Lincoln Electric IM528-B manual Irecommended, Course of Action

Page 47

TROUBLESHOOTING

Troubleshooting Guide

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

POSSIBLE

(SYMPTOMS)

CAUSE

 

HIGH FREQUENCY PROBLEMS

High frequency not present or

1.

Check for correct gas and gas

intermittent at torch electrode

 

flow

 

2.

Check torch and work cables

 

 

for breaks and leaks

 

3.

Check spark gap for correct

 

 

setting 0.015in. (.25mm)

High frequency not present at spark 1.

Make certain that the High

gap

Frequency switch (S2) is NOT

 

in the OFF position

2.

Check spark gap for correct

 

setting 0.015in (.25mm)

iRECOMMENDED

COURSE OF ACTION

If all recommended possible areas of misadjustment have been checked and the problem persists,

Contact your local Lincoln Authorized Field Service Facility.

High Frequency stays on after the arc is established

1.High frequency switch (S2) is in the continuous position

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

36

TIG MODULE

Image 47
Contents TIG Module Safety Electric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Technical Specifications TIG Module InstallationHigh Frequency Interference Protection Safety PrecautionsLocation Environmental ProtectionInput and Output Connections Supply ConnectionsInstallation of Field Installed Accessories Ranger 8 Installation Installation with a Power SourceRanger 8 / TIG Module Connection Diagram Installation Ranger 8 / K892-1 Remote KIT / TIG Module Connection Diagram Ranger 9 and the TIG Module Optional Equipment Ranger 9 InstallationRanger 9 and the TIG Module Required Equipment Ranger 9 / TIG Module Connection Diagram Ranger 10 and Ranger 300 D Installation Ranger 10 / TIG Module Connection Diagram Ranger 300 D / TIG Module Connection Diagram 12b Ranger 10-LX and Ranger 300D-LX Installation Ranger 10-LX / TIG Module Connection Diagram Ranger 300D-LX / TIG Module Connection Diagram 14b Switch Classic Classic III & Iiid Idealarc 250 AC/DC Installation with other Lincoln Power SourcesInstallation TIG Module on a Lincoln Power Source Connection Diagram General Warnings Operating InstructionsGAS Input Graphic Symbols Used on this Equipment or in this ManualDesign Summary Product DescriptionRecommended Processes and Equipment Control Panel OperationRear Connections Ranger 8 Operation K930- / Ranger 8 Without the K892-1 SettingsK930- Settings Ranger 8 Without the K892-1 Remote KIT SettingsRanger 8 with the K892-1 Remote KIT Installed Settings K930- / Ranger 8 with the K892-1 SettingsTIG Module Settings Ranger 9 Operation K930- / Ranger 9 SettingsRanger 10 / Ranger 300 D Operation Ranger 10 SettingsRanger 10-LX / Ranger 300 DLX Operation Ranger 10-LX SettingsLincoln Power Source Settings Operation on Other Lincoln Power SourcesK930- / Lincoln Power Source Settings Typical Current Ranges 1 for Tungsten Electrodes TIG Welding InformationOptions / Accessories Periodic Maintenance Safety PrecautionsHow To Use Troubleshooting Guide TroubleshootingRecommended Course of Action Troubleshooting GuideProblems Possible Symptoms Cause Output Problems Course of Action IRECOMMENDEDTIG Module Wiring DiagramWiring Diagram for Code Page Page Precaucion Guards off