A-1

 

 

INSTALLATION

 

A-1

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS - Commander 300

 

 

 

 

 

 

 

 

 

 

 

 

INPUT - DIESEL ENGINE

 

 

 

 

 

 

 

Make/Model

Displacement

Description

 

Speed (RPM)

Starting

Capacities

 

Diesel Engine

 

 

 

 

System

 

 

 

 

 

 

 

 

 

 

 

125 cu. in

 

 

 

 

 

Deutz

(2.05 L)

3 cylinder

 

 

 

 

F3L 1011F

Bore x Stroke

31 HP(23 kw)

 

 

 

 

(Codes 11199

3.89” x 4.13”

@ 1800 RPM

 

 

 

Fuel: 25 gal.

and Below)

(99mm x 105mm)

 

 

 

 

94.6 L

 

 

 

 

 

High Idle 1900

12 VDC battery

 

 

 

 

 

 

Low Idle 1475

& Starter

 

Deutz

142 cu. in

 

 

Full Load 1800

 

Oil: 6.3 Qts.

F3L2011

(2.33L)

3 cylinder

 

 

 

6.0 L

(Codes 11200

Bore x Stroke

32 HP(24 kw)

 

 

 

 

and above)

3.70” x 4.41”

@ 1800 RPM

 

 

 

 

 

 

(94mm x 112mm)

 

 

 

 

 

RATED OUTPUT - WELDER

Duty Cycle

 

 

Welding Output

 

Volts at Rated Amps

100%

 

 

300 amps (DC multi-purpose)

 

 

32 volts

 

 

 

 

 

 

 

 

 

60%

 

 

375 amps (DC multi-purpose)

 

 

34 volts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT - WELDER AND GENERATOR

 

 

 

 

 

 

 

 

 

Welding Range

 

Open Circuit Voltage

 

Auxiliary Power1

 

 

30-300 Amps CC / CV TIG

 

80 Max OCV

 

 

120/240 VAC

 

 

 

 

 

 

 

 

10,000 Watts, 60 Hz.

 

 

 

 

@1900 RPM

 

 

100% Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

HEIGHT2

 

WIDTH

 

DEPTH

 

 

WEIGHT

 

 

 

 

 

 

 

 

 

1325 lbs.(601 kg)

 

 

 

 

 

 

 

 

 

(Codes 11199 and

 

 

 

 

 

 

 

 

 

below)

 

 

 

 

 

 

 

 

40.0 in.

 

31.5 in.

 

63.1 in.

 

 

1327 lbs.(602 kg)

 

 

 

 

 

 

 

 

 

(Code 11200)

1016.0 mm

 

800.1 mm

 

1602.7 mm

 

 

 

 

 

 

 

 

 

 

1332 lbs.(604 kg)

 

 

 

 

 

 

 

 

 

(Code 11201)

 

 

 

 

 

 

 

 

 

 

1.Output rating in watts is equivalent to volt-amperes at unity power factor.

Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

2.Top of Enclosure. Add 8.6” (218.4mm) for exhaust.

COMMANDER 300

Image 13
Contents Safety Depends on You CommanderCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Section D Section CSection E Section FSafety Precautions InstallationLocation / Ventilation High Altitude Operation LiftingTowing Vehicle MountingEngine Cooling System Battery Connection PRE-OPERATION Engine ServiceOIL Fuel USE Diesel Fuel onlyHigh Frequency Generators for TIG Applications Remote ControlWelding Terminals HEIGHT2 Width Depth Weight Welding Range Open Circuit Voltage Auxiliary Power1Bore x Stroke Duty Cycle Welding Output Volts at Rated AmpsStandby Power Connections Auxiliary Power ReceptaclesWelding Output Cables Machine GroundingPower Connection of the LN-25 to the Commander Connection of Lincoln Electric Wire FeedersConnection of LN-7 or LN-8 to the Commander Across-The-Arc Model Connection of LN-15 to the COM- ManderControl Cable Model Design Features and Advantages Safety InstructionsOperation General DescriptionOther Features For Auxiliary PowerK1585-1 Commander 300 Standard Model Welding CapabilityRUN- Stop Switch Controls and SettingsStart Push Button Fuel Level Gauge and LightEngine Alternator Ammeter K1585 Idler SwitchHour Meter Auxiliary Power Controls Starting the Engine Engine OperationStopping the Engine BREAK-IN Period Welder OperationTypical Fuel Consumption Stick WeldingConstant Current CC Welding TIG WeldingTable B.3 Typical Current Ranges 1 for Tungsten ELECTRODES2 Commander 300 Settings When Using the K799 HI-FREQ UnitElectrode Current Range Diameter ARC GougingParalleling Simultaneous Welding and AUXIL- Iary Power Loads Auxiliary Power OperationOptional Field Installed Accessories AccessoriesRecommended Optional Equipment Routine and Periodic Maintenance MaintenanceEngine Maintenance Cooling System Cooling Blower Belt Fuel FiltersWelder / Generator Maintenance Nameplates / Warning Decals MaintenanceMake Part Number Table D.1 Engine Maintenance ComponentsHOW to USE Troubleshooting Guide TroubleshootingPossible Areas Symptoms Misadjustments Course of ActionFunction Problems Output Problems Diagrams Commander 300 Wiring Diagram for Codes 10871 and belowCommander 300 Wiring Diagram for Codes 10871 and Above Commander 300 Wiring Diagram for Codes 10950 Commander 300 Wiring Diagram for Codes 11200 and Above Connection Diagram DIAGRAMSF-5Diagram Commander Commander / K867 / K775 / LN-7 Connection DiagramDIAGRAMSF-7 DIAGRAMSF-8 Commander / K867 / LN-8 Connection Diagram DIAGRAMSF-10 DIAGRAMSF-11 S24787-6 DiagramDiagram DIAGRAMSF-14 DIAGRAMSF-15 DIAGRAMSF-16 24.79 Dimension PrintCommander Commander Precaucion Aviso DE