Lincoln Electric IM700-D manual Commander / K867 / LN-8 Connection Diagram

Page 47

COMMANDER 300

COMMANDER / K867 / LN-8 CONNECTION DIAGRAM

CONNECTION

F-9

 

 

 

 

WARNING

 

 

 

 

 

Do not operate with panels open.

 

 

Keep guards in place.

 

DIAGRAM:

 

Disconnect NEGATIVE (-) BATTERY LEAD

 

 

Keep away from moving parts.

 

 

 

 

 

 

 

before servicing.

 

 

Only qualified personnel should install,use

 

 

 

Do not touch electrically live parts.

 

 

or service this equipment.

 

 

 

 

SPARE

}

 

 

 

 

41

 

 

 

 

82

 

 

 

LN-8

 

 

81

 

N.C.

 

WIRE

 

 

42

 

 

 

FEEDER

 

 

 

 

 

DIAGRAMS

 

 

31

 

31

 

 

14 PIN

32

 

32

 

 

 

 

 

 

 

 

 

AMPHENOL

2

 

2

 

 

 

 

 

 

 

 

 

4

 

4

 

 

ELECTRODE

TO WORK

21

 

21

K196

 

 

K867 UNIVERSAL

 

 

 

 

 

GND

 

GND

INPUT CABLE

 

 

ADAPTER PLUG

 

 

 

 

 

 

 

 

 

TO WORK

75

 

A

 

 

 

ELECTRODE CABLE

76

 

B

 

 

 

77

}

 

 

 

 

TO WIRE FEED UNIT

C

 

 

 

 

 

 

 

 

CAUTION :

N.D.

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE

APPICATIONS. SEE OPERATING MANUAL.

N.B. USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE SELECTOR SWITCH TO "WIRE WELDING CV".

N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.

N.D. SPLICE LEADS AND INSULATE.

7-2000

F-9

S23989

Image 47
Contents Safety Depends on You CommanderCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Section F Section CSection D Section ELocation / Ventilation InstallationSafety Precautions Vehicle Mounting LiftingHigh Altitude Operation TowingFuel USE Diesel Fuel only PRE-OPERATION Engine ServiceEngine Cooling System Battery Connection OILWelding Terminals Remote ControlHigh Frequency Generators for TIG Applications Duty Cycle Welding Output Volts at Rated Amps Welding Range Open Circuit Voltage Auxiliary Power1HEIGHT2 Width Depth Weight Bore x StrokeMachine Grounding Auxiliary Power ReceptaclesStandby Power Connections Welding Output CablesPower Connection of LN-7 or LN-8 to the Commander Connection of Lincoln Electric Wire FeedersConnection of the LN-25 to the Commander Control Cable Model Connection of LN-15 to the COM- ManderAcross-The-Arc Model General Description Safety InstructionsDesign Features and Advantages OperationWelding Capability For Auxiliary PowerOther Features K1585-1 Commander 300 Standard ModelFuel Level Gauge and Light Controls and SettingsRUN- Stop Switch Start Push ButtonHour Meter Idler SwitchEngine Alternator Ammeter K1585 Auxiliary Power Controls Stopping the Engine Engine OperationStarting the Engine Stick Welding Welder OperationBREAK-IN Period Typical Fuel ConsumptionConstant Current CC Welding TIG WeldingTable B.3 Typical Current Ranges 1 for Tungsten ELECTRODES2 Commander 300 Settings When Using the K799 HI-FREQ UnitParalleling ARC GougingElectrode Current Range Diameter Simultaneous Welding and AUXIL- Iary Power Loads Auxiliary Power OperationOptional Field Installed Accessories AccessoriesRecommended Optional Equipment Engine Maintenance MaintenanceRoutine and Periodic Maintenance Cooling System Cooling Blower Belt Fuel FiltersWelder / Generator Maintenance Nameplates / Warning Decals MaintenanceMake Part Number Table D.1 Engine Maintenance ComponentsHOW to USE Troubleshooting Guide TroubleshootingPossible Areas Symptoms Misadjustments Course of ActionFunction Problems Output Problems Diagrams Commander 300 Wiring Diagram for Codes 10871 and belowCommander 300 Wiring Diagram for Codes 10871 and Above Commander 300 Wiring Diagram for Codes 10950 Commander 300 Wiring Diagram for Codes 11200 and Above Connection Diagram DIAGRAMSF-5Diagram Commander Commander / K867 / K775 / LN-7 Connection DiagramDIAGRAMSF-7 DIAGRAMSF-8 Commander / K867 / LN-8 Connection Diagram DIAGRAMSF-10 DIAGRAMSF-11 S24787-6 DiagramDiagram DIAGRAMSF-14 DIAGRAMSF-15 DIAGRAMSF-16 24.79 Dimension PrintCommander Commander Precaucion Aviso DE