Lincoln Electric SVM168-B Summary of Welding Processes, Start Switch Wire FEED, LN-15

Page 24

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

 

B-6

 

OPERATION

B-6

 

 

 

 

 

 

 

 

 

 

Summary of Welding Processes

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL

 

 

ELECTRODE

 

 

 

PROCESS

CABLE

 

IDLE

WHEN NOT

TO START

 

 

 

USED

 

MODE

WELDING

WELDING

 

 

 

 

 

 

 

 

 

 

STICK

No

 

AUTO

Hot

Touch electrode to work.

 

 

 

 

 

 

 

Welding starts immediately

 

 

 

 

 

 

 

and engine goes to high

 

 

 

 

 

 

 

idle.

 

 

WIRE FEED, LN-25 WITH

No

 

AUTO

Cold

Press gun trigger, LN-25

 

 

INTERNAL CONTACTOR

 

 

 

 

contactor closes. Welding

 

 

 

 

 

 

 

starts immediately and

 

 

 

 

 

 

 

engine goes to high idle.

 

 

 

 

 

 

 

NOTE: Output Control

 

 

 

 

 

 

 

must be set above “3”

 

 

TIG, TIG MODULE WITH

Yes

 

High

Cold

Press Arc Start Switch

 

 

WITH CONTACTOR KIT

 

 

 

 

contactor closes,

 

 

CONTROL CABLE, & ARC

 

 

 

 

welding starts immediately.

 

 

START SWITCH

 

 

 

 

 

 

 

WIRE FEED, LN-15

No

 

High

Cold

Press gun trigger.

 

 

ACROSS the ARC

 

 

 

 

LN-15 contactor closes,

 

 

(has internal contactor)

 

 

 

 

Welding starts immediately

 

 

 

 

 

 

 

Note: Output Control must

 

 

 

 

 

 

 

be set above “3”.

 

