Lincoln Electric IM658-A manual Component Status Lights, Status Light States

Page 32

B-11

OPERATION

B-11

 

 

 

COMPONENT STATUS LIGHTS

Each network component has a single status light. The light is a bicolor, Green/Red, LED. The purpose of the status light is to allow the operator to quickly identify that the system is working properly or, if not,

which component is causing the problem. By using the status lights the operator can quickly pinpoint the system problem to a particular component. See the following table for a complete listing and description of all status light conditions.

NOTE: The green light ON and steady indicates a normal functioning system.

STATUS LIGHT STATES

LED State

Power Source LED

LED on any other nodes (components);

 

 

Wire Feeder, Control Box Etc.

 

 

 

Off

Power Source is not turned ON or is not func-

The system component is not receiving input

 

tioning correctly.

power or is faulty.

Green LED blink-

It should only blink for a few seconds while

It should only blink for a few seconds until

ing at a “normal”

the system is mapping (identifying compo-

the system component (node) has been rec-

rate

nents). If blinking continues every group may

ognized. If the blinking continues at least

 

have a mapping error. (DIP switches may be

one node in the group has a mapping error

 

set incorrectly).

(DIP switches may be set incorrectly). The

 

 

node or nodes with mapping errors will be

 

 

blinking red.

 

 

• There may be too many components in the

 

 

group. All components in the group will be

 

 

blinking green.

 

 

• The power source bus may not be avail-

 

 

able. The bus may be being used to program

 

 

another component.

 

 

• The LEDʼs of the power source and the

 

 

component being programmed will be solid

 

 

green.

 

 

 

Red LED blinking

Indicates a recoverable communication fault.

Indicates a recoverable communication fault

at a “normal” rate

The power source should automatically

most likely caused by one of the following.

 

recover: If it cannot recover the LED will be

• More than one control box (UI) in the

 

solid red.

group. All control boxes in the group will be

 

 

blinking red.

 

 

• No control box (UI) in the group. All nodes

 

 

in the group will be blinking red.

 

 

• More than one node, of the same equip-

 

 

ment type, has the same group and feed

 

 

head (FH) numbers. All these nodes will be

 

 

blinking red.

 

 

• The feed head DIP switches may be set to

 

 

zero. The nodes with DIP switches set to

 

 

zero will be blinking red.

 

 

•The node bus may be off.

 

 

 

Red/Green LED

Indicates a recoverable hardware fault such

Indicates a recoverable hardware fault such

blinking at a “nor-

as over temperature, overload shutdown etc.

as over temperature, overload shutdown etc.

mal” rate

 

Could also be an open shutdown circuit at

 

 

the feed head (leads 570, 572 with tab termi-

 

 

nals) typically used for water flow shutdown

 

 

switches.

 

 

 

