Lincoln Electric IM528-B manual Ranger 10 / TIG Module Connection Diagram

Page 19

FIGURE 4: RANGER 10 / TIG MODULE CONNECTION DIAGRAM

WARNING

Do not operate with panels open.

Disconnect NEGATIVE (-) BATTERY LEAD before servicing.

Do not touch electrically live parts.

REGULATOR

FLOWMETER

Keep guards in place.

Keep away from moving parts.

Only qualified personnel should install,use or service this equipment.

12

TIG

ARGON GAS

TO GAS

CYLINDER

INPUT

FITTING

A T12246 BYPASS CAPACITOR ASBLY. MUST BE INSTALLED IN THE RANGER 10 TO PROTECT THE RANGER 10 FROM DAMAGE.

WELDING CABLES MUST BE PROPERLY SIZED FOR THE CURRENT AND DUTY CYCLE OF APPLICATION.

 

O

 

 

 

 

HF

 

 

CURRENT

POWER

HIGH FREQUENCY

AFTERFLOW

CURRENT CONTROL

CONTROL

 

 

 

 

SWITCH

LINCOLN

 

 

 

ELECTRIC

 

 

WARNING

E F

K870 FOOT AMPTROL

-OR-

K963 HAND AMPTROL

-OR-

K814 ARC START SWITCH

INSTALLATION

MODULE

11/96

M17533

NOTE: This diagram is for reference only. It was accurate at the time of printing , however Lincoln Electric reserves the right to make improvements and modifications as necessary, if you supect this information to be inaccurate, write to the Service Department for a replacement. Give the equipment code number..

Image 19
Contents TIG Module Safety Electric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Technical Specifications TIG Module InstallationHigh Frequency Interference Protection Safety PrecautionsLocation Environmental ProtectionInput and Output Connections Supply ConnectionsInstallation of Field Installed Accessories Ranger 8 Installation Installation with a Power SourceRanger 8 / TIG Module Connection Diagram Installation Ranger 8 / K892-1 Remote KIT / TIG Module Connection Diagram Ranger 9 and the TIG Module Required Equipment Ranger 9 Installation Ranger 9 and the TIG Module Optional Equipment Ranger 9 / TIG Module Connection Diagram Ranger 10 and Ranger 300 D Installation Ranger 10 / TIG Module Connection Diagram Ranger 300 D / TIG Module Connection Diagram 12b Ranger 10-LX and Ranger 300D-LX Installation Ranger 10-LX / TIG Module Connection Diagram Ranger 300D-LX / TIG Module Connection Diagram 14b Switch Classic Classic III & Iiid Idealarc 250 AC/DC Installation with other Lincoln Power SourcesInstallation TIG Module on a Lincoln Power Source Connection Diagram General Warnings Operating InstructionsGAS Input Graphic Symbols Used on this Equipment or in this ManualRecommended Processes and Equipment Product DescriptionDesign Summary Control Panel OperationRear Connections Ranger 8 Operation K930- / Ranger 8 Without the K892-1 SettingsK930- Settings Ranger 8 Without the K892-1 Remote KIT SettingsRanger 8 with the K892-1 Remote KIT Installed Settings K930- / Ranger 8 with the K892-1 SettingsTIG Module Settings Ranger 9 Operation K930- / Ranger 9 SettingsRanger 10 / Ranger 300 D Operation Ranger 10 SettingsRanger 10-LX / Ranger 300 DLX Operation Ranger 10-LX SettingsK930- / Lincoln Power Source Settings Operation on Other Lincoln Power SourcesLincoln Power Source Settings Typical Current Ranges 1 for Tungsten Electrodes TIG Welding InformationOptions / Accessories Periodic Maintenance Safety PrecautionsHow To Use Troubleshooting Guide TroubleshootingProblems Possible Symptoms Cause Troubleshooting GuideRecommended Course of Action Output Problems Course of Action IRECOMMENDEDTIG Module Wiring DiagramWiring Diagram for Code Page Page Precaucion Guards off