RANGER® 10,000 & RANGER® 10,000 PLUS

Image 24
Contents Ranger 10,000 /10,000 Plus Safety Powered equipmentFor Engine ARC Rays can burn Fumes and GasesWelding and Cutting Sparks can cause fire or Explosion Cylinder may explode If damagedIii Précautions DE Sûreté Master Table of Contents for ALL Sections Table of Contents Installation SectionSection A-1 Installation Height Width Depth WeightHorsepower Operating Speed RPM Safety Precautions Spark ArresterMachine Grounding TowingPRE-OPERATION Service GasolineVehicle Mounting Can cause fire or explosionWelding Output Cables Total Combined Length of Electrode and Work CablesAngle of Operation LiftingConnection of Lincoln Electric Wire Feeders InstructionsStacking Welder OperationAuxiliary Power 120/240 Volt Dual Voltage ReceptacleDuplex Receptacles Motor StartingThese Devices Without Additional Resistive Type Loads Not USE These Devices With a Ranger 10,000Simultaneous Welding and Power Standby Power ConnectionsFigure A.1 Ranger 10,000 & Ranger 10,000 Plus Operation Section Section B-1Operation Engine Switch OperationWelder Controls Function and Operation Polarity Switch Range SwitchKohler Honda Robin / Subaru 20 H.P. Command Control DialSTARTING/SHUTDOWN Instructions BREAK-IN PeriodStarting the Engine Stopping the EngineWire Feed Welding Processes Constant Voltage Stick Constant Current WeldingTIG Constant Current Welding Start Switch Wire FEED, LN-15 Summary of Welding ProcessesAccessories Section Section C-1Accessories Optional Equipment Field InstalledRecommended Equipment StickTIG Welding Plasma CuttingRanger 10,000 & Ranger 10,000 Plus Maintenance Section Section D-1Maintenance Safety PrecautionsKohler Honda AIR Cleaner and Other Maintenance OIL Filter ChangeEngine Adjustments BatteryOverspeed is Hazardous Slip RingsPre-Cleaner Oil FilterAir Filter ElementFigure D.1 Major Component Location Theory of Operation Section Section E-1Theory of Operation BATTERY, STARTER, ENGINE, ROTOR, STATOR, and Idler Solenoid Theory of OperationRotor Field Feedback and Auxiliary Power Figure E.3 Rotor Field Feedback and Auxiliary PowerWeld WINDING, REACTOR, Range Switch Figure E.4 Weld WINDING, REACTOR, and Range SwitchOutput BRIDGE, Choke Polarity SWITCH, and Output Terminals Ranger 10,000 & Ranger 10,000 Plus Troubleshooting & Repair Section Section F-1Troubleshooting & Repair HOW to USE Troubleshooting GuidePC Board Troubleshooting Procedures Electric ShockTroubleshooting Guide Output ProblemsOutput Problems Field Winding Voltage Test Adjustment Test Troubleshooting Guide Output Problems Engine Problems Make sure the leads are looped Charging Circuit Test Welding Problems Ranger 10,000 & Ranger 10,000 Plus Rotor Voltage Test Test DescriptionMaterials Needed Test Procedure Rotor Resistance Test Rotor Resistance Test Figure F.2 Location of Rotor Slip RingsTroubleshooting & Repair Ranger 10,000 & Ranger 10,000 Plus Auxiliary and Field Winding Test Auxiliary and Field Winding Test To test the 115 VAC windingTo test the 230 VAC winding To test the field winding Ranger 10,000 & Ranger 10,000 Plus Output Rectifier Bridge Test 26TROUBLESHOOTING & REPAIRF-26 Output Rectifier Bridge TestFigutpure F.4 Locationctifof Output Rectifier Leads Charging Circuit Test Charging Circuit Test Figure F.5 Location of Voltage RegulatorEngine Throttle Adjustment Test Engine Throttle Adjustment Test Figure F.6 Blower Paddle Marked for STROBE-TACH MethodFigure F.7 Oscilloscope Method Scope Settings Normal Open Circuit Voltage Waveform 115 VAC SupplyHigh Idle no Load Output Control AT Maximum Typical DC Weld Output Waveform CV Mode Machine LoadedMachine Loaded to 200 Amps AT 20 VDC Typical DC Weld Output Waveform CC Mode Machine Loaded to 200 Amps AT 26 VDCTypical AC Weld Output Waveform Machine Loaded to 225 Amps AT 25 VDCAbnormal Open Circuit Weld Voltage Waveform CV Mode Abnormal Open Circuit DC Weld Voltage Waveform Normal Open Circuit Weld Voltage Waveform CV Mode Normal Open Circuit DC Weld Voltage Waveform CC Mode Normal Open Circuit AC Weld Voltage Waveform Ranger 10,000 & Ranger 10,000 Plus Brush Removal and Replacement DescriptionBrush Removal and Replacement ProcedureSlip Rings Figure F.9 Brush LEADS/BRUSHES Retained with Cable TIERanger 10,000 & Ranger 10,000 Plus Printed Circuit Board Removal Replacement Printed Circuit Board Removal and Replacement Figure F.10 Printed Circuit Board LocationReplacement Printed Circuit Board RemovalRanger 10,000 & Ranger 10,000 Plus Output Rectifier Bridge Removal Replacement Remove the case top, then reinstall the fuel cap Output Rectifier Bridge RemovalSection TOC Ranger 10,000 & Ranger 10,000 Plus ENGINE/ROTOR Removal and Replacement InstructionsENGINE/ROTOR Removal Figure F.12 Component LOCATIONS, ENGINE/ROTOR RemovalEngine and Rotor Removal Procedure Rotor Removal Procedure Figure F.13 Engine and Rotor Removed from Stator THRU-BOLTReplacement KIT S20788 Reassembly ProcedureRetest After Repair Electrical Diagrams Section Electrical DiagramsSection G-1 Electrical Diagrams Wiring Diagram Code 11041 only -M20226Wiring Diagram Code 11095 only M20301 Ranger 10,000 HondaRanger 10,000 Wiring Diagram Code 11398 M21269 Ranger 10,000 Plus Schematic Entire Machine Codes 11395 and 11398 L13105 L13105Schematic Entire Machine CDE 11394 L13103 L13103Schematic Entire Machine Code 11095 & 11253 only L12257 Schematic Entire Machine Code 11151 only L12249-1 L12249Electrical Diagrams Electrical Diagrams