Friedrich Comprehensive Parts List for the MR12C1H Air Conditioner

Page 86

MR12C1H Parts List

NO.

FPN

Part Description

1

69700000

Mesh Enclosure

2

69700031

Front Panel

3

69700002

Axial-flow Fan

4

69700003

Motor FW30G-ZL

5

69700017

Tube Sensor (20K black)

6

69700016

Temperature Sensor for Discharge Gas

7

69700021

Sensor

8

69700032

Motor suport spot welding sub-assy

9

69700033

Condenser Assy

10

69700019

Inhalation Tube

11

69700025

Top Cover Plate

12

69700034

Rear Grill

13

69700035

Discharge Tube

14

69700015

Magnet Coil

15

69700036

Right Side Plate

16

69700011

Valve Support

17

69700027

Electric box cover sub-assy

18

69700029

Electric Box Assy

19

69700020

Overload Protector

20

69700006

Compressor Gasket

21

69700037

Drainage Plug

22

69700010

Cut-off Valve (3/8)

23

69700009

Cut-off Valve (1/4)

24

69700007

Compressor C-6RZ110H1A

25

69700038

Clapboard Sub-Assy

26

69700039

Chassis Sub-assy

27

69700028

Main Board

86

Image 86
Contents Split Type Room AIR Conditioner Wall Mounted Type Table of Contents Model and product code Summary and features Important Safety Information Refrigeration System Repair Hazards Property Damage Hazards Specifications 115 MR09C1H MR12C1H Appending date Expanded capacity data tables for both cooling and heating Operation Characteristic Curve 09KUnits Construction Views Refrigerant System Diagram Electrical wiring Electrical DateCooling Models TOP View Bottom View Bottom View Remote Control Operations Function and ControlAuto Timer on Displayed. If the light is tunrned off Disappears Replacement of Batteries Description of Each Control Operation Function and Control Function and Control Setting+ 2, medium speed Tring ≤ Tsetting 2, low speed P2 Maximum cooling and heating 3-minutes Standby Detection of temperature sensor malfunctionFrequency Control Compressor Protection FunctionFreeze-up Protection Control Discharge Pipe ControlInput Current Control Detail Conditions for Start Controlling Fan Control Tap Control in indoor/outdoor unit silent operationImportant Notices Ground requirements Installation dimension diagram Boring Piping Hole Installing Indoor Unit Electric wiring Installing Outdoor UnitCheck after Installation Check after Installation and Operation TestInstallation and Maintenance of Healthy FilterOptional Installation of Healthy FilterTroubleshooting Can not start up Malfunction of four-way valve Is not on, then replace the protector Adjust support washer of compressor, Troubleshooting YELLOW-LED4 GREEN-LED2 RED-LED3 Analysis or processing of some of the malfunction display How to Check simply the main part Troubleshooting Comp Page AP1 Troubleshooting Is stop time of the compressor longer than 3 minutes? Minutes after the complete unit is powered off Start If the fault is eliminated? Troubleshooting Flow chart for outdoor communitcation circuit detecting Troubleshooting Guide Troubleshooting Guide Temp Resistance 2-way, 3-way Valve Appearance Way Valve Liquid SideProcedure Close Close Open Close Balance Refrigerant of the 3-way Valve Procedure EvacuationGas Charging After EvacuationRemoval Procedure Removal Procedure Removal Procedure Removal Procedure of Outdoor Unit Removal Procedure Removal Procedure MW09C1H / MW12C1H Exploded Diagram MW09C1H Parts List MW12C1H Parts List MR09C1H Exploded Diagram MR09C1H Parts List MR12C1H Exploded View MR12C1H Parts List Page Friedrich AIR Conditioning CO