Friedrich MR12C1H, MW12C1H, MW09C1H, MR09C1H manual

Page 11

Specifications

Outdoor Unit

 

 

 

MR12C1H

 

Manufacturer/trademark

 

 

SANYO

 

 

 

 

 

 

 

Model

 

 

C-6RZ110H1A

 

 

 

 

 

 

 

Type

 

 

Twin rotory

Compressor

 

 

 

 

 

L.R.A. (A)

A

33

 

 

 

 

 

 

 

 

RLA(A)

A

4.59

 

 

 

 

 

 

 

 

Power Input(W)

W

800

 

 

 

 

 

 

 

 

Overload Protector

 

 

Int11l-3979

 

 

 

 

 

 

Throttling Method

 

Electronic Expansion Valve

 

 

throttling

 

 

 

 

 

 

 

 

 

 

Starting Method

 

 

Transducer starting

 

 

 

 

 

 

Working Temp Range

F

41 - 115

 

 

 

 

 

 

 

Heat

Coil

 

 

Aluminum fin-copper tube

Exchanger

 

 

 

 

 

Pipe Diameter

mm

.275

 

Coil

 

 

 

 

 

 

Rows-Fin Gap

in.

2 - .005

 

 

 

 

 

 

 

 

 

Coil length (l) x height (H) x coil width (L)

mm

 

747X508X44

 

 

 

 

 

 

 

Speed

rpm

900/680

 

 

 

 

 

 

 

Fan Motor

Output of Fan Motor

W

40

 

 

 

 

 

 

RLA

A

0.17

 

 

 

 

 

 

 

 

 

 

Capacitor

F

/

 

 

 

 

 

 

 

Air Flow Volume of Outdoor Unit

CFM

1118

 

 

 

 

 

 

 

Fan

Type-Piece

 

 

Axial fan

 

 

 

 

 

Diameter

in.

15.7

 

 

 

 

 

 

 

 

 

Defrosting Method

 

/

 

 

 

 

 

 

 

Climate Type

 

 

 

T1

 

 

 

 

 

 

Isolation

 

 

 

I

 

 

 

 

 

Moisture Protection

 

 

IP24

 

 

 

 

 

Permissible Excessive Operating

PSI

552

 

Pressure for the Discharge Side

 

 

 

 

 

Permissible Excessive Operating

PSI

175

 

Pressure for the Suction Side

 

 

 

 

 

 

 

 

 

 

Sound Pressure Level

dB (A)

55

 

Sound Power Level

dB (A)

65

 

Dimension (W×H×D)

in.

 

 

33 3/8 X 23 1/2 X 12 1/2

 

 

 

 

 

 

 

Dimension of Package (L×W×H)

in.

 

34.6 X 14.2 X 22.3

 

 

 

 

 

Net Weight /Gross Weight

lbs

79.4/90.4

 

 

 

 

 

 

 

Refrigerant

Name of refrigerant

 

 

R410A

 

 

 

 

 

Weight

lbs

2.65

 

 

 

 

Factory Prescharge

ft

25

 

 

 

 

 

 

 

Connection

Gas additional charge

H

 

1/4 oz per ft

Pipe

 

 

 

 

 

Liquid Pipe Diameter

mm

 

Φ6(1/4”)

 

 

 

 

 

 

 

Gas Pipe Diameter

mm

 

Φ9(3/8”)

 

 

 

 

 

 

Max. Interunit Height Difference

ft

33

 

 

 

 

 

 

Max. Interunit Piping Length

ft

66

 

 

 

 

 

 

 

The above data is subject to change without notice. Please refer to the nameplate of the unit.

11

Image 11
Contents Split Type Room AIR Conditioner Wall Mounted Type Table of Contents Model and product code Summary and features Important Safety Information Refrigeration System Repair Hazards Property Damage Hazards Specifications 115 MR09C1H MR12C1H Appending date Expanded capacity data tables for both cooling and heating Operation Characteristic Curve 09KUnits Construction Views Refrigerant System Diagram Electrical Date Electrical wiringCooling Models TOP View Bottom View Bottom View Function and Control Remote Control OperationsAuto Timer on Displayed. If the light is tunrned off Disappears Replacement of Batteries Description of Each Control Operation Function and Control Function and Control Setting+ 2, medium speed Tring ≤ Tsetting 2, low speed P2 Maximum cooling and heating Compressor Protection Function Detection of temperature sensor malfunctionFrequency Control 3-minutes StandbyFreeze-up Protection Control Discharge Pipe ControlInput Current Control Detail Conditions for Start Controlling Tap Control in indoor/outdoor unit silent operation Fan ControlImportant Notices Ground requirements Installation dimension diagram Boring Piping Hole Installing Indoor Unit Installing Outdoor Unit Electric wiringCheck after Installation and Operation Test Check after InstallationInstallation of Healthy Filter Installation and Maintenance of Healthy FilterOptionalTroubleshooting Can not start up Malfunction of four-way valve Is not on, then replace the protector Adjust support washer of compressor, Troubleshooting YELLOW-LED4 GREEN-LED2 RED-LED3 Analysis or processing of some of the malfunction display How to Check simply the main part Troubleshooting Comp Page AP1 Troubleshooting Is stop time of the compressor longer than 3 minutes? Minutes after the complete unit is powered off Start If the fault is eliminated? Troubleshooting Flow chart for outdoor communitcation circuit detecting Troubleshooting Guide Troubleshooting Guide Temp Resistance Way Valve Liquid Side 2-way, 3-way Valve AppearanceProcedure Close Close Open Close Balance Refrigerant of the 3-way Valve Evacuation ProcedureAfter Evacuation Gas ChargingRemoval Procedure Removal Procedure Removal Procedure Removal Procedure of Outdoor Unit Removal Procedure Removal Procedure MW09C1H / MW12C1H Exploded Diagram MW09C1H Parts List MW12C1H Parts List MR09C1H Exploded Diagram MR09C1H Parts List MR12C1H Exploded View MR12C1H Parts List Page Friedrich AIR Conditioning CO