POWER FEED 10 DUAL

Image 32
Contents OPERATOR’S Manual Safety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents P346 Series Section ESection F Installation Boom Mounting of Wire Drive Unit Safety PrecautionsMounting the Wire Drive Unit Mounting on Power Source Control CableMounting the Control BOX Boom or Separated Bench Models Control Cable ConnectionsElectrode Cable Connections Control Cable SpecificationsAvailable Cable Assemblies Wire Drive Gear Ratio High or LOW Speed Changing the Wire Drive RatioWork Cable Connections Selecting the Proper Gear RatioRatio Change Procedure DIP Switch Setup Setting DIP Switches in the Control BOXLSB Setting DIP Switches in the Wire Drive Figure A.4Wire Feed Drive Roll Kits Procedure to Install Drive Rolls and Wire GuidesGUN and Cable Assemblies with Standard Connection GUN and Cable Assemblies with FAST-MATECONNECTIONGeneral GUN Connection Guidelines Magnum 200 / 300 / 400 GunsWire Spindle Placement Wire Feed Shut Down Circuit OptionalGmaw Shielding GAS Water Connections for Water Cooled GunsOptional Panels for Control BOX General Panel Installation GuidelinesBoom and Bench Conversions Product Description Recommended Processes and EquipmentDuty Cycle Control BOX OperationK1542-13 Dual Procedure / Memory Panel K1542-14 Head Select PanelControl BOX Panels -- ʻLARGEʼ Option Panels CV/Gouge PanelStdK1542-6 M Panel K1542-11 MX2 PanelControl BOX Panels -- SET UP Controls Description K1542-12 MSP2 PanelControl BOX -- Using Operating Limits Control BOX -- PC Board AdjustmentsWire Drive Operation Wire Drive Settings -- ExternalWhen using 2 Step Logic When using 4 Step Logic With Crater Fill OFFGear BOX Ratio Wire Reel Loading READI-REELS, Spools or CoilsElectrode Polarity Figure B.1 Feeding Electrode and Brake Adjustment Drive Roll Pressure SettingProcedure for Setting Angle of Feed Plate GAS Guard Regulator SettingMaking a Weld Wire Reel ChangingWire Feed Overload Protection Component Status Lights Status Light StatesStatus Light States CONʼT Wire Size Solid Steel Electrode Cored ElectrodeAluminum Electrode Roll DH Drive 4-DrivenDescription and Installation of Optional Control BOX Panels CC/STICK/GOUGE Mode Constant Voltage CV/Weld, CV/MIG, CV/Flux Cored ProceduresK1542-11 MX2 Panel Large Panel 10 MS/STT Panel Large Panel K1542-13 Dual Procedure Memory Panel Small Panel K1542-14 Head Select Panel Small PanelK1543, K1544 and K1545 Input Cable Assemblies Feeder Head Enclosure Procedure K1548-1 Linc NET Receptacle KIT Input and OutputK162-1 Wire Spindle Adapter K1504-1 Coil AdapterK435 Coil Adapter K363P READI-REEL AdapterGuns and GUN Adapters GUN Receiver Bushings and AdaptersConduit Adapters Dual Procedure Switch OptionsUsing Dual Procedure with FAST-MATE Guns K590-6 Water Connection KIT for Drive only K1536-1 Water Flow Sensor KITK659-1 GAS Guard Regulator K1556-1 Light Duty Caster KITMaintenance Wire Drive Motor and GearboxGun and Cable Maintenance Drive Rolls and Guide Tubes1TROUBLESHOOTINGE-1 HOW to USE Troubleshooting GuideTroubleshooting Your local Lincoln Authorized Possible Cause Recommended Symptoms Course of ActionField Service Facility Troubleshooting Possible Cause Course of ActionEither of these fail, the problem is Change Or harness disconnected from Fails the continuity test, repair or Possible Cause Err 001 Err 003Err 004 Err 005Err 020 Err 100Err 200 Err 201Err 211 Err 212Diagrams Control BOX Dimension Print Wire Feeder Bench Model Dimension Print DIAGRAMSF-4 Print Power Feed 10 Dual Precaucion Warnung

IM658-A specifications

The Lincoln Electric IM658-A is a highly specialized and versatile industrial welding machine designed to meet the demanding needs of modern fabrication industries. This robust machine stands out for its advanced features and innovative technologies, making it a preferred choice among professionals in various sectors, including manufacturing, automotive, and construction.

One of the notable features of the IM658-A is its extensive range of welding capabilities. It supports several welding processes such as MIG, TIG, and Stick welding. This multifunctionality allows users to tackle a diverse array of projects without the need for multiple machines, simplifying workflow and optimizing efficiency. The machine is engineered to handle various materials, including steel, stainless steel, and aluminum, providing versatility that is crucial for intricate fabrication tasks.

In terms of technology, the Lincoln Electric IM658-A incorporates advanced inverter technology which enhances its performance while minimizing energy consumption. This technology not only reduces the overall weight of the unit but also improves its power efficiency, making it an environmentally friendly choice. The inverter design also contributes to a more stable arc, providing better control and precision during welding processes.

Another significant characteristic of the IM658-A is its user-friendly interface, which boasts an intuitive control panel. This feature is particularly beneficial for operators of varying skill levels, allowing for quick adjustments to settings and ensuring optimal performance for different welding tasks. The digital display aids in easy monitoring of parameters, resulting in consistent weld quality.

Durability is a hallmark of the Lincoln Electric brand, and the IM658-A is no exception. Constructed with high-quality materials, the machine is built to withstand the rigors of industrial environments. Its robust design includes protective features that safeguard internal components from damage, ensuring longevity and reliability.

Moreover, the machine is designed with portability in mind, as it is relatively lightweight and includes ergonomic handles, facilitating easy transportation around job sites. This makes it an ideal choice for mobile welding applications where versatility and ease of movement are crucial.

In summary, the Lincoln Electric IM658-A combines advanced features with innovative technologies to deliver a welding solution that meets the rigorous demands of various industries. Its multifunctional capabilities, energy-efficient design, user-friendly interface, and durable build make it a standout option for professionals looking to enhance their welding operations.