Friedrich MW12C1H, MR09C1H, MR12C1H manual MW09C1H Parts List

Page 81

MW09C1H Parts List

NO.

FPN Part Description

169700100 Filter Sub-Assy

269700101 Front Case Sub-Assy

369700102 Front Case

469700103 Evaporator Assy

569700104 Evaporator Support

669700105 Guide Louver

769700106 Axile Bush (guide louver)

869700107 Rear Grill

969700108 Helicoid tongue

1069700109 Air Louver 2

1169700110 Air Louver 1

1269700111 Left Axile Bush

1369700112 Bearing cushion rubber base

1469700113 O-Gasket sub-assy of Bearing

1569700114 Cross Flow Fan

1669700115 Water Tray Glue Plug

1769700116 Wall Mounting Frame

1869700117 MotorPressPlate

1969700118 Pipe Clamp

2069700119 Drainage Pipe

2169700120 Cable Cross Plate

2269700121 Rear Case assy

2369700122 Fan Motor

2469700123 Motor MP24AA

2569700124 Crank

2669700125 Display Board

2769700126 Ambient Temperature Sensor

2869700127 Transformer

2969700128 Electric Box Assy

3069700129 Electric Box

3169700130 4-bit Terminal Board

3269700131 Main Board

3369700132 Jumping Connector

3469700133 Tube Sensor (20K black)

3569700134 Electric Box Cover1

3669700135 Shield cover of Electric Box sub-assy

3769700136 Remote Control

3869700137 Electric Box Cover2

3969700138 Screw Cover

4069700139 Front panel D1

4169700140 Front Panel Sub-Assy

81

Image 81
Contents Split Type Room AIR Conditioner Wall Mounted Type Table of Contents Model and product code Summary and features Important Safety Information Refrigeration System Repair Hazards Property Damage Hazards Specifications 115 MR09C1H MR12C1H Appending date Expanded capacity data tables for both cooling and heating Operation Characteristic Curve 09KUnits Construction Views Refrigerant System Diagram Electrical Date Electrical wiringCooling Models TOP View Bottom View Bottom View Function and Control Remote Control OperationsAuto Timer on Displayed. If the light is tunrned off Disappears Replacement of Batteries Description of Each Control Operation Function and Control Function and Control Setting+ 2, medium speed Tring ≤ Tsetting 2, low speed P2 Maximum cooling and heating Frequency Control Detection of temperature sensor malfunction3-minutes Standby Compressor Protection FunctionDischarge Pipe Control Input Current ControlFreeze-up Protection Control Detail Conditions for Start Controlling Tap Control in indoor/outdoor unit silent operation Fan ControlImportant Notices Ground requirements Installation dimension diagram Boring Piping Hole Installing Indoor Unit Installing Outdoor Unit Electric wiringCheck after Installation and Operation Test Check after InstallationInstallation of Healthy Filter Installation and Maintenance of Healthy FilterOptionalTroubleshooting Can not start up Malfunction of four-way valve Is not on, then replace the protector Adjust support washer of compressor, Troubleshooting YELLOW-LED4 GREEN-LED2 RED-LED3 Analysis or processing of some of the malfunction display How to Check simply the main part Troubleshooting Comp Page AP1 Troubleshooting Is stop time of the compressor longer than 3 minutes? Minutes after the complete unit is powered off Start If the fault is eliminated? Troubleshooting Flow chart for outdoor communitcation circuit detecting Troubleshooting Guide Troubleshooting Guide Temp Resistance Way Valve Liquid Side 2-way, 3-way Valve AppearanceProcedure Close Close Open Close Balance Refrigerant of the 3-way Valve Evacuation ProcedureAfter Evacuation Gas ChargingRemoval Procedure Removal Procedure Removal Procedure Removal Procedure of Outdoor Unit Removal Procedure Removal Procedure MW09C1H / MW12C1H Exploded Diagram MW09C1H Parts List MW12C1H Parts List MR09C1H Exploded Diagram MR09C1H Parts List MR12C1H Exploded View MR12C1H Parts List Page Friedrich AIR Conditioning CO