TROUBLESHOOTING & REPAIR

MAIN INVERTER BOARD VOLTAGE TEST

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.

DESCRIPTION

This test will help determine if the main inverter board is receiving the correct input voltages and if the correct regulated voltages are being processed and maintained by the main inverter board.

MATERIALS NEEDED

Volt/Ohmmeter

7mm Nut Driver

4mm Allen Wrench

Crescent Wrench

PRO-CUT 25

Image 55
Contents PRO-CUT Safety Cylinder may explode if damaged Précautions DE Sûreté SafetyMaster Table of Contents for ALL Sections PRO-CUT Installation Section Table of ContentsTechnical Specifications PRO-CUT 25 K1756-1 InstallationInput Electrical Connections Safety Precautions Electric Shock can KillSelect Proper Location High Frequency Interference ProtectionGAS Input Connections Torch Output ConnectionsPRO-CUT Table of Contents Operation Section Description Safety PrecautionsPreheat Temperature for Plasma Cutting OperationDesign Features Advantages Operational Features and ControlsUser Responsibility Consumable Life Cutting CapabilityLimitations Controls and SettingsPilot ARC Discussion Apparently wrong, reset the machine by turningGeneral In All Cases Procedure RecommendationsPRO-CUT Accessories General Options Accessories Maintenance Electric Shock can kill Routine MaintenancePRO CUT PRO-CUT Table of Contents Theory of Operation Section General Description Theory of OperationInput Line VOLTAGE, and Auxiliary Transformer Figure E.3 Precharge and Protection Precharge and ProtectionReturn Return to Section TOC Main TransformerFigure E.5 Plasma Output Section and Torch Figure E.6 Control Board Control BoardProtection Circuits Safety PARTS-IN-PLACE ProtectionAccidental Operation Protection Insulated Gate Bipolar Transistor Igbt Operation Table of Contents Troubleshooting & Repair Section HOW to USE Troubleshooting Guide Troubleshooting & RepairPC Board Troubleshooting Procedures Output Problems Function Problems See the Operation section Troubleshooting & Repair LED Function Problems Description Input Filter Capacitor Discharge ProcedureRight Side of Machine Discharge ProcedureMain Inverter Board Resistance Test Right Side of Machine IGBT’s D2 D1 D11 D10 PRO-CUT Input Board Voltage Test Test Points Fan PRO-CUT Main Inverter Board Voltage Test P2 P1 P2 P1 PRO-CUT Torch Continuity and Solenoid Test Torch Continuity and Solenoid Test Torch Continuity and Solenoid Test PRO-CUT AIR/GAS Solenoid Test AIR/GAS Solenoid Test Control Board Removal and Replacement Small Red Cap Screws Over tighten Input Board Removal and Replacement Input Board Input Board Removal & Replacement PRO-CUT Main Inverter Board Removal and Replacement Main Board Main Inverter Board Removal & Replacement PRO-CUT Switch Removal and Replacement PRO FAN Removal and Replacement Fan Do Not Over tighten Machine Input and Output Retest After RepairTable of Contents Electrical Diagrams Section Electrical DiagramsInput Voltage Board Pressure SCHEMATIC- Control Printed Circuit Board Sheet Electrical Diagrams Electrical Diagrams PC Board Assembly Main Inverter Board PC Board Assembly Input Board Cutting Current Path SVM Error Reporting Form