Friedrich MR09C1H, MW09C1H, MR12C1H manual MW12C1H Parts List

Page 82

MW12C1H Parts List

NO.

FPN

Part Description

1

69700100

Filter Sub-Assy

2

69700141

Front Case Sub-Assy

3

69700142

Front Case

4

69700103

Evaporator Assy

5

69700104

Evaporator Support

6

69700105

Guide Louver

7

69700106

Axile Bush (guide louver)

 

 

 

9

69700108

Helicoid tongue

10

69700109

Air Louver 2

11

69700110

Air Louver 1

12

69700111

Left Axile Bush

13

69700112

Bearing cushion rubber base

14

69700113

O-Gasket sub-assy of Bearing

15

69700114

Cross Flow Fan

16

69700115

Water Tray Glue Plug

17

69700116

Wall Mounting Frame

18

69700117

MotorPressPlate

19

69700118

Pipe Clamp

20

69700119

Drainage Pipe

21

69700120

Cable Cross Plate

22

69700121

Rear Case assy

23

69700122

Fan Motor

24

69700123

Motor MP24AA

25

69700124

Crank

26

69700125

Display Board

27

69700126

Ambient Temperature Sensor

28

69700127

Transformer

29

69700143

Electric Box Assy

30

69700129

Electric Box

31

69700130

4-bit Terminal Board

32

69700131

Main Board

33

69700144

Jumping Connector

34

69700133

Tube Sensor (20K black)

35

69700134

Electric Box Cover1

36

69700135

Shield cover of Electric Box sub-assy

37

69700145

Remote Controller

38

69700137

Electric Box Cover2

39

69700138

Screw Cover

40

69700139

Front panel D1

41

69700140

Front Panel Sub-Assy

82

Image 82
Contents Split Type Room AIR Conditioner Wall Mounted Type Table of Contents Model and product code Summary and features Important Safety Information Refrigeration System Repair Hazards Property Damage Hazards Specifications 115 MR09C1H MR12C1H Appending date Expanded capacity data tables for both cooling and heating Operation Characteristic Curve 09KUnits Construction Views Refrigerant System Diagram Electrical wiring Electrical DateCooling Models TOP View Bottom View Bottom View Remote Control Operations Function and ControlAuto Timer on Displayed. If the light is tunrned off Disappears Replacement of Batteries Description of Each Control Operation Function and Control Function and Control Setting+ 2, medium speed Tring ≤ Tsetting 2, low speed P2 Maximum cooling and heating 3-minutes Standby Detection of temperature sensor malfunctionFrequency Control Compressor Protection FunctionInput Current Control Discharge Pipe ControlFreeze-up Protection Control Detail Conditions for Start Controlling Fan Control Tap Control in indoor/outdoor unit silent operationImportant Notices Ground requirements Installation dimension diagram Boring Piping Hole Installing Indoor Unit Electric wiring Installing Outdoor UnitCheck after Installation Check after Installation and Operation TestInstallation and Maintenance of Healthy FilterOptional Installation of Healthy FilterTroubleshooting Can not start up Malfunction of four-way valve Is not on, then replace the protector Adjust support washer of compressor, Troubleshooting YELLOW-LED4 GREEN-LED2 RED-LED3 Analysis or processing of some of the malfunction display How to Check simply the main part Troubleshooting Comp Page AP1 Troubleshooting Is stop time of the compressor longer than 3 minutes? Minutes after the complete unit is powered off Start If the fault is eliminated? Troubleshooting Flow chart for outdoor communitcation circuit detecting Troubleshooting Guide Troubleshooting Guide Temp Resistance 2-way, 3-way Valve Appearance Way Valve Liquid SideProcedure Close Close Open Close Balance Refrigerant of the 3-way Valve Procedure EvacuationGas Charging After EvacuationRemoval Procedure Removal Procedure Removal Procedure Removal Procedure of Outdoor Unit Removal Procedure Removal Procedure MW09C1H / MW12C1H Exploded Diagram MW09C1H Parts List MW12C1H Parts List MR09C1H Exploded Diagram MR09C1H Parts List MR12C1H Exploded View MR12C1H Parts List Page Friedrich AIR Conditioning CO