Lincoln Electric IM528-B manual Options / Accessories

Page 42

ACCESSORIES

OPTIONS / ACCESSORIES

The following field installed Kits and accessories may be used dependingon the application:

K936 Control Cables

At least one of the following control cables is needed to connect the TIG Module to the power source. Four different cables are available. The proper choice of cable depends on the power source being used. See the installation section to choose the proper control cable. The control cable carries one or more of the following circuits between the TIG Module and the power source: Input power, remote control signals, contactor control signals, and ground.

K936-19-Socket (at the TIG Module) to 14-pin (at the power source) (Contains circuits 2, 4, 31, 32, 75, 76, 77 and ground)

K936-39-Socket to a grounded 115V plug and a 6-pin MS-connector (Contains circuits 31, 32, 75, 76, 77 and ground)

K936-49-Socket to a grounded 115V plug (Contains circuits 31, 32 and ground.)

K937 Control Cables Extensions

Control cable extensions are available in 22 and 45 foot engths. These allow the TIG Module to be operated at distances up to 200 feet from the power source. The extensions connect between the standard control cable and the TIG Module.

K937-2222 foot extension cable, 9-Socket to 9-pin

K937-4545 foot extension cable, 9-Socket to 9-pin

K938-1 Contactor Kit

This field installed kit must be installed in the TIG Module whenever it is used with a power source which does not have a built-in contactor for constant current (stick/TIG) welding. See the list of compatible power sources to see which applications require the Contactor Kit.

K844-1 Water Valve Kit

A field installed kit which contains one water valve for mounting inside the TIG Module. The water valve is controlled by the same preflow and afterflow timers as the gas valve.

Other Compatible Lincoln Accessories:

K963 Hand Amptrol

K870 Foot Amptrol

K814 Arc Start Switch

All Magnum TIG torches and accessories

Compatible Equipment

The TIG Module can be used with the following Lincoln power sources:

Ranger 81

Ranger 9

Ranger 101

Ranger 10-LX1

DC-250

DC-400

DC-600

DC-650Pro/DC-750

R3R-300/400/500,

including Iversions1

Idealarc 250 AC/DC1

Weldanpower 1501

Weldanpower 150 AC/DC1

Weldanpower G80001

SA 250 Perkins1

SAE 350 Deutz1

SAE 4001

Classic I1,2

Classic II1

Classic III & IIID1

1Requires the K938-1 Contactor Kit in the TIG Module 2Requires a source of 115VAC power

For installation of field installed accessories see the

INSTALLATION SECTION.

K939-1 Docking Kit

The Docking Kit provides a means to dockthe TIG Module on top of a flat-roofed power source, or any other flat surface measuring at least 10 X 15 inches (255 X 381 mm). It includes a latch and provisions for a user-supplied padlock to lock the TIG Module in place.

TIG MODULE

31

Image 42
Contents TIG Module Safety Electric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Installation Technical Specifications TIG ModuleEnvironmental Protection Safety PrecautionsLocation High Frequency Interference ProtectionSupply Connections Input and Output ConnectionsInstallation of Field Installed Accessories Installation with a Power Source Ranger 8 InstallationRanger 8 / TIG Module Connection Diagram Installation Ranger 8 / K892-1 Remote KIT / TIG Module Connection Diagram Ranger 9 Installation Ranger 9 and the TIG Module Required EquipmentRanger 9 and the TIG Module Optional Equipment Ranger 9 / TIG Module Connection Diagram Ranger 10 and Ranger 300 D Installation Ranger 10 / TIG Module Connection Diagram Ranger 300 D / TIG Module Connection Diagram 12b Ranger 10-LX and Ranger 300D-LX Installation Ranger 10-LX / TIG Module Connection Diagram Ranger 300D-LX / TIG Module Connection Diagram 14b Installation with other Lincoln Power Sources Switch Classic Classic III & Iiid Idealarc 250 AC/DCInstallation TIG Module on a Lincoln Power Source Connection Diagram Operating Instructions General WarningsGraphic Symbols Used on this Equipment or in this Manual GAS InputProduct Description Recommended Processes and EquipmentDesign Summary Operation Control PanelRear Connections Ranger 8 Without the K892-1 Remote KIT Settings K930- / Ranger 8 Without the K892-1 SettingsK930- Settings Ranger 8 OperationK930- / Ranger 8 with the K892-1 Settings Ranger 8 with the K892-1 Remote KIT Installed SettingsTIG Module Settings K930- / Ranger 9 Settings Ranger 9 OperationRanger 10 Settings Ranger 10 / Ranger 300 D Operation Ranger 10-LX Settings Ranger 10-LX / Ranger 300 DLX OperationOperation on Other Lincoln Power Sources K930- / Lincoln Power Source SettingsLincoln Power Source Settings TIG Welding Information Typical Current Ranges 1 for Tungsten ElectrodesOptions / Accessories Safety Precautions Periodic MaintenanceTroubleshooting How To Use Troubleshooting GuideTroubleshooting Guide Problems Possible Symptoms CauseRecommended Course of Action Output Problems IRECOMMENDED Course of ActionWiring Diagram TIG ModuleWiring Diagram for Code Page Page Precaucion Guards off