Lincoln Electric IM700-D manual Welding Sparks can cause fire or explosion, Iii

Page 4

iii

SAFETY

iii

WELDING SPARKS can cause fire or explosion.

6.a. Remove fire hazards from the welding area. If this is not possible, cover them to prevent the welding sparks from starting a fire. Remember that welding sparks and hot

materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.

6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equipment being used.

6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.

6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even though they have been “cleaned”. For information, purchase “Recommended Safe Practices for the Preparation for Welding and Cutting of Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society (see address above).

6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.

6.f. Sparks and spatter are thrown from the welding arc. Wear oil free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.

6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate circuits. This can create fire hazards or overheat lifting chains or cables until they fail.

6.h. Also see item 1.c.

CYLINDER may explode if damaged.

7.a. Use only compressed gas cylinders

containing the correct shielding gas for the process used and properly operating regulators designed for the gas and

pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.

7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.

7.c. Cylinders should be located:

Away from areas where they may be struck or subjected to physical damage.

A safe distance from arc welding or cutting operations and any other source of heat, sparks, or flame.

7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.

7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.

7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.

7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.

FOR ELECTRICALLY powered equipment.

8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.

8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.

8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.

Mar ‘95

Image 4
Contents Commander Safety Depends on YouSafety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Section C Section DSection E Section FSafety Precautions InstallationLocation / Ventilation Lifting High Altitude OperationTowing Vehicle MountingPRE-OPERATION Engine Service Engine Cooling System Battery ConnectionOIL Fuel USE Diesel Fuel onlyHigh Frequency Generators for TIG Applications Remote ControlWelding Terminals Welding Range Open Circuit Voltage Auxiliary Power1 HEIGHT2 Width Depth WeightBore x Stroke Duty Cycle Welding Output Volts at Rated AmpsAuxiliary Power Receptacles Standby Power ConnectionsWelding Output Cables Machine GroundingPower Connection of the LN-25 to the Commander Connection of Lincoln Electric Wire FeedersConnection of LN-7 or LN-8 to the Commander Across-The-Arc Model Connection of LN-15 to the COM- ManderControl Cable Model Safety Instructions Design Features and AdvantagesOperation General DescriptionFor Auxiliary Power Other FeaturesK1585-1 Commander 300 Standard Model Welding CapabilityControls and Settings RUN- Stop SwitchStart Push Button Fuel Level Gauge and LightEngine Alternator Ammeter K1585 Idler SwitchHour Meter Auxiliary Power Controls Starting the Engine Engine OperationStopping the Engine Welder Operation BREAK-IN PeriodTypical Fuel Consumption Stick WeldingTIG Welding Constant Current CC WeldingCommander 300 Settings When Using the K799 HI-FREQ Unit Table B.3 Typical Current Ranges 1 for Tungsten ELECTRODES2Electrode Current Range Diameter ARC GougingParalleling Auxiliary Power Operation Simultaneous Welding and AUXIL- Iary Power LoadsAccessories Optional Field Installed AccessoriesRecommended Optional Equipment Routine and Periodic Maintenance MaintenanceEngine Maintenance Fuel Filters Cooling System Cooling Blower BeltNameplates / Warning Decals Maintenance Welder / Generator MaintenanceTable D.1 Engine Maintenance Components Make Part NumberTroubleshooting HOW to USE Troubleshooting GuideSymptoms Misadjustments Course of Action Possible AreasFunction Problems Output Problems Commander 300 Wiring Diagram for Codes 10871 and below DiagramsCommander 300 Wiring Diagram for Codes 10871 and Above Commander 300 Wiring Diagram for Codes 10950 Commander 300 Wiring Diagram for Codes 11200 and Above DIAGRAMSF-5 Connection DiagramCommander / K867 / K775 / LN-7 Connection Diagram Diagram CommanderDIAGRAMSF-7 DIAGRAMSF-8 Commander / K867 / LN-8 Connection Diagram DIAGRAMSF-10 DIAGRAMSF-11 Diagram S24787-6Diagram DIAGRAMSF-14 DIAGRAMSF-15 DIAGRAMSF-16 Dimension Print 24.79Commander Commander Precaucion Aviso DE