Lincoln Electric IM528-B manual TIG Module on a Lincoln Power Source Connection Diagram

Page 28

TIG MODULE

FIGURE 6: TIG MODULE ON A LINCOLN POWER SOURCE - CONNECTION DIAGRAM

WARNING

Do not operate with panels open.

Disconnect NEGATIVE (-) BATTERY LEAD or input power before servicing.

Do not touch electrically live parts.

REGULATOR

FLOWMETER

Keep guards in place.

Keep away from moving parts.

Only qualified personnel should install,use or service this equipment.

17

ARGON GAS

TO GAS

CYLINDER

INPUT

 

 

FITTING

K936-[ ] CONTROL CABLE

TO GROUNDED 115VAC SUPPLY (IF PRESENT)

TO 6-PIN OR 14-PIN MS-CONNECTOR OR TERMINAL STRIP (IF PRESENT)

 

O

 

 

 

 

HF

 

 

CURRENT

POWER

HIGH FREQUENCY

AFTERFLOW

CURRENT CONTROL

CONTROL

 

 

 

 

SWITCH

LINCOLN

 

 

 

ELECTRIC

 

 

WARNING

K870 FOOT AMPTROL

-OR-

K963 HAND AMPTROL

-OR-

TO POWER SOURCE WORK TERMINAL K814 ARC START SWITCH

TO POWER SOURCE ELECTRODE TERMINAL

INSTALLATION

WELDING CABLES MUST BE PROPERLY SIZED FOR

THE CURRENT AND DUTY CYCLE OF APPLICATION

4-19-96D

M17608

NOTE: This diagram is for reference only. It was accurate at the time of printing , however Lincoln Electric reserves the right to make improvements and modifications as necessary, if you supect this information to be inaccurate, write to the Service Department for a replacement. Give the equipment code number..

Image 28
Contents TIG Module Safety Electric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Installation Technical Specifications TIG ModuleSafety Precautions LocationEnvironmental Protection High Frequency Interference ProtectionSupply Connections Input and Output ConnectionsInstallation of Field Installed Accessories Installation with a Power Source Ranger 8 InstallationRanger 8 / TIG Module Connection Diagram Installation Ranger 8 / K892-1 Remote KIT / TIG Module Connection Diagram Ranger 9 and the TIG Module Required Equipment Ranger 9 InstallationRanger 9 and the TIG Module Optional Equipment Ranger 9 / TIG Module Connection Diagram Ranger 10 and Ranger 300 D Installation Ranger 10 / TIG Module Connection Diagram Ranger 300 D / TIG Module Connection Diagram 12b Ranger 10-LX and Ranger 300D-LX Installation Ranger 10-LX / TIG Module Connection Diagram Ranger 300D-LX / TIG Module Connection Diagram 14b Installation with other Lincoln Power Sources Switch Classic Classic III & Iiid Idealarc 250 AC/DCInstallation TIG Module on a Lincoln Power Source Connection Diagram Operating Instructions General WarningsGraphic Symbols Used on this Equipment or in this Manual GAS InputRecommended Processes and Equipment Product DescriptionDesign Summary Operation Control PanelRear Connections K930- / Ranger 8 Without the K892-1 Settings K930- SettingsRanger 8 Without the K892-1 Remote KIT Settings Ranger 8 OperationK930- / Ranger 8 with the K892-1 Settings Ranger 8 with the K892-1 Remote KIT Installed SettingsTIG Module Settings K930- / Ranger 9 Settings Ranger 9 OperationRanger 10 Settings Ranger 10 / Ranger 300 D OperationRanger 10-LX Settings Ranger 10-LX / Ranger 300 DLX OperationK930- / Lincoln Power Source Settings Operation on Other Lincoln Power SourcesLincoln Power Source Settings TIG Welding Information Typical Current Ranges 1 for Tungsten ElectrodesOptions / Accessories Safety Precautions Periodic MaintenanceTroubleshooting How To Use Troubleshooting GuideProblems Possible Symptoms Cause Troubleshooting GuideRecommended Course of Action Output Problems IRECOMMENDED Course of ActionWiring Diagram TIG ModuleWiring Diagram for Code Page Page Precaucion Guards off