Friedrich MR09C1H, MW12C1H, MW09C1H, MR12C1H manual YELLOW-LED4 GREEN-LED2 RED-LED3

Page 50

Troubleshooting

 

Name of running status

Yellow light

Red light

Green light

Indoor unit display

 

 

 

 

 

 

1

Compressor start

Blink once

 

 

 

 

 

 

 

 

 

2

Defrosting

Blink twice

 

 

H1

 

 

 

 

 

 

3

Anti-freezing protection

Blink three times

 

 

E2

 

 

 

 

 

 

4

IPM protection

Blink four times

 

 

H5

 

 

 

 

 

 

5

Overcurrent protection

Blink five times

 

 

E5

 

 

 

 

 

 

6

Overload protection

Blink six times

 

 

H4

 

 

 

 

 

 

7

Air exhaust protection

Blink seven times

 

 

E4

 

 

 

 

 

 

8

Overload protection

Blink eight times

 

 

H3

 

 

 

 

 

 

9

Limited frequency (current)

 

Blink once

 

 

 

 

 

 

 

 

10

Limited frequency (Air exhaust)

 

Blink twice

 

 

 

 

 

 

 

 

11

Limited frequency (overload)

 

Blink three times

 

 

 

 

 

 

 

 

12

Limited frequency (anti-freezing)

 

Blink four times

 

 

 

 

 

 

 

 

13

Outdoor unit ambient sensor malfunction

 

Blink five times

 

F3

 

 

 

 

 

 

14

Outdoor unit tube temp. sensor malfunction

 

Blink six times

 

F4

 

 

 

 

 

 

15

Outdoor air exhaust sensor malfunction

 

Blink seven times

 

F5

 

 

 

 

 

 

 

 

 

 

 

 

16

Achieve the temperature of unitstartsup

 

Blink eight times

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

Communication is normal

 

 

Blink continuously

 

 

 

 

 

 

 

18

Communication malfunction

 

 

OFF

E6

 

 

 

 

 

 

19

Overload sensor malfunction

 

Blink nine times

 

H3

 

 

 

 

 

 

20

Low voltage protection

Blink twelve times

 

 

PL

 

 

 

 

 

 

21

High voltage protection

Blink thirteen times

 

 

PH

 

 

 

 

 

 

22

Indoor ambient sensor malfunction

 

 

 

F1

 

 

 

 

 

 

23

Indoor tube temperature sensormalfunction

 

 

 

F2

 

 

 

 

 

 

24

Normal cooling or norminal heating

 

 

 

P1

 

 

 

 

 

 

25

Max. cooling or max. heating

 

 

 

P2

 

 

 

 

 

 

26

Interim cooling or interim heating

 

 

 

P3

 

 

 

 

 

 

27

Min. cooling or Min. heating

 

 

 

P0

 

 

 

 

 

 

YELLOW-LED4

GREEN-LED2

RED-LED3

50

Image 50
Contents Split Type Room AIR Conditioner Wall Mounted Type Table of Contents Model and product code Summary and features Important Safety Information Refrigeration System Repair Hazards Property Damage Hazards Specifications 115 MR09C1H MR12C1H Appending date Expanded capacity data tables for both cooling and heating Operation Characteristic Curve 09KUnits Construction Views Refrigerant System Diagram Electrical wiring Electrical DateCooling Models TOP View Bottom View Bottom View Remote Control Operations Function and ControlAuto Timer on Displayed. If the light is tunrned off Disappears Replacement of Batteries Description of Each Control Operation Function and Control Function and Control Setting+ 2, medium speed Tring ≤ Tsetting 2, low speed P2 Maximum cooling and heating 3-minutes Standby Detection of temperature sensor malfunctionFrequency Control Compressor Protection FunctionFreeze-up Protection Control Discharge Pipe ControlInput Current Control Detail Conditions for Start Controlling Fan Control Tap Control in indoor/outdoor unit silent operationImportant Notices Ground requirements Installation dimension diagram Boring Piping Hole Installing Indoor Unit Electric wiring Installing Outdoor UnitCheck after Installation Check after Installation and Operation TestInstallation and Maintenance of Healthy FilterOptional Installation of Healthy FilterTroubleshooting Can not start up Malfunction of four-way valve Is not on, then replace the protector Adjust support washer of compressor, Troubleshooting YELLOW-LED4 GREEN-LED2 RED-LED3 Analysis or processing of some of the malfunction display How to Check simply the main part Troubleshooting Comp Page AP1 Troubleshooting Is stop time of the compressor longer than 3 minutes? Minutes after the complete unit is powered off Start If the fault is eliminated? Troubleshooting Flow chart for outdoor communitcation circuit detecting Troubleshooting Guide Troubleshooting Guide Temp Resistance 2-way, 3-way Valve Appearance Way Valve Liquid SideProcedure Close Close Open Close Balance Refrigerant of the 3-way Valve Procedure EvacuationGas Charging After EvacuationRemoval Procedure Removal Procedure Removal Procedure Removal Procedure of Outdoor Unit Removal Procedure Removal Procedure MW09C1H / MW12C1H Exploded Diagram MW09C1H Parts List MW12C1H Parts List MR09C1H Exploded Diagram MR09C1H Parts List MR12C1H Exploded View MR12C1H Parts List Page Friedrich AIR Conditioning CO