Lincoln Electric IM528-B manual Output Problems

Page 46

TROUBLESHOOTING

Observe Safety Guidelines

detailed in the beginning of this manual.

Troubleshooting Guide

PROBLEMS

POSSIBLE

(SYMPTOMS)

CAUSE

 

OUTPUT PROBLEMS

No weld output, no gas flow and no

1. Check arc start switch or

high frequency at spark gap

remote control unit

 

2. Make certain both the TIG

 

Module and the welding power

 

source are powered up

Low weld output current when 1.

Make certain the welder power

operating in remote control

source is in the remote control

 

mode

2.

The current control (R4) may

 

be set too low for the process

RECOMMENDED COURSE OF ACTION

If all recommended possible areas of misadjustment have been checked and the problem persists,

Contact your local Lincoln Authorized Field Service Facility.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

TIG MODULE

35

Image 46
Contents TIG Module Safety Electric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Installation Technical Specifications TIG ModuleEnvironmental Protection Safety PrecautionsLocation High Frequency Interference ProtectionSupply Connections Input and Output ConnectionsInstallation of Field Installed Accessories Installation with a Power Source Ranger 8 InstallationRanger 8 / TIG Module Connection Diagram Installation Ranger 8 / K892-1 Remote KIT / TIG Module Connection Diagram Ranger 9 and the TIG Module Required Equipment Ranger 9 InstallationRanger 9 and the TIG Module Optional Equipment Ranger 9 / TIG Module Connection Diagram Ranger 10 and Ranger 300 D Installation Ranger 10 / TIG Module Connection Diagram Ranger 300 D / TIG Module Connection Diagram 12b Ranger 10-LX and Ranger 300D-LX Installation Ranger 10-LX / TIG Module Connection Diagram Ranger 300D-LX / TIG Module Connection Diagram 14b Installation with other Lincoln Power Sources Switch Classic Classic III & Iiid Idealarc 250 AC/DCInstallation TIG Module on a Lincoln Power Source Connection Diagram Operating Instructions General WarningsGraphic Symbols Used on this Equipment or in this Manual GAS InputRecommended Processes and Equipment Product DescriptionDesign Summary Operation Control PanelRear Connections Ranger 8 Without the K892-1 Remote KIT Settings K930- / Ranger 8 Without the K892-1 SettingsK930- Settings Ranger 8 OperationK930- / Ranger 8 with the K892-1 Settings Ranger 8 with the K892-1 Remote KIT Installed SettingsTIG Module Settings K930- / Ranger 9 Settings Ranger 9 OperationRanger 10 Settings Ranger 10 / Ranger 300 D OperationRanger 10-LX Settings Ranger 10-LX / Ranger 300 DLX OperationK930- / Lincoln Power Source Settings Operation on Other Lincoln Power SourcesLincoln Power Source Settings TIG Welding Information Typical Current Ranges 1 for Tungsten ElectrodesOptions / Accessories Safety Precautions Periodic MaintenanceTroubleshooting How To Use Troubleshooting GuideProblems Possible Symptoms Cause Troubleshooting GuideRecommended Course of Action Output Problems IRECOMMENDED Course of ActionWiring Diagram TIG ModuleWiring Diagram for Code Page Page Precaucion Guards off