Return to Section TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR |
CONTROL BOARD REMOVAL AND REPLACEMENT (continued)
FIGURE F.13 - CONTROL BOARD LOCATION
Control
Board
Return to Section TOC
Return to Master TOC
|
| PO |
|
|
| ON | WER |
|
|
| GAS | PRESSURE |
| |
|
|
| TH | |
|
|
|
| |
|
|
|
| ERMAL |
| OFF | PURGE | SAFETY | |
| ! | |||
LIN | C |
|
|
|
E |
|
|
| |
LE OL |
|
|
| |
| CT N |
|
|
|
| RIC |
|
|
|
|
| PRO- |
|
|
|
| CUT | 25 |
to Section TOC
to Master TOC
PROCEDURE
1.Remove input power to the PRO-CUT 25 machine.
2.Remove carrying handle using a 4mm allen wrench.
3.Using a crescent wrench, carefully remove the plastic nut from around the pressure regulator located on the top of the machine.
4.Using a 7mm nut driver, remove the case wrap- around.
5.Perform Capacitor Discharge Procedure.
6.Using a very small flathead screwdriver or a thin knife blade, carefully remove the red plastic cap from the front of the plastic OUTPUT knob located on the front of the machine. See Figure F14.
Return
Return
FIGURE F.14 - SMALL RED CAP REMOVAL
Return to Section TOC
Return to Master TOC
Small Red
Cap
POWER
| ON | GAS PR |
|
|
| ESSURE | T |
|
|
| HERMAL |
| OFF | PURGE | SAFETY |
| ! | ||
LIN | C |
|
|
E |
|
| |
LE OL |
|
| |
| CT N |
|
|
| RIC |
|
|
|
| PRO- |
|
|
| CUT | 25 |
|
|
|