Friedrich MR12C1H, MW12C1H, MW09C1H manual Analysis or processing of some of the malfunction display

Page 51

Troubleshooting

Analysis or processing of some of the malfunction display:

1. Compressor discharge protection

Possible reasons: shortage of refrigerant; blockage of air filter; poor ventilation or air flow short pass for condenser; the system has noncondensing gas (such as air, water etc.); blockage of capillary assy (including filter); leakage inside four-way valve causes incorrect operation; malfunction of compressor; malfunction of protection relay; malfunction of discharge sensor; outdoor temperature too high.

Processing method: refer to the malfunction analysis in the above section.

2. Low voltage over current protection

Possible reason: Sudden drop of supply voltage.

3.Communication malfunction

Processing method:Check if communication signal cable is connected reliably.

4.Sensor openo rs hort circuit

Processing method: Check whether sensor is normal, connected with the corresponding position on the controller and if damage lf lead wire is found.

5.Compressor overload protection

Possible reasons: insufficient or too much refrigrant; blockage of capillary and increase of suction temp.; improper running of compressor, burning in or stuck of bearing, damage of discharge valve; malfunctioning of protector.

Processing method: adjust refrigerant amount; replace the capillary; replace the compressor; use universal meter to check if the contactor of compressor is fine when it is not overheated, if not replace the protector.

6.System malfunction

i.e.overload protection.When tube temperature (Check the temperature of outdoor heat exchanger when cooling and check the temperature of indoor heat exchanger when heating) is too high, protection will be activated.

Possible reasons: Outdoor temperature is too high when cooling; insufficient outdoor air circulation; refrigerant flow malfunction.

please refer to the malfunction analysis in the previous section for handling method .

7.IPM module protection

Processing method:Once the module malfunction happens,if it persists for a long time and can not be self- canceled, cut off the power and turn off the unit,and then re-energize the unit again after about 10 min. After repeating the procedure for sever times, if the malfunction still exists, replace the module.

51

Image 51
Contents Split Type Room AIR Conditioner Wall Mounted Type Table of Contents Model and product code Summary and features Important Safety Information Refrigeration System Repair Hazards Property Damage Hazards Specifications 115 MR09C1H MR12C1H Appending date Expanded capacity data tables for both cooling and heating Operation Characteristic Curve 09KUnits Construction Views Refrigerant System Diagram Electrical Date Electrical wiringCooling Models TOP View Bottom View Bottom View Function and Control Remote Control OperationsAuto Timer on Displayed. If the light is tunrned off Disappears Replacement of Batteries Description of Each Control Operation Function and Control Function and Control Setting+ 2, medium speed Tring ≤ Tsetting 2, low speed P2 Maximum cooling and heating Compressor Protection Function Detection of temperature sensor malfunctionFrequency Control 3-minutes StandbyDischarge Pipe Control Input Current ControlFreeze-up Protection Control Detail Conditions for Start Controlling Tap Control in indoor/outdoor unit silent operation Fan ControlImportant Notices Ground requirements Installation dimension diagram Boring Piping Hole Installing Indoor Unit Installing Outdoor Unit Electric wiringCheck after Installation and Operation Test Check after InstallationInstallation of Healthy Filter Installation and Maintenance of Healthy FilterOptionalTroubleshooting Can not start up Malfunction of four-way valve Is not on, then replace the protector Adjust support washer of compressor, Troubleshooting YELLOW-LED4 GREEN-LED2 RED-LED3 Analysis or processing of some of the malfunction display How to Check simply the main part Troubleshooting Comp Page AP1 Troubleshooting Is stop time of the compressor longer than 3 minutes? Minutes after the complete unit is powered off Start If the fault is eliminated? Troubleshooting Flow chart for outdoor communitcation circuit detecting Troubleshooting Guide Troubleshooting Guide Temp Resistance Way Valve Liquid Side 2-way, 3-way Valve AppearanceProcedure Close Close Open Close Balance Refrigerant of the 3-way Valve Evacuation ProcedureAfter Evacuation Gas ChargingRemoval Procedure Removal Procedure Removal Procedure Removal Procedure of Outdoor Unit Removal Procedure Removal Procedure MW09C1H / MW12C1H Exploded Diagram MW09C1H Parts List MW12C1H Parts List MR09C1H Exploded Diagram MR09C1H Parts List MR12C1H Exploded View MR12C1H Parts List Page Friedrich AIR Conditioning CO