair SectionHOW to USE Troubleshooting Guide Troubleshooting & RepairElectric Shock PC Board Troubleshooting ProceduresOutput Problems Troubleshooting GuideOutput Problems Field Winding Voltage Test Adjustment Test Troubleshooting Guide Output Problems Engine Problems Make sure the leads are looped Charging Circuit Test Welding Problems Ranger 10,000 & Ranger 10,000 Plus Rotor Voltage Test Test DescriptionMaterials Needed Test Procedure Rotor Resistance Test Figure F.2 Location of Rotor Slip Rings Rotor Resistance TestTroubleshooting & Repair Ranger 10,000 & Ranger 10,000 Plus Auxiliary and Field Winding Test Auxiliary and Field Winding Test To test the 115 VAC windingTo test the 230 VAC winding To test the field winding Ranger 10,000 & Ranger 10,000 Plus Output Rectifier Bridge Test 26TROUBLESHOOTING & REPAIRF-26 Output Rectifier Bridge TestFigutpure F.4 Locationctifof Output Rectifier Leads Charging Circuit Test Figure F.5 Location of Voltage Regulator Charging Circuit TestEngine Throttle Adjustment Test Figure F.6 Blower Paddle Marked for STROBE-TACH Method Engine Throttle Adjustment TestFigure F.7 Oscilloscope Method Scope Settings Normal Open Circuit Voltage Waveform 115 VAC SupplyHigh Idle no Load Output Control AT Maximum Typical DC Weld Output Waveform CV Mode Machine LoadedMachine Loaded to 200 Amps AT 20 VDC Machine Loaded to 200 Amps AT 26 VDC Typical DC Weld Output Waveform CC ModeMachine Loaded to 225 Amps AT 25 VDC Typical AC Weld Output WaveformAbnormal Open Circuit Weld Voltage Waveform CV Mode Abnormal Open Circuit DC Weld Voltage Waveform Normal Open Circuit Weld Voltage Waveform CV Mode Normal Open Circuit DC Weld Voltage Waveform CC Mode Normal Open Circuit AC Weld Voltage Waveform Ranger 10,000 & Ranger 10,000 Plus Description Brush Removal and ReplacementProcedure Brush Removal and ReplacementFigure F.9 Brush LEADS/BRUSHES Retained with Cable TIE Slip RingsRanger 10,000 & Ranger 10,000 Plus Printed Circuit Board Removal Replacement Figure F.10 Printed Circuit Board Location Printed Circuit Board Removal and ReplacementPrinted Circuit Board Removal ReplacementRanger 10,000 & Ranger 10,000 Plus Output Rectifier Bridge Removal Replacement Output Rectifier Bridge Removal Remove the case top, then reinstall the fuel capSection TOC Ranger 10,000 & Ranger 10,000 Plus Instructions ENGINE/ROTOR Removal and ReplacementFigure F.12 Component LOCATIONS, ENGINE/ROTOR Removal ENGINE/ROTOR RemovalEngine and Rotor Removal Procedure Figure F.13 Engine and Rotor Removed from Stator THRU-BOLT Rotor Removal ProcedureReassembly Procedure Replacement KIT S20788Retest After Repair Electrical Diagrams Section Electrical DiagramsSection G-1 Wiring Diagram Code 11041 only -M20226 Electrical DiagramsRanger 10,000 Honda Wiring Diagram Code 11095 only M20301Ranger 10,000 Wiring Diagram Code 11398 M21269 Ranger 10,000 Plus L13105 Schematic Entire Machine Codes 11395 and 11398 L13105L13103 Schematic Entire Machine CDE 11394 L13103Schematic Entire Machine Code 11095 & 11253 only L12257 L12249 Schematic Entire Machine Code 11151 only L12249-1Electrical Diagrams Electrical Diagrams