Lincoln Electric IM658-A K590-6 Water Connection KIT for Drive only, K659-1 GAS Guard Regulator

Page 45

C-12

ACCESSORIES

C-12

 

 

 

K590-6 WATER CONNECTION KIT (FOR DRIVE ONLY)

Install per the instructions shipped with the kit.

K1536-1 WATER FLOW SENSOR KIT

Install per the instructions shipped with the kit

K659-1 GAS GUARD REGULATOR

Adjustable flow regulator with removable adjuster key for CO2 and Argon blend gases. Mounts onto feeder inlet, and reduces gas waste and arc start “blow” by reducing surge caused by excess pressure in supply hose.

Install the 5/8-18 male outlet of the regulator to the 5/8-18 female gas inlet on the back panel of the wire drive. Secure fitting with flow adjuster key at top. Attach gas supply to 5/8-18 female inlet of regulator per INSTALLATION section.

K1556-1 LIGHT DUTY CASTER KIT

This option provides 4 casters and all required hard- ware to mount it to the Power Feed Wire Feeder.

K1574-1 SECURITY DOOR (LARGE)

K1574-1 Security Door Installation into the Control Box Cabinet

1.Turn off power.

2.Unlatch and swing open the small door. Remove the two screws from the horizontal hinge rod. Save the screws.

3.While holding the door so it doesnʼt fall, Slide the rod out sideways releasing the door.

4.Position the new door between the panel holes and re-install the rod so the screw holes can be accessed.

5.Replace the two screws and tighten.

6.Swing the door into the up position. A lock may be installed through the side holes for security purposes.

K1555-2 INSULATED LIFT HOOK

For applications where an insulated lift hook is required. This kit provides an easily installed, heavy duty insulated lift eye that mounts to the wire reel stand mast. See the instructions provided with the kit for installation.

K1551-2 INCOMING BUSHING

(4 Ball Roller) (Standard on codes 10600 and up)

This ball bearing equipped incoming bushing can be used in place of the standard incoming wire bushing, when feeding solid steel or cored wire electrodes. It significantly reduces any abrasion to the electrode wire where it enters the feed head. This results in even smoother, more trouble free operation.

POWER FEED 10 DUAL

Image 45
Contents OPERATOR’S Manual Safety Electric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents Section E Section FP346 Series Installation Safety Precautions Mounting the Wire Drive UnitBoom Mounting of Wire Drive Unit Control Cable Mounting on Power SourceMounting the Control BOX Boom or Separated Bench Models Control Cable ConnectionsControl Cable Specifications Available Cable AssembliesElectrode Cable Connections Changing the Wire Drive Ratio Wire Drive Gear Ratio High or LOW SpeedWork Cable Connections Selecting the Proper Gear RatioRatio Change Procedure Setting DIP Switches in the Control BOX DIP Switch SetupLSB Figure A.4 Setting DIP Switches in the Wire DriveProcedure to Install Drive Rolls and Wire Guides Wire Feed Drive Roll KitsGUN and Cable Assemblies with Standard Connection GUN and Cable Assemblies with FAST-MATECONNECTIONMagnum 200 / 300 / 400 Guns General GUN Connection GuidelinesWire Feed Shut Down Circuit Optional Wire Spindle PlacementGmaw Shielding GAS Water Connections for Water Cooled GunsGeneral Panel Installation Guidelines Boom and Bench ConversionsOptional Panels for Control BOX Recommended Processes and Equipment Product DescriptionDuty Cycle Control BOX OperationK1542-14 Head Select Panel K1542-13 Dual Procedure / Memory PanelCV/Gouge PanelStd Control BOX Panels -- ʻLARGEʼ Option PanelsK1542-6 M Panel K1542-11 MX2 PanelK1542-12 MSP2 Panel Control BOX Panels -- SET UP Controls DescriptionControl BOX -- PC Board Adjustments Control BOX -- Using Operating LimitsWire Drive Settings -- External Wire Drive OperationWhen using 2 Step Logic When using 4 Step Logic With Crater Fill OFFWire Reel Loading READI-REELS, Spools or Coils Electrode PolarityGear BOX Ratio Figure B.1 Drive Roll Pressure Setting Feeding Electrode and Brake AdjustmentProcedure for Setting Angle of Feed Plate GAS Guard Regulator SettingWire Reel Changing Wire Feed Overload ProtectionMaking a Weld Status Light States Component Status LightsStatus Light States CONʼT Cored Electrode Wire Size Solid Steel ElectrodeAluminum Electrode Roll DH Drive 4-DrivenDescription and Installation of Optional Control BOX Panels Constant Voltage CV/Weld, CV/MIG, CV/Flux Cored Procedures CC/STICK/GOUGE ModeK1542-11 MX2 Panel Large Panel 10 MS/STT Panel Large Panel K1542-14 Head Select Panel Small Panel K1542-13 Dual Procedure Memory Panel Small PanelK1543, K1544 and K1545 Input Cable Assemblies K1548-1 Linc NET Receptacle KIT Input and Output Feeder Head Enclosure Procedure K1504-1 Coil Adapter K162-1 Wire Spindle Adapter K435 Coil Adapter K363P READI-REEL AdapterGUN Receiver Bushings and Adapters Guns and GUN AdaptersDual Procedure Switch Options Using Dual Procedure with FAST-MATE GunsConduit Adapters K1536-1 Water Flow Sensor KIT K590-6 Water Connection KIT for Drive onlyK659-1 GAS Guard Regulator K1556-1 Light Duty Caster KITWire Drive Motor and Gearbox MaintenanceGun and Cable Maintenance Drive Rolls and Guide TubesHOW to USE Troubleshooting Guide 1TROUBLESHOOTINGE-1Troubleshooting Possible Cause Recommended Symptoms Course of Action Field Service FacilityYour local Lincoln Authorized Troubleshooting Course of Action Possible CauseEither of these fail, the problem is Change Or harness disconnected from Fails the continuity test, repair or Possible Cause Err 003 Err 001Err 004 Err 005Err 100 Err 020Err 200 Err 201Err 212 Err 211Diagrams Control BOX Dimension Print Wire Feeder Bench Model Dimension Print DIAGRAMSF-4 Print Power Feed 10 Dual Precaucion Warnung