Friedrich MR09C1H, MW12C1H, MW09C1H, MR12C1H manual Check after Installation and Operation Test

Page 42

INSTALLATION MANUAL

7.5 Check after Installation and Operation Test

Check after Installation

Items to be checked

Possible malfunction

 

 

Has it been fixed firmly?

The unit may drop, shake or emit noise.

 

 

Have you done the refrigerant leakage test?

It may cause insufficient cooling(heating)

capacity

 

 

 

Is heat insulation sufficient?

It may cause condensation and dripping.

 

 

Is water drainage satisfactory?

It may cause condensation and dripping.

 

 

Is the voltage in accordance with the rated

It may cause electric malfunction

 

voltage marked on the nameplate?

or damage the product.

 

 

Is the electric wiring and piping

It may cause electric malfunction

connection installed correctly and securely?

or damage the part.

Has the unit been connected to a secure

It may cause electrical leakage.

ground connection?

 

Is the power cord specified?

It may cause electric malfunction

or damage the part.

 

Are the inlet and outlet openings blocked?

It may cause insufficient cooling(heating)

 

capacity.

 

 

Is the length of connection pipes

The refrigerant capacity is not accurate.

and refrigerant capacity been recorded?

 

 

 

Operation Test

Before Operation Test

Do not switch on power before installation is finished completely.

Electric wiring must be connected correctly and securely.

Cut-off valves of the connection pipes should be opened.

All the impurities such as scraps and thrums must be cleared from the unit.

Operation Test Method

Switch on power and press "ON/OFF" button on the wireless remote controller to start the operation.

Press MODE button to select the COOL, HEAT (Cooling only unit is not available), FAN to check whether the operation is normal or not.

42

Image 42
Contents Split Type Room AIR Conditioner Wall Mounted Type Table of Contents Model and product code Summary and features Important Safety Information Refrigeration System Repair Hazards Property Damage Hazards Specifications 115 MR09C1H MR12C1H Appending date Expanded capacity data tables for both cooling and heating Operation Characteristic Curve 09KUnits Construction Views Refrigerant System Diagram Electrical wiring Electrical DateCooling Models TOP View Bottom View Bottom View Remote Control Operations Function and ControlAuto Timer on Displayed. If the light is tunrned off Disappears Replacement of Batteries Description of Each Control Operation Function and Control Function and Control Setting+ 2, medium speed Tring ≤ Tsetting 2, low speed P2 Maximum cooling and heating 3-minutes Standby Detection of temperature sensor malfunctionFrequency Control Compressor Protection FunctionDischarge Pipe Control Input Current ControlFreeze-up Protection Control Detail Conditions for Start Controlling Fan Control Tap Control in indoor/outdoor unit silent operationImportant Notices Ground requirements Installation dimension diagram Boring Piping Hole Installing Indoor Unit Electric wiring Installing Outdoor UnitCheck after Installation Check after Installation and Operation TestInstallation and Maintenance of Healthy FilterOptional Installation of Healthy FilterTroubleshooting Can not start up Malfunction of four-way valve Is not on, then replace the protector Adjust support washer of compressor, Troubleshooting YELLOW-LED4 GREEN-LED2 RED-LED3 Analysis or processing of some of the malfunction display How to Check simply the main part Troubleshooting Comp Page AP1 Troubleshooting Is stop time of the compressor longer than 3 minutes? Minutes after the complete unit is powered off Start If the fault is eliminated? Troubleshooting Flow chart for outdoor communitcation circuit detecting Troubleshooting Guide Troubleshooting Guide Temp Resistance 2-way, 3-way Valve Appearance Way Valve Liquid SideProcedure Close Close Open Close Balance Refrigerant of the 3-way Valve Procedure EvacuationGas Charging After EvacuationRemoval Procedure Removal Procedure Removal Procedure Removal Procedure of Outdoor Unit Removal Procedure Removal Procedure MW09C1H / MW12C1H Exploded Diagram MW09C1H Parts List MW12C1H Parts List MR09C1H Exploded Diagram MR09C1H Parts List MR12C1H Exploded View MR12C1H Parts List Page Friedrich AIR Conditioning CO