Lincoln Electric IM528-B manual Electric Shock can kill

Page 3

ii

SAFETY

ii

ELECTRIC SHOCK can kill.

3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free gloves to insulate hands.

3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.

In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:

Semiautomatic DC Constant Voltage (Wire) Welder.

DC Manual (Stick) Welder.

AC Welder with Reduced Voltage Control.

3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically “hot”.

3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.

3.e. Ground the work or metal to be welded to a good electrical (earth) ground.

3.f. Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.

3.g. Never dip the electrode in water for cooling.

3.h. Never simultaneously touch electrically “hot” parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.

3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.

3.j. Also see Items 6.c. and 8.

ARC RAYS can burn.

4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.

4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.

4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.

FUMES AND GASES can be dangerous.

5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases.When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep

fumes and gases away from the breathing zone. When

welding with electrodes which require special ventilation such as stainless or hard facing (see instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and below Threshold Limit Values (TLV) using local exhaust or mechanical ventilation. In confined spaces or in some circumstances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.

5.b. Do not weld in locations near chlorinated hydrocarbon vapors coming from degreasing, cleaning or spraying operations.

The heat and rays of the arc can react with solvent vapors to form phosgene, a highly toxic gas, and other irritating products.

5.c. Shielding gases used for arc welding can displace air and cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.

5.d. Read and understand the manufacturer’s instructions for this equipment and the consumables to be used, including the material safety data sheet (MSDS) and follow your employer’s safety practices. MSDS forms are available from your welding distributor or from the manufacturer.

5.e. Also see item 1.b.

Mar ‘95

- ii -

TIG MODULE

Image 3
Contents TIG Module Safety Electric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Technical Specifications TIG Module InstallationHigh Frequency Interference Protection Safety PrecautionsLocation Environmental ProtectionInput and Output Connections Supply ConnectionsInstallation of Field Installed Accessories Ranger 8 Installation Installation with a Power SourceRanger 8 / TIG Module Connection Diagram Installation Ranger 8 / K892-1 Remote KIT / TIG Module Connection Diagram Ranger 9 Installation Ranger 9 and the TIG Module Required EquipmentRanger 9 and the TIG Module Optional Equipment Ranger 9 / TIG Module Connection Diagram Ranger 10 and Ranger 300 D Installation Ranger 10 / TIG Module Connection Diagram Ranger 300 D / TIG Module Connection Diagram 12b Ranger 10-LX and Ranger 300D-LX Installation Ranger 10-LX / TIG Module Connection Diagram Ranger 300D-LX / TIG Module Connection Diagram 14b Switch Classic Classic III & Iiid Idealarc 250 AC/DC Installation with other Lincoln Power SourcesInstallation TIG Module on a Lincoln Power Source Connection Diagram General Warnings Operating InstructionsGAS Input Graphic Symbols Used on this Equipment or in this ManualProduct Description Recommended Processes and EquipmentDesign Summary Control Panel OperationRear Connections Ranger 8 Operation K930- / Ranger 8 Without the K892-1 SettingsK930- Settings Ranger 8 Without the K892-1 Remote KIT SettingsRanger 8 with the K892-1 Remote KIT Installed Settings K930- / Ranger 8 with the K892-1 SettingsTIG Module Settings Ranger 9 Operation K930- / Ranger 9 SettingsRanger 10 / Ranger 300 D Operation Ranger 10 SettingsRanger 10-LX / Ranger 300 DLX Operation Ranger 10-LX SettingsOperation on Other Lincoln Power Sources K930- / Lincoln Power Source SettingsLincoln Power Source Settings Typical Current Ranges 1 for Tungsten Electrodes TIG Welding InformationOptions / Accessories Periodic Maintenance Safety PrecautionsHow To Use Troubleshooting Guide TroubleshootingTroubleshooting Guide Problems Possible Symptoms CauseRecommended Course of Action Output Problems Course of Action IRECOMMENDEDTIG Module Wiring DiagramWiring Diagram for Code Page Page Precaucion Guards off